NO OFF n-2 n-1 Real-time flow rate Flow rate conversion Normal condition: 0C, 101.3 kPa, dry air Standard condition: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these conditions.
Piston rod Table (2) MXP6 MXP10/12/16 L2 L2 L2 (mm) 10 (One side only) 10 (One side only) 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Damage is not allowed. 3. Shock absorber is considered a consumable component. When energy absorption is decreased, replace it.
Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C (4F)) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa (psi) 0.3 to 0.85 (43 to 123) 0.3 to 1.0 (43 to 145) Inlet air temperature C (F) Note
MXP6 MXP8, 10, 12, 16 L2 L2 Shock absorber model RB0805 RB0805 RB0806 Applicable size MXP10 MXP12 MXP16 L2 Table 2 L2 (mm) 10 (one side only) 10 (one side only) 9 8 9 8 8 8 8 8 Model MXP6-5C MXP6-10C MXP8-10C MXP8-20C MXP10-10C MXP10-20C MXP12-15C MXP12-25C MXP16-20C MXP16-30C Stroke Adjustment Urethane bumper Lock nut Lock nut MXP6 MXP8, 10, 12, 16 Shock Absorber Loosen the lock nut, adjust
Bracket model no. 300 1,000 3,000 6,000 10,000 Exhaust of oil mist 3 8 3 4 1 2 1.7 1 2 1 A Drain cock (Standard) 0.2 AMC-EL3 BE30 0.5 AMC-EL5 BE50 0.7 AMC-EL6 BE60 1.2 AMC-EL8 D Drain piping AMC-EL9 Thread type Applicable to drain piping ANR: 20C atmospheric pressure, relative humidity 65% Nil N F Rc NPT G Model/Female Thread Type Model Specifications Effective area (mm2) AMC220 AMC320
ON: 5 or less, OFF: 4 or less Response time (DC) ms Note 1) 20 Max. operating frequency (Hz) Manual override Non-locking push type, push-turn locking slotted type Not required Lubrication Unrestricted Mounting position 150/30 Impact / vibration resistance (m/s2) Note 2) Dust tight Enclosure Note 1) Based on dynamic performance test, JIS B 8374-1981 (Standard type :Coil temperature 20C, at
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
, 4 6, 8, 10 8,10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8" 5/32" 1/8", 3/16" 1/8" 5/32" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 3/8" 1/4" 1/4", 5/32" Controlled flow (Free flow) Flow rate /min (ANR) 20 100 180 230 260 390 460 660 790 920 1580 1710 0.3 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Effective area (mm 2) Note 1) Flow rate values are measured at 0.5 MPa and 20C
Metric sizes 6 8 10 12 Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 (free) flow Effective area mm 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
drain Float type (Normally closed) Float type (Normally open) Refrigerant R407C (HFC) IDF D Port size Rc3/8 Rc1/2 Rc3/4 Rc1 Weight [kg] 16 17 18 22 23 27 28 46 Coating color Body panel: White 1 Base: Gray 2 Applicable air compressor output [kW] (Reference) For screw type 0.75 1.5 2.2 3.7 5.5 7.5 11 15 Refrigerant R134a (HFC) IDU E *1 Air flow capacity under the standard condition (ANR) [20C
0.7 MPa Pressure 0.7 MPa 50 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 400 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 0.6 MPa 0.6 MPa 0.6 MPa 0.5 MPa 0.5 MPa 40 300 0.5 MPa 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 0.4 MPa 0.4 MPa 0.3 MPa 0.3 MPa 200 20 0.3 MPa 0.3 MPa 0.25 MPa 0.25 MPa 100 10 0 10 20 30 40 50 60 0 20 40 60 80 100 120 Gripping point L (mm) Gripping point L (mm) MHZ2-20C
Note 4) Indicates the bending value when the outside diameter rate of change is 10% or less at a temperature of 20C.
Solenoid Coil Specifications DC Specification Temperature rise (C) Note) Model Power consumption (W) 45 45 60 VX31 VX32 VX33 4.5 7 10.5 Note) The values are for an ambient temperature of 20C and at the rated voltage.
servo motor (100/200 VAC) Encoder Incremental 17-bit encoder (Resolution: 131072 p/rev) Horizontal 45 65 Power consumption [W] *5 Vertical 145 175 Horizontal 2 Standby power consumption when operating [W] *6 Vertical 8 Max. instantaneous power consumption [W] *7 445 724 Type *8 Non-magnetizing lock specifications Lock unit Holding force[N] 131 255 157 308 197 385 Power consumption [W] at 20C
ANR: 20C at atmospheric pressure, relative humidity 65% 1 mg/m 3 (ANR) 0.8 ppmW/W Note 2) If there is a special law under operation, the law has ultimate priority. Note 3) It describes the grade of compressed air quality based on ISO8573-1: 1991 and JIS B 8392-1: 2000. (Refer to table on top in following page.)
Series DXT474 Environment How to Calculate Flow Rate (At an air temperature 20C) Subsonic flow : P1+0.1013<1.89(P2+0.1013) 1 Do not use in atmospheres where the valve is in direct contact with corrosive gases, chemicals, salt water, water or steam. 2 Do not use in an explosive atmosphere. 3 Do not use in a place subjected to heavy vibration and/or shock.
25%, 70C) Inorganic salt 3 Boric acid 4 Sulfuric acid (30%, Room temperature) 5 Phosphoric acid (50%, Room temperature) 6 Ammonium hydroxide (28%) 7 Sodium hydroxide (30%, Room temperature) Inorganic alkali 8 Calcium hydroxide 9 Magnesium hydroxide 10 Acetylene 11 Formic acid (25%, Room temperature) Organic solvent 12 Citric acid 13 Acetic acid (10%, Room temperature) 14 Lactic acid (5%, 20C
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
16" 3/8" 3/16", 1/4" l/min (ANR) (CFM) 7 (0.25) 12 (0.42) 38 (1.33) Flow rate Controlled flow 0.1 (0.006) 0.6 (0.03) 0.2 (0.01) Effective area mm (cv) Free flow l/min (ANR) (CFM) Flow rate 175 (6.1) 350 (12.3) 75 (2.6) 295 (10.3) 5.3 (5.3) 2.7 (0.15) 1.1 (0.06) Effective area mm (cv) 4.5 (0.25) Note 1) Flow rates are the values measured with pressure at 0.5MPa (72psi) and temperature at 20C