No.EX-OMP0004CN-I SI (CC-Link ) // EX260-SMJ 2 8 9 10 10 11 LED 16 21 26 26 27 28 -1No.EX-OMP0004CN-I (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating
OFF OFF ON OFF OFF OFF OFF 10 11 OFF OFF ON OFF OFF OFF ON : : : : : : : : HOLD/CLR No.1 Function 62 63 ON ON OFF OFF OFF ON OFF CLR OFF Output is cleared when an error occurs. Output is held when an error occurs.
.404 AR Modular Type Regulators P.412 AL Modular Type Lubricators P.420 AW Modular Type Filter Regulators P.431 ARG Modular Type Regulator with Built-in Pressure Gauge P.437 AWG Modular Type Filter Regulator with Built-in Pressure Gauge P.444 AR425 to 925 Pilot Operated Regulator P.448 AMR3000 to 6000 MR Unit (Regulator with Mist Separator) P.449 ARM5 Compact Manifold Regulator P.453 ARM10/11
11.6 44.8 6.3 19.6 31.7 13.7 13.7 AQ240F-07-07 AQ240F-07-00 13.7 15.4 6.2 40.7 8 10.0 1/4" 1/4" 12 6 12 40.7 6.2 15.1 27.3 13.7 13.7 AQ340F-07-07 AQ340F-07-00 16.8 20.3 7.1 52.2 13 11.8 1/4" 1/4" 13.2 11 13.2 52.2 7.1 20.0 33.1 16.8 13.7 557
Size 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" Symbol Accessory TW 01 03 05 07 09 11 13 Name Nipple Reducer nipple Tube cap Plug U KQ2N KQ2C KQ2P 34
Bracket (Option) 11 $ 40 $ $ 20 $ $ 21 $ None Yes Nil S None Bracket Nil Note 1) 100 and 250 L/min types with flow adjustment valves are not available. Note 2) The flow adjustment valve of this product is not suitable for applications which require constant adjustment of flow rate.
PP depth element Nominal filtration accuracy: 1 to 75m Material: PP EJ202S ... x 11 (L125) EJ302S ... x 11 (L250) EJ402S ... x 11 (L500) b Set the stopper on the retainer while holding down the V-band outside perimeter, and then tighten the wing bolt to the prescribed position.
socket case. (1) Panel mounting hole (Socket side with cover) Panel mounting hole (2) Stretch the cover to install on the cover installation latch. 4-4.5 M4 round head screw 50.5 69.5 SMC 6 1 8 2 3 9 10 46 25 34 11 4 12 5 7 11 43 55 Cover Cover installation latch 38 2
N L1 L2 Weight (g) Port B Min. port size L3 L4 L5 L6 P Q1 Q2 MA MB FA FB KM11-03-09-6 KM11-03-09-10 KM11-07-11-6 KM11-07-11-10 KM11-09-13-6 KM11-09-13-10 6 65 10 40 22 5 32 5 16 18 29.5 19.5 27 10.6 12 16 18.5 6 10 86 6 77.8 10 104 6 85 10 115 61.5 30 48 32 10 19.5 31.5 21.5 30.5 13.2 13 17 21 7 1 4 3 8 73.5 44 52.8 44 12.7 23.7 37.7 25 35.9 15.2 15 18.5 22 9.5 5 16 1 2 83 62 Metric Applicable
QV 11 mm Note 1) Body dimensions when not equipped with auto switches are the same as in the drawings above. Note 2) In the case of single action, a One-touch fitting is on the rod side only. Note 3) These drawings show dimensions when equipped with D-C7, C8 type auto switches. Note 4) These drawings show the piston rod extended.
M1 L M2 D 4 KCH04-00 KCH06-00 KCH08-00 KCH10-00 KCH12-00 42.1 45.8 52.8 59.8 63.5 10.4 12.8 15.2 18.5 20.9 2.6 6.8 16.2 25.6 35.4 18 19 21.5 24 25.5 16 17 18.5 21 22 2.6 6.8 13.1 20.4 30.4 5 8 11 18 24 6 8 10 12 Note) D: max. diameter Straight plug for frequent use: KCH Applicable tube O.D.
The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting options, Standard with adjustable air cushion, Auto switch capable, Cylinder, NCA1, Tie Rod, TIE ROD CYLINDER, 11 lb
Connector Mounting Position: Both Sides 11~20 Stations, Stations: 11 Stations, SUP/EXH Block Mounting: 2~10 Stations: One Side, 11~20 Stations: Both Sides, Port Size: ø6 One-touch Fitting
However, there does not exist stainless steel with absolute corrosion resistance; therefore, many types of stainless steel have been developed for improved corrosion resistance performance. 11 - 6.
Power supply Item Criterion Remedy Measure the voltage at both ends of the DeviceNetTM power supply and check if the voltage is within the specified range. 11 to 25 VDC Investigate the cause of voltage fluctuation and fix the problem.
Compact manifold regulator ARM10/ARM11 ZS-32-D Mounting option Direct precision operated regulator ARP20 (K) /ARP30 (K) /ARP40 (P) 126 A Digital Pressure Switch ISE35 Series Refer to pages 11 and 12 for Pressure Switch Precautions.
Description Material 1 Body ADC 8 Seal NBR 2 Main valve Resin 9 Washer Fe (Chromated) 3 O-ring NBR 10 Compression nut ADC 4 Bonnet ADC 11 Hexagon bolt Stainless steel 5 Sub-valve Resin 6 O-ring NBR 7 Bonnet ADC JSXFAF/Direct Piping Type Port size: Sizes 06, 10 Port size: Size 14 i u y t t r r e e w IN w IN q q Component Parts Component Parts No.
CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.