Actuator mounting A Model Bolt size Maximum tightening torque [Nm] Amm) mm LEKFS16 M3 0.63 3.5 23.5 LEKFS25 M4 1.5 4.5 24 LEKFS32 M5 3.0 5.5 30 LEKFS40 M6 5.2 6.6 31 4. When mounting the actuator, leave a gap of 40mm or more to allow for bending of the actuator cable. 20 - 3.4 Precaution on maintenance Warning 1.
Mount with the set screws M3 size (2 pcs.) supplied for direct installation. The required tightening torque of the mounting screws is 0.5 to 0.7 Nm. Mounting with panel mount adapter Panel mount adapter + Front protective cover (Model: ZS-39-D) -15No.PS-OMM0005-J Removal and mounting on DIN rail It is necessary to prepare a DIN rail adapter for the mounting on the DIN rail.
Mounting with bracket Fix the bracket to the Pressure switch with the set screws M3 x 5 L (2 pcs.) supplied. The required tightening torque is 0.5 to 0.7 Nm.
VBA-OM-L007-E The elbow for silencer (option) can be used only for mounting a silencer OPERATION MANUAL VBA-M3 Handling Precautions to the exhaust port. Do not use it for the IN port and the OUT port. Prepare piping separately to exhaust remotely by connecting pipes to the exhaust port. To ensure safe and optimum operation, confirm the products specifications before use.
Every air cylinder intended for use or mounting in Japan, with the gauge pressure of 0.2 MPa or more and the cylinder internal capacity of 0.04 m3 and more, or with the cylinder inside diameter of 200 mm dia. or more and the stroke of more than 998 mm falls within the scope of the second class pressure vessel regulations.
Bore size Hexagon socket head Appropriate tightening (mm) cap screw (mm) torque (Nm) 6, 10 M3 1.0810% 16 M4 2.4510% Do not use compressed air containing a lot of condensate, which 20, 25 M5 5.1010% can cause the operating failure of the product and other pneumatic 32 M6 8.0410% equipment. Ensure that fluid and ambient temperature are within the specified range.
Connection of fittings When screwing fittings into valves, tighten as follows. (1) Follow the procedures below when installing an SMC fitting, etc. 1) M3 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn. As a reference value, tightening torque is 0.4 to 0.5Nm.
Connection of fittings When screwing fittings into valves, tighten as follows. (1) Follow the procedures below when installing an SMC fitting, etc. 1) M3 types After tightening the fitting by hand, use a wrench to tighten the fitting an additional approximately 1/4 turn.
SPECIFICATIONS Model AFM20-A AFM30-A AFM40-A AFM40-06-A Port size 1/81/4 1/43/8 1/43/81/2 3/4 Fluid Air Ambient and fluid -5 60 (Should be no freezing) temperature Proof pressure Max. operating pressure 1.5 MPa 1.0 MPa Min. operating pressure 0.05 MPa 0.3 m (FILTRATION EFECIENCY 99.9%) Filtration MAX.1.0 mg/m3(ANR)(0.008ppm) Note1 Note2 Oil mist density at the out side 1100 Flow rateLminANR
(Applicable bolt size is M3) These grooves can be used for firmly fixing the tying bands of lead wires of the auto switch, etc., and also terminal boards, etc., to the main body of the cylinder. When the terminal block is fixed on a cylinder directly. 6 12. Piping 12-1. Attention in piping 1) Use clean air.
Mounting dimension on side face Size Bolt Tap depth Size Bolt 05 M4X0.7 5 Body tap Body through hole 1 M5X0.8 6 05 M4X0.7 M3 1 M5X0.8 M4 Piping Fig. (4) and Table (8) show port position and size. A port A port B port B port Side port Front port Fig.4 Port position 24 - Table 8. Port size .
50 63,CF114 80 Actuating type Normally closed (Pressurize to open , spring seal) Fluid Vacuum of inert gas Operating temperature oC 5 to 60 (High temperature type:5 to 150) Operating pressure Pa(abs) Atmospheric pressure to 1 x 10-6 Conductance l/s Note 2 5 14 45 80 160 200 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Leakage Pa m3
MB1 Bore size [mm] Thread size Pulling force Stroke [mm] 32 M2.5 x 0.45 x 25 L 4.9 N 2 40, 50, 63 M3 x 0.5 x 30 L 10 N 3 80, 100 M5 x 0.8 x 40 L 24.5 N 3 Before starting operation, supply air to side without locking mechanism as figure above, (or side without locking the piston rod for models with locking at both ends.) Otherwise, lock may not be released. (Refer to Release of lock.)
Note 50 63 32 40 Bore size (mm) Action Double acting Reed switch D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W Solid state switch D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F78AVL D-F79F Fluid Air 0.1 to 0.6 MPa Operating pressure Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut. 5 to 60C Ambient and fluid temperature 32, 40 50, 63 BQ-2 Lubrication Not required 3 to
Material Case Note 1 Electrolytic polishing (Interior/Exterior) SFB10-02 Stainless steel 316 Cover 2 0.1 Clean gas filter For SFB10 PTFE membrane Element 3 Clean gas strainer For SFB20 Stainless steel 316 sintered metal O-ring 4 FKM Hexagon socket head cap screw 5 M3 Max. flow rate line Stainless steel 304 Pressure drop MPa Inlet pressure Bracket 6 0.3 MPa 0.01 0.1 MPa 0.7 MPa 0.001 0.5
Manufacturer M4 x 0.7 M3 x 0.5 Thread size 32.5 21.5 Effective thread length (mm) 8 6 Quantity 2 4 P.C.D. 46 45 Motor mounting area When mounting a coupling on the motor, mount it within the dimensional range shown on the left. A A B Section BB P.C.D.
Button head screw (M2.6 x 10) Tightening torque: 0.4 to 0.5Nm + Washer Brown lead wire Proximity switch Internal circuit Output Black lead wire Switch mounting bracket Hexagon nut Blue lead wire Thin head screw (M3 x 4) Tightening torque: 0.38 to 0.42Nm Round head screw (M2.5 x 5) GXL-8FU(B)(I) Tightening torque: 0.38 to 0.42Nm + Switch plate Spring washer Brown lead wire Switch plate Main
1 Stainless steel M4 x 0.7 x 8 Cross-recessed head cap screw Cross-recessed head cap screw Steel wire M4 x 0.7 x 8 M3 x 0.5 x 6 !0 !2 NBR 14284 O-ring 143021 !1 15-9-41 3 Dimensions AS2000E/3000E 2-port size L7 Max. Min.
Series ASV Speed Exhaust Controller Size: M3, M5, 1/8, 1/4, 3/8 . How to Order . Construction. Dimensions . Check Valve Series AK. Series AK Check Valve. Specifications. How to Order . Construction. Dimensions .
Note 50 63 32 40 Bore size (mm) Action Double acting Reed switch D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W Solid state switch D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F78AVL D-F79F Fluid Air 0.1 to 0.6 MPa Operating pressure Switch mounting screw (M3 x 0.5 x 10l) Switch spacer Switch mounting nut. 5 to 60C Ambient and fluid temperature 32, 40 50, 63 BQ-2 Lubrication Not required 3 to