(Value in the initial stage) Vibration resistance: No malfunction from test with 8.3 to 2000 Hz 1 sweep, to axis and right angle directions of main valve, each one time when pilot signal ON and OFF .
Clamping Force Specifications W-R1-S2Type Type 1 Type 3 Mass of transferred object 1000 kg or less 3000 kg or less 5000 Possible amount of positional correction 50 mm or less 4000 Clamping force 4430 N 4070 N Clamping force [N] Operating time 1.0 s or more 0.8 s or more 3000 Cylinder operation stroke 83.5 mm 140 mm Bore size 100 mm 2000 Cylinder proof pressure 1 MPa Max. operating pressure
VQC1000/2000 series valves do not come with mounting screws or gaskets. For VQC4000/5000 series valves, when a valve is ordered individually, it comes with a mounting screw but no gasket. VQC1000/2000 series valves do not require separate mounting screws as there are clamp screws built into the manifold.
① Standard strokes from 100 to 1000 mm are available in 100 mm increments, and 1200 to 2000 mm strokes are available in 200 mm increments.
② Intermediate strokes can be manufactured from 1 mm in 1 mm increments for the standard model.
③ Long strokes are available up to the max. available stroke length in 1 mm increments.
Note 1) Be sure to use a mist separator in addition to the filters on the inlet side of IR1000/2000/3000 series regulators.
Note 2) Use a mist separator in addition to the filters on the inlet side of new IR1000-A/2000-A/3000-A series regulators if needed.
This amount should not exceed 4.4 L/min (ANR) for IR1000/2000 series regulators and 11.5 L/min (ANR) for IR3000 series regulators.
For new IR1000-A/2000-A/3000-A series regulators, 1 L/min (ANR) is the max. amount.
Check to confirm whether the leakage is actually bleed air before taking any further steps.
The old IT1000/2000/IT4000 series, however, can be ordered for maintenance purposes (as of May 2021).
Despite this, we recommend replacing any old products with a current ITV1000/2000/3000 series product.
Note) If the input signal of the old IT series product was a 2-wire type current type, only 4 to 20 mADC signal wiring was required, with power supply wiring not required.
Manifold block assembly for series VQC1000/2000 solenoid valves. Multiple options for wiring and port size. Manifold block for series VQC1000/2000 solenoid valves ; Double or single wiring ; Selectable metric and standard port sizes
Serial interface unit EX120 controls up to 16 solenoid outputs and is compatible with series SV1000/2000/3000/4000, VQ1000/2000, SX3000/5000 and SY3000/5000 valves. Available protocols include, but are not limited to DeviceNet™, PROFIBUS-DP®, CC-Link, and AS-i.
Manifold block assembly for series SV1000/2000/3000/4000 solenoid valves. Multiple options for wiring and port size. Manifold block for series SV1000/2000/3000/4000 solenoid valves ; Double or single wiring ; Selectable metric and standard port sizes
Body sizes: 16, 25, 32 ; Maximum speed: 2000 mm/s ; Maximum stroke: 2000 mm ; Positioning repeatability: ±0.1 mm ; Motor types: high load step motor or high speed servo motor
This serial interface is compatible with series SV1000/2000/3000, VQC1000/2000/4000 and S0700 valves. Available protocols include Profibus-DP, DeviceNet™, CC-Link, EtherCat and EtherNet/IP™. Protective structure: IP20; Operating temperature: -10 to 50° C; Operating humidity: 35 to 85%RH (no dew condensation); Acquired standard: CE marking; Weight: 160g
End plate assembly for series VQC1000/2000 valve manifold. Multiple options for exhaust and port size. End plate (U-side) for series VQC1000/2000 valve manifold ; Branch type supply/exhaust available on VQC2000
Replacement cylinder port fittings for Series VQ1000/2000 valve manifolds. For series VQ1000/2000 valve manifolds ; Multiple tubing connection options
Replacement 1(P), 3(R) port fittings for Series VQ1000/2000 valve manifolds. Replacement port fitting ; For series VQ1000/2000 valve manifolds
IP67 enclosure (IP40 for SI unit compatible with ControlNet); Maximum 32 inputs/32 outputs; Connection of sensor with M8/M12 connectors possible; Available communication protocols include: DeviceNet, PROFIBUS DP, CC-Link, AS-i, CANopen and EtherNet/IP; Applicable to valves: VQC1000/2000/4000, S0700 and SV1000/2000/3000
Compatible with series VQ1000/2000 Base Mounted Plug-in Units. For series VQ1000/2000 Base Mounted Plug-in Units ; Prevents cylinder malfunction caused by valve exhaust ; Effective when single action cylinders or exhaust center type solenoid valves are used ; 2 pcs.
Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.
Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.