Recommended torque: 12 to 14 Nm. 231 MR Unit (Regulator with Mist Separator) AMR3000 to 6000 Replacement Procedure is P.448 Construction !1 t OUT IN u MC cartridge element Flow hole A Separation element i y Auto-drain type o !0 r Port size 1/4 Drain The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series AMR.

Recommended torque: 12 to 14 Nm. 231 MR Unit (Regulator with Mist Separator) AMR3000 to 6000 Replacement Procedure is P.448 Construction !1 t OUT IN u MC cartridge element Flow hole A Separation element i y Auto-drain type o !0 r Port size 1/4 Drain The numbers are the same as the "Construction" of the Best Pneumatics No.5 Series AMR.

Humidity and liquid water Oil Maximum number of particles per cubic meter as a function of particle size d [mm] Mass concentration Cp Pressure dew point Concentration of liquid water Cw Concentration of total oil 0.1 < d 0.5 0.5 < d 1.0 1.0 < d 5.0 [mg/m3] [C] [g/m3] [mg/m3] 0 As specified by the equipment user or supplier and more stringent than class 1 1 20 400 10 70 0.01 2 40 6000

rate (l/min (ANR)) Thread type Nil N F Rc NPT G AK4000-03/-04 AK6000-06/-10 Port size 0.5 MPa 0.5 MPa Port size Applicable series AK2000 AK2000/4000 AK4000 AK4000 AK6000 AK6000 Inlet pressure: 0.1 MPa Inlet pressure: 0.1 MPa 0.3 MPa 0.3 MPa 0.7 MPa 0.7 MPa 01 02 03 04 06 10 1 8 1 4 3 8 1 2 3 4 1 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 15-14-1 Series AK Construction AK2000 AK4000/6000

(Page 47) WH1 (Window comparator hysteresis) Setting of OUT1 hysteresis (Window comparator) 5 R/W U16 400 Y Settable values 0x0 to 0x1770 (0 to 6000) 6 R/W dt1 (Delay time) U16 0 Y Setting of OUT1 delay time 10 ms increment -43No.PF-OMX0007-A Product individual parameters (continued) Data Data Index Sub Access Initial value type storage 1 Parameter Set value 4 Remarks index 2 3 dec hex 0:

. -29No.EX-OMN0009-G Network communication specifications Item Specifications Protocol PROFIBUS DP (EN50170, EN50254) Transmission speed 9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, 12000 (kbps) Device type DP slave EX260-SPR1/-SPR2/-SPR5/-SPR6 32 outputs Number of outputs EX260-SPR3/-SPR4/-SPR7/-SPR8 16 outputs EX260-SPR1/-SPR2 Smc_1430.gsd EX260-SPR3/-SPR4 Smc_1431.gsd Configuration

AMH250 AMH350 AMH450 AMH550 AMH650 AMH850 AMH150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at pressure of 0.7 MPa. It varies depending on operating pressure.

PFA703H--28 PFA703H--68 PFA706H--28 PFA706H--68 PFA703H--29 PFA703H--69 PFA706H--29 PFA706H--69 3000 3000 150 150 6000 6000 300 300 PFA712H--28 PFA712H--68 PFA712H--29 PFA712H--69 12000 12000 600 600 103 &RXUWHV\RI6WHYHQ(QJLQHHULQJ,QF5\DQ:D\6RXWK6DQ)UDQFLVFR&$ *HQHUDO For Water Digital Flow Switch Series PFW How to order PFW7 20 03 27 Integrated display type Flow rate range 0.5 to 4l/min

and input devices are connected ) Communication method Protocol: Dedicated for SMC Speed: 750kbps Number of branches for input/output 4 branches ( 16 points/branch ) for input 4 branches ( 16 points/branch ) for output Loop resistance 110 /km Capacity 30pF/m or less Impedance 135 165 Cable length [m] 1200 1000 400 200 100 Transmission rate [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000

(page 77 to 78) Y U16 0x0190 5 R/W (400) dtH2 (OUT2 delay time at ON) Setting of OUT1 delay time at ON. 0x0 ~ 0x1770 (0 ~ 6000) 0.01 s increment Y U16 0x0 6 R/W (0) Setting of OUT1 delay time at OFF. 0x0 ~ 0x1770 (0 ~ 6000) 0.01 s increment dtL2 (OUT2 delay time at OFF) Y U16 0x0 7 R/W (0) Setting of digital filter. 0x0 ~ 0x0BB8 (0 ~ 3000) 0.01 s increment 0x070B (1803) 0 R/W FiL (Digital

PAT. 17-5-172 33 Flow Switch Series PF, IF For Air Digital Flow Switch/Series PFA Display integral type Output specification Port size (Rc, NPT, G) Flow rate range (l/min) Separate type Display Sensor Switch output Analog output Accumulated pulse output PFA710 750 711 721 751 703H 706H 712H PFA510 550 511 521 551 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 6000 to

To Travel amount per 1 command pulse (P=1m) by actuator lead (L = 6mm) and pulley ratio (n1/n2 = 1/1) = 1 1048576 1 1000 Pn210 Pn20E 1 6 1/1 = 1048576 Pn210 Pn20E 6 1000 1 = 1048576 Pn210 Pn20E 6000 1 = 65536 Pn210 Pn20E 375 1 *1 For pulley ratio, refer to Lead of LECYM Operation Manual (Simplified Edition),section 4.4.1.

7000 0.0 0.0 0 1000 2000 5000 6000 3000 4000 0.8 1.0 1.2 0.4 0.6 SRF Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Supply pressure (MPa) VCHR ITV ITV IC ITVX PVQ VEF VEP VER VEA VY1 VBA VBAT AP100 823 Series ITV1000/2000/3000 Construction ITV1000 Main Component Parts No.

Filter P.402 AFM Modular Type Mist Separator P.402 AFD Modular Type Micro Mist Separator P.404 AR Modular Type Regulators P.412 AL Modular Type Lubricators P.420 AW Modular Type Filter Regulators P.431 ARG Modular Type Regulator with Built-in Pressure Gauge P.437 AWG Modular Type Filter Regulator with Built-in Pressure Gauge P.444 AR425 to 925 Pilot Operated Regulator P.448 AMR3000 to 6000

Filter P.402 AFM Modular Type Mist Separator P.402 AFD Modular Type Micro Mist Separator P.404 AR Modular Type Regulators P.412 AL Modular Type Lubricators P.420 AW Modular Type Filter Regulators P.431 ARG Modular Type Regulator with Built-in Pressure Gauge P.437 AWG Modular Type Filter Regulator with Built-in Pressure Gauge P.444 AR425 to 925 Pilot Operated Regulator P.448 AMR3000 to 6000

To Travel amount per 1 command pulse (P=1m) by actuator lead (L = 6mm) and pulley ratio (n1/n2 = 1/1) = 1 1048576 1 1000 Pn210 Pn20E 1 6 1/1 = 1048576 Pn210 Pn20E 6 1000 1 = 1048576 Pn210 Pn20E 6000 1 = 65536 Pn210 Pn20E 375 1 *1 For pulley ratio, refer to Lead of LECYU Operation Manual (Simplified Edition),section 4.4.1.

~ 5200) ISE71: 0x02E2 ~ 0x1450 (738 ~ 5200) Setting range ISE70: 0x03E8 ~ 0x0CEE WH2 (Window comparator hysteresis) Setting of OUT2 hysteresis (window comparator hysteresis) U16 1400 Y 1026 0x0402 0 R/W (1000 ~ 3310) ISE71: 0x03E8 ~ 0x0C9E (1000 ~ 3231) Setting of OUT2 delay time at ON 0.01 s increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 ~ 0x1770 (0 ~ 6000

10003310) ISE75G0x03E80x0C85 (10003205) WH1 (Upper limit of window comparator) Setting of OUT1 hysteresis (window comparator hysteresis) ISE76G0x03E80x0C80 1016 0x03F8 0 R/W U16 1400 Y (10003200) ISE77G0x03E80x0C80 (10003200) ISE78G0x03E80x0C80 (10003200) Setting of OUT1 delay time at ON 0.01 s increment 1017 0x03F9 0 R/W dtH1 (Delay time at ON) U16 0 Y Settable values 0x0 ~ 0x1770 (0 ~ 6000

E3 ] 23 [AL. 25][AL. 92][AL. 9F] 12.1 1 ON/OFF CYC LS LS0 CYC0 (6 V 3.4 V) LECMR-BAT6V1SET MR-BAT6V1SET (1 pulse/rev) 1 12 2 12. 12.2 (1) LEC-MR-BAT6V1SET 2CR17335A() [V] 6 [mAh] 1650 [] 055 [] 055 [g] 1.2 1ppm Class 9 ( 2g) () 90%RH() [g] 34 32767rev (1) [r/min] 6000 (6000r/min0.2s) (2) 2(20) 2.9(25%20) (4) (3) 5 1. 3000r/min 2.

output set value (upper limit of window comparator) 1025 0x0401 0 R/W U16 3400 Y (8005200) WH2 (Window comparator hysteresis) Setting range ISE79S0x03E80x0C80 Setting of OUT2 hysteresis (window comparator hysteresis) 1026 0x0402 0 R/W U16 1400 Y (10003200) Setting of OUT2 delay time at ON 0.01 s increment 1027 0x0403 0 R/W dtH2 (Delay time at ON) U16 0 Y Settable values 0x0 ~ 0x1770 (0 ~ 6000