Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewied Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 550, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 750, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: With Magnet, Mounting: Basic, Bore Size: 50mm, Port Thread Type: NPT, Stroke: 50mm, Rod End Nut: Without Rod End Nut, Cushion: With Cushion in Both Sides, Port Position: Port on Top - Cushion Valve Down, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: -
Bore Size: Ø100, Thread: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 20mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 6mm, Suffix: Required Selection w/Speed Control
Bore Size: Ø32, Thread: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 40mm, Auto Switch: Z73--Reed, DC Volt., AC Volt, 2 Wire, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 6mm, Suffix: Required Selection w/Speed Control
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of the table top. T-slots are provided on 3 faces of the MGF body *, allowing mounting of various brackets. Optional auto switches can be mounted
The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap
The MB series is available with many standard options, which include stroke adjustment, tandem, high/low temperature seals, heavy rod scraper, non-rotating rod, double rod and many more.Standard: double acting single rod , Bore sizes: 32, 40, 50, 63, 80, 100, 125 * , Strokes from 25mm through 1500mm depending upon bore size , Mounts: basic, foot, front and rear flange, single or double clevis
Compact guide cylinder, slide bushing, new style , Bore size: 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 (mm) , Strokes: 10mm through 400mm, depending upon bore size , Variety of switches with a variety of lead wire lengths, "MGP, MGP, GUIDED CYLINDER, N lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com