Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. Air Supply 1. Type of fluids Please consult with SMC when using the product in applications other than compressed air. 3. Do not use in a place subject to heavy vibration and/or shock. Warning 4.

Do not use the compression fitting of the valve to support the piping. The piping could disconnect from the valve. Be sure to mount the valve to secured piping. (Compression fittings do not have a valve-holding function.) Caution 1. Use a steel tube for the IN and OUT piping. 2.

Operating Environment Maintenance Caution Warning 1.Do not use in atmospheres where the valve is in direct contact with corrosive gases, chemicals, salt water, water or steam. 2.Do not use in locations subject to vibration or impact.

Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 6.

Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water vapor, or where there is direct contact with any of these. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.

Do not use until you can verify that equipment can operate properly. Verify correct mounting by suitable function and leakage inspections after air and power are connected following mounting, maintenance or conversions. 2. Do not drop or bump. Do not drop, bump or apply excessive impact (1000 m/s2) when handling.

Do not use with flammable or highly permeable fluids. Fire, explosion, damage or corrosion can result.

Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. 1 L+ Brown 18 to 30 VDC 2 N.C.

Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. UP button Selects a mode and the display shown at the sub screen, and increases the ON/OFF set values.

Do not apply fluid under leaking conditions. Safety cannot be assured in the case of unexpected malfunction.

Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. 5% of rated flow Hysteresis Setting of hysteresis can prevent chattering. UP button Selects a mode and the display shown at the sub screen, and increases the ON/OFF set values.

When circulating coagulable fluids, handle them carefully so that they do not coagulate in the pump.

Do not use with corrosive fluid. Do not use fluid which swell or deteriorates packing, O ring or element. 1. Pressure drop (P) Set the flow so that the initial pressure drop is 0.02 MPa or less. 2. Space to install Reserve maintenance space for installation and piping. 4. Operating environment Do not use in corrosive environment. Do not use where exposed to vibration or impact.

Pressure drop (P) Operating temperature Do not use where temperature exceeding specified range. Set the flow so that the initial pressure drop is 0.02MPa or less. Operating fluid Do not use this for gases. Do not use with corrosive fluid. Do not use fluid which swell or deteriorates packing, O ring or element. Space to install Reserve maintenance space for installation and piping.

Operating environment Warning 1) Do not use in environments where there is a danger of corrosion.

Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these . 2. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 3. Do not use in a place subject to heavy vibration and/or shock. 4.

Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. 3. Do not use in a place subject to heavy vibration and/or shock. 4.

Do not allow a pallet to collide with the cylinder when the lever is upright. In case of a lever with built-in shock absorber type, do not collide the next pallet against the first one while the lever is standing erect. Otherwise, all energy will be applied to the cylinder body.

Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these . 2. Do not use in an environment where flammable gas or explosive gas exists. The products do not have an explosion proof construction. 3. Do not use in a place subject to heavy vibration and/or shock. 4.

Do not use an open tank. Ensure that the INLET and OUTLET for circulating fluid is connected correctly. If any valves are used ensure that they do not restrict the flow, otherwise low flow my cause an alarm. 3.5 Handling Transport Thermo-con with both handles.