Vacuum Gripper 60(Operating range 50 to 70)60(Operating range 50 to 70) Pilot valve for supply V114(N.C.) Digital pressure switch ZSE20---M5-A1 Supply valve Circuit diagram -16* Cup distance is changeable. No. TQ1230001-OM105-A 5.2. Center of gravity (ZXP7A-ZPB25JN-X1-ASSISTA) Z Y X X Z (Unit: mm) Center of gravity X Y Z -2.5 -1.63 58.28 Y -17No. TQ1230001-OM105-A 5.3.

If the humidity rises, take measures to prevent the adhesion of water droplets on the valve. 5 VP450-OMH0003-C VPA4*50/4*70/VVPA4*0 Series Precautions for 5 Port Air Operated Valve Be sure to read before handling. Maintenance 1. Perform maintenance and inspection according to the procedures indicated in the operation manual.

(mm) Gripping point L (mm) External grip Series MHKL2 Internal grip Series MHKL2 MHKL2-16D MHKL2-16D 50 50 Gripping force (N) Gripping force (N) 40 40 Pressure 0.6 MPa Pressure 0.6 MPa 30 30 0.5 MPa L L 0.5 MPa 0.4 MPa 0.4 MPa 20 20 0.3 MPa 0.3 MPa 10 10 0.2 MPa 0.2 MPa 0 0 10 20 30 40 50 60 10 20 30 40 50 60 Gripping point L (mm) Gripping point L (mm) MHZ MHKL2-20D MHKL2-20D MHF 80 60 70

min 0.05 l/min 0.5 l/min 1 l/min 0.1 l/pulse 0.05 l/pulse 0.5 l/pulse 1 l/pulse Accumulated pulse flow rate exchange value (Pulse width: 50 ms) Operating fluid temperature Linearity Repeatability Temperature characteristics Note 1) 0 to 50C 3% F.S. or less 5% F.S. or less 3% F.S. or less 2% F.S. or less 5% F.S. or less (0 to 50C, based on 25C) Current consumption (No load) Weight Note 2) 70

Solenoid Operation Direct Piping Manifolds Sub Bass Multiple Sub Bases Ganged Sub Bases Valve Sizing Indications for Flow capacity Orifices in series connection Flow capacity of lubes Valves with Cylinders Auxiliary Valves 70 70 70 71 71 71 72 73 73 73 74 74 75 76 76 78 76 T7 78 79 80 80 81 81 81 82 82 83 84 85 88 APPENDIX Symbols Air Tratment Equipment Actuators Valves Circuits Basic Rules

D STROKE Bore 1.8-10 ISO/VDMA Air Cylinders Series CP95 Dimensions mounting accessories C, D, E and CR [mm] Mounting type C Mounting type D Bore E1 EW TG1FL l1 L I2 d1 CD MR d2 R1 E2 UB CB 32 45 26 32.5 22 5 12 5.5 30 10 9.5 6.6 6.5 48 45 26 40 51 28 38 25 5 15 5.5 35 12 12 6.6 6.5 56 52 28 50 64 32 46.5 27 5 15 6.5 40 12 12 9 8.5 64 60 32 63 74 40 56.5 32 5 20 6.5 45 16 16 9 8.5 75 70

Dimensions/Weight Overall length Reverse mounting Width Symmetric mounting CXS standard CXSJ Height Note) Bore size (mm) Dimensions (mm) Weight (kg) Series Height Width Overall length 0.057 CXSJ6 42 + Stroke 32 13.4 6 CXS6 0.095 58.5 + Stroke 37 16 0.114 CXSJ10 56 + Stroke 42 15 10 CXS10 0.170 72 + Stroke 46 17 Reverse mounting mechanism 0.219 CXSJ15 70 + Stroke 54 19 Reverse mounting 15

Holding MHKL2 series MHKL2-16D MHKL2-16D 50 50 40 40 Holding force N Holding force N Pressure 0.6MPa Pressure 0.6MPa 30 30 0.5MPa 0.5MPa L L 0.4MPa 0.4MPa 0.3MPa 20 20 0.3MPa 10 10 0.2MPa 0.2MPa 0 0 10 20 30 40 50 60 10 20 30 40 50 60 Holding point L mm Holding point L mm MHKL2-20D MHKL2-20D 80 60 70 Pressure 0.6MPa 50 60 Holding force N Holding force N Pressure 0.6MPa 0.5MPa 50 40 0.5MPa

Martensitic stainless steel used for the body and guide block. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 Stroke adjuster 10 Three types available: Rubber stopper, Metal stopper and Shock absorber. 20 Shown with shock absorber 30 40 50 60 70 80 90 Highly flexible piping methods 100 Auto switch capable Two types can be selected, side and axial.

Model Position/No. of solenoid Type Port size {NPTD Cv factor Maxoperating Response time (ms) Weight lbs (kso Plug-in Non Plug-in cycle UPM 2 position Single NVFR4l00 NVFR4110 q6 3.6 300 50 or lesa 1.35 (0.61) \2 Double NVFR4200 NVFR4210 3.6 300 50 or less 1.61 (0.73) ,, 3.7 Closed center NVFR4300 NVFR/I3I O 3.2 180 70 or less 1.61 (0.73) 3.2 Exhaust center NVFF4400 NVFR4410 % 2.8 180 70

C H G F E D B A Port size Model J K 959 317 289 363 157 152 910 260 R 3/4 IDU11C/11D 571 580 30 70 1009 337 309 383 207 175 960 280 R 1 IDU15C : Power source 220 to 240VAC 7

psi 0.25 SCFIVI @ 20 Dsi 0.7 SCFM @ 70 DSi Supply Pressure Variation Effect (Max.)

ZZ 32 40 50 63 80 100 134 138 156 156 184 188 168 176 198 201 240 244 LH LY 4-LD LT (mm) Foot type ZZ + Stroke LS + Stroke X Y X Y LX Bore size (mm) Stroke range X Y LD LH LS LT LX LY LZ ZZ LZ 32 40 50 63 80 100 700 800 1000 1000 1000 1000 9 11 11 14 14 16 22 24 27 27 30 32 7 9 9 12 12 14 30 33 40 45 55 65 128 3.2 3.2 3.2 3.6 4.5 4.5 32 38 46 56 72 89 53 59 50 162 132 55 170 72.5 148 70

22 45 89 41 11 17 36 22.5 23 M5 8 1/4, 3/8 VCL41 111.5 26 26.5 66.5 48 64.5 62 62 50.5 103 64.5 70 30 50 93.5 41 13.5 17 36 25 23 M5 8 1/2 119 26 26.5 70 48 68 62 65.5 50.5 103 68 70 35 60 101 41 17.5 17 36 30 28.2 M5 8 3/4 Note) For class H 4 Direct Operated 2 Port for Oil Series VCL How to Order Manifolds How to Order Manifold Assemblies (Example) VV2C L 2 02 01 Enter the valve and option

kPa 70 kPa 70 Pa 0.50 Pressure loss [kPa] Pressure loss [kPa] Pressure loss [kPa] 0.20 2.0 50 kPa 50 kPa 50 kPa 0.40 0.15 1.5 0.30 0.10 1.0 0.20 100 kPa 100 kPa 100 kPa 300 kPa 0.05 0.5 300 kPa 300 kPa 0.10 0.00 0.0 0.00 0.0 0.1 0.2 0.3 0.4 0.5 0.0 0.6 0.8 0.2 0.4 1.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Flow rate [l/min] Flow rate [l/min] Flow rate [l/min] 954 Flow Sensor Series PFMV5 Dimensions

CXSJ Allowable Static Mass (kg) CXTM CXTL Bore size (mm) CXS (Slide bearing) (Ball bushing bearing) 12 350 60 Caution 16 500 70 20 125 900 1. Make sure that the slide block is stopped at the stroke end. 2. Match the center of the mass to be applied with the center of the slide block.

A specified earth leakage breaker is installed for HRSH090-40/46-. *2: Cable specifications are the examples when using the product at a continuous allowable operating temperature of 70 oC, with an operating voltage of 600 V and two kinds of plastic insulated wires at an ambient temperature of 30 oC. Please select the proper size of cables according to an actual condition.

AF10-A AF20-A 30 27 22 5.4 8.4 40 2.3 28 AF30-A 41 35 23 6.5 13 53 2.3 30 AF40-A 50 52 26 8.5 12.5 70 2.3 35 AF40-06-A 50 52 25 8.5 12.5 70 2.3 34 AF50-A 70 66 35 11 13 90 3.2 47 AF60-A 70 66 35 11 13 90 3.2 47 Dimension:B of auto-drain and optional bowl assembly Optional C D Semistandard 2 6 8 C 6C J 2J 6J 8J CJ 6CJ W 6W 2 6 8 C 6C 2 6 8 AF10-A 59.3 59.9 77.9 77.9 77.9 AF20-A 87.4 87.6

-1 AL-135H AL-136H AL-137H KA00813 (V120) OUT AL-130H-V Hexagon socket head cap screw Relief valve AL-133H-V FKM-70 or EPDM-70 Companion flange Phosphoric ester AL-135H-V e Seal (O-ring) Case AL-136H-V AL-137H-V w O-ring KA00728 (V120) IN Note 1) The material and nominal size notations are based on JISB2401.

Mechanical seal pump Impeller HRLE090-m-20/40 0.5 Usable range 50 Hz Circulating fluid pressure [MPa] 60 Hz 0.4 0.3 Usable range 60 Hz 0.2 50 Hz 0.1 Return port 0 0 10 20 30 40 50 60 70 Circulating fluid flow rate [L/min] * The pump capacity is the capacity of CH1 when 2 L/min are applied to CH2.