SMC Corporation of America
Elite Part Number Search
Search Results "MHKL2-20C"

[ANR] Indicates the flow rate converted to a volume under standard conditions: 20C, 1 atm (atmosphere), 65%RH [Nl/min] Indicates the flow rate converted to a volume under normal conditions: 0C, 1 atm (atmosphere). External input Can be selected from accumulated value external reset, auto-shift and auto-shift zero.

190 220 AF-A [L/min (ANR)] 7 25 55 Oil capacity (cm3) Recommended lubricant Bowl material Bowl guard Weight (kg) 135 AR-A Class 1 turbine oil (ISO VG32) Polycarbonate AL-A 0.07 Semi-standard 0.11 Standard 0.52 0.24 0.47 1.06 1.13 AW-A Note) The flow rate is 5 drips or greater/min under the following conditions: Inlet pressure of 0.5 MPa; Class 1 turbine oil (ISO VG32); Temperature at 20C

(Circulating fluid OUT is directly connected with IN) 1500 6 Output Cutoff Alarm a contact 1500 Cooling capacity (Set Temp. 20C and Facility water Temp. 20C, 10L/min) The product is operated at high voltage.

Symbol Nil 10 mm Coating color White 1 Mass lbs (kg) 119 (54) 137 (62) 258 (117) 271 (123) Compliant standards UL, CSA Note 1) ANR is under the conditions of 68F (20C) at atmospheric pressure and relative humidity of 65%. Note 2) Air flow capacity for each outlet air pressure dew point is indicated. Note 3) Install a circuit breaker with a sensitivity of 30 mA.

size 5/32" 3/16" 5/16" 3/8" 1/2" 1/4" , 5/32" 5/16" 3/8" Controlled flow Free flow Critical pressure ratio 20 100 180 230 260 390 460 660 790 920 1580 1710 Flow rate L/min (ANR) Sonic conductance dm3/(sbar) 0.06 0.28 0.5 0.64 0.72 1.1 1.8 2.2 4.4 4.8 1.3 2.6 0.2 0.2 0.25 0.3 0.25 0.25 Controlled flow 0.4 0.4 0.2 0.3 0.2 0.3 Free flow Note 1) Flow rate values are measured at 0.5 MPa and 20C

AS1002F 3.2, 4, 6 1/8", 5/32" 1/4" 100 1.5 AS2002F 4 AS3002F AS2052F AS4002F 12 Series Metric size 2 6 8 1/4" 5/16" 460 7 6 10 8 10, 12 6 JIS symbol Inch size Tube O.D. 5/16" 5/32" 1/4" 1/4" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 660 10 290 4.5 390 6 920 14 920 14 1390 21 20 0.3 130 2 230 3.5 Controlled flow (Free flow) Effective area (mm2) Note) Flow rate values are measured at 0.5 MPa and 20C

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

Based on condition y; IDFS11E is selected as the model to process an air flow larger than 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. 4 4 Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Data A: Correction Factor for Temperature (Series IDUS) Inlet air temp. (C) Outlet air press. dew point (C) Ambient temp.

Flow at 20C, atmospheric pressure, and 65% of relative humidity. The compressed air quality class on the inlet side is [1:4:2]. Note 3) Based on ISO8573-1:2010 Compressed air Part1: Contaminants and purity classes. -7- 4.

Polyurethane Flat Tubing Series TFU Compact piping possible Model/Specifications K TFU 0425B-2 2 cores TFU 0805B-3 3 cores 4 6 8 2.5 4 5 TFU 0425B-3 3 cores TFU 0604B-2 2 cores TFU 0604B-3 3 cores TFU 0805B-2 2 cores Model M Burst Pressure Characteristics Curve and Operating Pressure Max. operating pressure (at 20C) Fluid Tubing I.D. (mm) Tubing O.D.

(coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Impact/Vibration resistance (m/s2) Note 2) 150/30 Dustproof Enclosure Note 1) Based on dynamic performance test JIS B8374-1981 (Standard type: at coil temperature of 20C, with rated voltage, without surge voltage suppressor) Note 2) Impact resistance:

(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) When equipped with DC solenoid/surge voltage suppressor, a delay of about 20 to 30 m/sec. occurs in the OFF response time.

(coil temperature 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction when tested with a drop tester in the axial direction and at a right angle to the main valve and armature, one time each in both energized and deenergized states.

Insulation resistance M/km, 20C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 or more Note) The minimum bending radius of the D-sub connector cables is 20 mm.

Note 2) Safety allowance x3 at 20C Note 3) To calculate flow factor for longer lengths of tube divide factor for 1 metre by actual length in meters.

Flow classification 11 The relation of the average free path of gas molecules and the pipe diameter D expressed as /D is the Knudsen number, and the relation of the pressure p(Torr) converted to air at 20C is expressed as pD.

Approx.1200W(water), 800W(Fluorinert FC-77) Cooling capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Approx.2200W(water), 1500W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 10 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN

Note 2) The above data is based on a room temperature of 20C. Note that you may obtain different figures, depending on temperature conditions. Note 3) The above data shows compatibility guidelines based upon component parts. Therefore, it is no guarantee of product performance.