Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: None, Semi-Standard, Body Size 10: R (Flow Direction: Right to Left), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: 1C (1 + C), Semi-Standard 2: Standard
Body Size: 20, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 2J (2 + J), Semi-Standard 2: Standard
Body Size: 20, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: CJ (C + J), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 6 (Nylon Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port Size: 01 (1/8), Option: Standard, Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: None, Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: C (Bowl Guard), Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 01 (1/8), Option: w/o Mounting Option, w/o Pressure Gauge, Semi-Standard: 1Y (1 + Y)
Body Size: 20, Thread: None (Rc: for Body Size 20, 30, 40, 50, 60; M5: for Body Size 10), Port Size: 01 (1/8), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 6R (6 + R), Semi-Standard 2: Standard
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: 01 (Rc1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration
Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult P/A regarding other voltages.
Going to Great Lengths with Polyurethane Tubing L G O B A S L N O P I R T O U D L O U S C T L S A B O G L Polyurethane Tubing Series TIUB & TU SMC Offers a Rainbow of Tubing Types, Colors, Sizes and Lengths Polyurethane has 8 Quick Ship colors, equalling 336 part numbers, stocked on the shelf and ready to ship in all available sizes and lengths.
Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AME650 is obtained when the max. flow line is above the point of intersection A in the graph. Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.
NPN PNP 80 mA DC28 V NPN1 V (80 mA ) PNP1.5 V (80 mA ) 5 7 0.25 s/0.5 s/1 s/2 s/5 s 6 7 0.25 s/0.5 s/1 s/2 s/5 s 15 V 1 k 420 mA 600 2 (4 7 2 /6 11 ) 5 / 12 DC24 V10 45 mA () 64 No.LFE*-OMY0008 LFE1 LFE2 LFE3 9 IP65 050 () 3585R.H.() CE RoHS PPSFKM 3/8(10 A) 1/2(15 A) 3/4(20 A) 1(25 A) () 8 340 g 400 g 520 g 680 g 166 [] 20L/min 3(69 []) 4OFF (2 5 ) 5 100 (24 5 100
Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
(Nm) L(mm) MHM-16D M3x0.5 0.63 6 MHM-25D M4x0.7 1.5 8 MHM-32D M5x0.8 3 10 MHM-50D M6x1 5.2 12 (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 -7- 2-3. 40 2-4. () 5 5 P-01-11 -8- 2-5. 1.52 2-6. 1 ()ISO VG320 (SDS) -9- 2-7. 1) 1) 2) 3) 12mm -10- 2 C3 C1 C2: C3 D-M9V D-M9WV D-M9AV D-M9 D-M9W D-M9A D-P3DWA A B E G A B E G L A B E G L D F H MHM-16D 9.1 9.1 5.6 4.6 8.1 12.8 11
A low valve closing speed relieves the water hammer. Operation < Valve opened > When the coil u is energized the opened pilot A closes, the pressure in the pressure action chamber B rises and the main valve C closes. < Valve closed > When the coil u is not energized, the closed pilot valve A opens, the pressure in the pressure action chamber B drops and the main valve C opens.
Select the point of contact A of inlet pressure and max. air capacity in the graph. 2. AMF650 is obtained when the max. flow line is above the point of intersection A in the graph. HA AT ID Max. air flow rate (m3/min (ANR)) AMG Note) Make sure to select a model that has the maximum flow rate line above the obtained intersecting point.