SMC Corporation of America
Elite Part Number Search
Search Results "11-CDM2XB40-250"

Applicable bore size B2 C2 d H2 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-016C 16 14 16.2 M10 x 1.0 4 Part no. NDd9 NDH10 NX R1 U1 Y-J010C 3.30.030 0.060 3.3+0.048 0 3.2 8 10 NTJ-015C 16 8 9.2 M5 x 0.8 4 Y-J016C 50.030 0.060 5+0.048 0 6.5 12 10 * A knuckle pin and retaining rings are included.

Refer to the above drawing for other dimensions. n L 1 38 28 2 57 47 3 76 66 4 95 85 5 114 104 6 133 123 7 152 142 8 171 161 9 190 180 10 209 199 11 228 218 12 247 237 13 266 256 14 285 275 15 304 294 16 323 313 17 342 332 18 361 351 19 380 370 20 399 389 L1 L2 1417 A VK300 Series Specific Product Precautions Be sure to read this before handling the products.

ZP3P-35PTSF ZP3P-50PTSF 11 ZP3P Series Buffer Assembly Part Nos.

ZX B B A B A B ZR P1 A A ZM 10 9 4 5 ZMA ZQ 3 ZH ZU ZL ZY ZF 11 ZP Section A-A' (Ejector) 12 SP 2 7 ZCUK AMJ 8 AMV AEP HEP Related Equipment 6 1 Section B-B' (Solenoid valve) Component Parts Replacement Parts Description Material Note Description Part no. No. No.

Refer to page 14-20-11 for flow characteristics and the graph below for max. air flow. AFF HA Model Selection Max. Air Flow Max. flow line AT Select the model in accordance with the following procedure taking the inlet pressure and max. air flow into consideration. (Example) Inlet pressure: 0.6 MPa Max. air flow capacity: 5 m3/min (ANR) 1.

D-X 20Data 10-9-11 11 Lever Detection Switch (Proximity Switch) Proximity Switch Specifications/Maker: OMRON Corp. Mounting Position E2E-X1C1 E2E-X2D1-N Model RSH20, 32 RS1H50, 63, 80 Applicable cylinder bore size E2E-X1C1 (For RSH20/32) While holding the lever in the detection range of the switch, screw in the switch gradually until the indicator light (red) turns on.

The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers

The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, CLEAN ROOM, ACTUATOR, ELECTRIC ACTUATOR, G5, 16MM LE ELECTRIC ACTUATOR, 4.35779 lb

The LEF series slider type electric actuator features a low profile height of 46mm *. The actuators main body can be mounted without removing any exterior components, such as the cover, making installation easy. The standard equipped seal band covers the guide, ball screw and belt, preventing grease and external foreign matter from splashing and entering the LEF. There are 2 types of drivers

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, CLEAN ROOM, ACTUATOR, ELECTRIC ACTUATOR, I5, 25MM LE ELECTRIC ACTUATOR, 11.64775 lb

Content 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.

No.EX-OMV0023-A PRODUCT NAME SI unit for Ethernet POWERLINK MODEL / Series / Product Number EX260 Series Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 10 Installation 10 Wiring 11 LED Indication and Settings 15 Configuration 17 Troubleshooting and Maintenance 21 Specifications 26 Specifications 26 Dimensions

Report fault by diagnostics, show on diagnostic LED, and inhibit turn on. 11 Reverse supply protection External installation error Polarity diode No function and no supply to valves. In addition: The device goes into the Fail-safe state if it detects a fault. In Fail-safe state the output is "Off".

There are differences in the displayed values when using more than Refer to Trouble No.11 one product. The display accuracy Refer to Trouble No.12 does not meet the specifications. Applied voltage does Refer to Trouble No.8 not match with the displayed pressure value. The Display Refer to Trouble No.13 measurement unit cannot be changed. Buttons do not work.

There are differences in the displayed values when using more than Refer to Trouble No.11 one product. The display accuracy Refer to Trouble No.12 does not meet the specifications. Applied voltage does Refer to Trouble No.8 not match with the displayed pressure value. The Display Refer to Trouble No.13 measurement unit cannot be changed. Buttons do not work.

No.TQ0010298-OM003-A PRODUCT NAME Digital pressure switch for energy-saving control ejector MODEL / Series / Product Number ZME-ZSE***-A Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Installation 14 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17

Units display (Accumulated flow) Indicates the flow measurement units currently selected. 11 No.PF-OMU0002-D Definition and terminology Term Definition A The total amount of fluid that has passed through the device. If an instantaneous flow of 100 L/min lasts for 5 minutes, the accumulated flow will be 5 x 100 = 500 L.

No.10 There are differences Refer to Trouble in the displayed values when using more than one No.11 pressure switch. The display accuracy Refer to Trouble does not meet the No.12 specifications. Applied voltage does Refer to Trouble not match with the No.8 displayed flow value. The Display Refer to Trouble measurement unit No.13 cannot be changed. Buttons do not work.