Make sure the trunnions do not move by hand. Slide the trunnion to the specified location. * Keep a gap between the cylinder tube and retaining bracket so that they do not contact each other (4 places).
Also, do not use the cylinder with fixed at external slider to avoid excessive moment applied to bearing of the cylinder. And, if the cylinder is mounted with axial compressing force applied, the cylinder tube is deflected and operating failure may be caused.
Polyurethane TU0425 2.5mm 4mm Metric size q Do not forcibly connect piping that could apply a lateral force to the cylinder tube, as this could cause the cylinder tube to tilt and lead to a malfunction.
Do not supply air pressure from ports other than 1(P) port. The valve will malfunction when air pressure is supplied from other ports. 3. Do not use the valve under negative pressure. Component Parts No. Zinc die-casted Aluminium die-casted Material Note q Description Valve guide Body Chromated Chromated Chromated Selection w e Handle r Brass Valve Zinc alloy Caution 1.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com T VMG Note) Do not use it to cut the metalic materials such as electric wires. Note) Do not use it to cut the metalic materials such as electric wires.
Do not use for other purposes. Solenoid valve combination symbol Combination no.
(lf lubrication is used, do not discontinue its us.) Olf the kinetic energy oI the load exceeds the permissible range, use external stops to absorb load. O Connect piping atter thoroughly flushing it. O Do not use trydraulic fluid. @Shaft Load lf a static (i.e. non-dynamic) load only is applied to the actuatot it is possible io apply the load values shown in the table below.
Note 2) Do not release the OUT side piping port of the product directly to the atmosphere without connecting piping. If the product is used with the piping port released to atmosphere, accuracy may vary.
Do not use this aftercooler in an area that has viscous dust (electrostatic paint powder, oily particles, etc.). If it must be used under such conditions due to unavoidable circumstances, please contact SMC beforehand.
Option Port size (P, A, B port) Thread type Nil F G Rc Nil Z None Nil 01 Without sub-plate 1 8 1 4 With light/surge voltage suppressor 02 N NPT Piping (P, A, B, EA, EB port) T NPTF EA, EB port: Rc 1/8 Nil B Side ported Bottom ported Option SJ 1 00 01 F Plug-in VFR2 5 SY 1 E 10 1 Non plug-in VFR2 02 SV CE-compliant SYJ Q CE-compliant Nil Pilot valve manual override SZ Electrical entry: D/DO
Note 1) Do not use the product in an atmosphere and place where there is direct contact with chemicals. It may cause damage to the body. (Alcohol, acetone, etc. also cause damage, so be sure for the product not to be close to them.) Note 2) Do not use it in a line that is kept pressurized because it could cause the body to break.
Caution Do not uninstall, with the power supply connected to the controller.
Caution Do not uninstall, with the power supply connected to the controller. The driver will not be uninstalled correctly. -6No.SFOD-OMT0008 Revision history No.
Do not install, copy or use this Software if the terms of this Agreement cannot be accepted. The terms of this Agreement must be accepted by the user before downloading this Software if this Software has been supplied by SMC via the Internet or any other means. Do not download this Software if you cannot accept the terms of this Agreement. Article 1 (Grant of license) 1.
Do not install, copy or use this Software if the terms of this Agreement cannot be accepted. The terms of this Agreement must be accepted by the user before downloading this Software if this Software has been supplied by SMC via the Internet or any other means. Do not download this Software if you cannot accept the terms of this Agreement. Article 1 (Grant of license) 1.
Do not install, copy or use this Software if the terms of this Agreement cannot be accepted. The terms of this Agreement must be accepted by the user before downloading this Software if this Software has been supplied by SMC via the Internet or any other means. Do not download this Software if you cannot accept the terms of this Agreement. Article 1 (Grant of license) 1.
Do not forget to conduct drain piping at the outlet of the drain valve. It is recommended to use an automatic drain system for savings in labor. We recommend our auto drain in the table below.
Do the drain pulling out regularly.
(lf lubrication is used, do not discontinue its us.) Olf the kinetic energy oI the load exceeds the permissible range, use external stops to absorb load. O Connect piping atter thoroughly flushing it. O Do not use trydraulic fluid. @Shaft Load lf a static (i.e. non-dynamic) load only is applied to the actuatot it is possible io apply the load values shown in the table below.
Do not hold the terminal block box or the switch. ISE70 ZSE80 ISE80 Lead wire with connector ZSE ISE Knurl ZSP PS 3. Connect the colored wires coming from the cable terminal. Refer to the circuit diagram and table above to avoid mistakes.