Refrigerant Air connection 300 2.2 IDU3D 350 Series IDU High inlet air temperature type Rated temperature of 50 to 60C Rc 3/8 60C 430 3.7 IDU4D 500 Small Medium Small Medium Large R134a 1 to 4 R 1/2 640 5.5 IDU6D 750 55C R 3/4 Air cooled Air cooled 850 7.5 IDU8D 1000 IDU11D R134a 1300 11 R 3/4 1500 IDU11C 1300 55C 2400 IDU15C 15 2050 R 1 3700 IDU22C/22C1 22 3150 R22 5 to 8 6100 IDU37C/37C1
T dimension) 0 1 5 None Differential pressure indicator Differential pressure indication switch Note) 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) 30 FH FH Note) N.C. and N.O. common Note) When the differential pressure indication 1 or 5 is selected, the connection method is 2 to 5. (0 and 1 cannot be selected.)
Applicable Stroke Table : Standard Model Stroke [mm] 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 Manufacturable stroke range [mm] LEFS16 50 to 500 LEFS25 50 to 600 LEFS32 50 to 800 LEFS40 150 to 1000 * Please consult with SMC for non-standard strokes as they are produced as special orders. The actuator and controller/driver are sold as a package.
acting, Single rod Action Air Fluid 1 MPa Proof pressure 10.7 MPa Maximum operating pressure 0.12 MPa 0.06 MPa Rubber bumper Minimum operating pressure CJ1 0.1 MPa Air cushion Without auto switch: 10C to 70C, With auto switch: 10C to 60C Ambient and fluid temperature CJP Rubber bumper/Air cushion Cushion Not required (Non-lube) Lubrication CJ2 +1.0 0 Stroke length tolerance CM2 50 to 750
Specifications Model MGC20 MGC25 MGC32 MGC40 MGC50 Base cylinder CDG1BA Auto switch Bore size Port thread type Stroke 20 25 32 40 50 Bore size (mm) Action Double acting Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.15 MPa (Horizontal with no load) 10 to 60C Ambient and fluid temperature Piston speed 50 to 750 mm/s Cushion Air cushion MGJ
bumper (Magnet type) Standard Strokes Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 50, 100, 150, 200 Made to Order Made to Order: Individual Specifications (For details, refer to pages 1507 and 1508.) 300 6 50, 100, 150, 200, 250, 300 500 Symbol Specifications 10 -X116 -X168 -X210 -X322 -X324 -X431 -X2423 Air-hydro 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750
The maximum speed of 750 mm/s can be accommodated if the piston is to be locked in the stationary state for the purpose of drop prevention. CLQ Made to Order Specifications (For details, refer to page 9-16-1.)
[UL-compliant products] When conformity to UL is required, the electric actuator and controller/driver should be used with a UL1310 Class 2 power supply. 50 50 to to 1000 1000 * Refer to the applicable stroke table. y Motor option Nil Without option B With lock Applicable Stroke Table V: Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950
Type Double acting, Single rod Action Air Fluid 145 psi (1.0 MPa) Proof pressure 102 psi (0.7 MPa) Maximum operating pressure 7 psi (0.05 MPa) Minimum operating pressure Without auto switch: 14 to 158F (10 to 70C) (No freezing) With auto switch: 14 to 140F (10 to 60C) (No freezing) Ambient and fluid temperature Not required (Non-lube) Lubrication +1.4 0 mm Stroke length tolerance 50 to 750
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com T 600 VMG 400 750 With rollers convenient for moving With slant prevention structure adjustable with numbers of reels set Tube Reel: TBR-1/2/3/4 Tube Stand: TB-2 Applicable tubing size (mm) Model 4, 6 TBR-1 8 TBR-2 10 TBR-3 12 TBR-4 15-6-35
750 240 100 IDG100M2 IDG100HM2 IDG100LAM3 IDG100SAM3 1000 1000 300 150 Rated conditions are 0.7 MPa of inlet air pressure and 25oC of inlet air temperature.
IDG75HV IDG100HV 25 50 100 200 300 500 600 750 1000 25 50 100 200 300 500 600 750 1000 IDG30LV IDG50LV IDG60LV IDG75LV IDG100LV 75 110 170 240 300 IDG60SV IDG75SV IDG100SV 50 100 150 Note) Standard dew point : Outlet air atmospheric pressure dew point under standard performance conditions Standard purge rate : Ratio of purge air flow rate to inlet air flow rate under standard performance
combined with the single style 25 (0.88) 50 (1.77) 100 (3.53) 200 (7.06) 300 (10.59) 500 (17.66) 600 (21.19) 750 (26.49) 1000 (35.31) IDG3M IDG5M IDG10M IDG20M IDG30M IDG50M IDG60M IDG75M IDG100M 25 (0.88) 50 (1.77) 100 (3.53) 200 (7.06) 300 (10.59) 500 (17.66) 600 (21.19) 750 (26.49) 1000 (35.31) IDG3HM IDG5HM IDG10HM IDG20HM IDG30HM IDG50HM IDG60HM IDG75HM IDG100HM 75 (2.65) 110 (3.88)
Condition: Pressure 0.5MPa, Load 50%, Piping length 5m Effective area mm 2(Cv ) Cylinder speed (mm/s) 50 63 80 100 125 140 Bore size (mm) 160 180 200 250 300 Port size Rc(PT) 40 250 25(1.4) VEX312 -01, 02 500 750 02 ( 1 4) 60(3.3) 250 500 750 250 500 750 500 750 1000 500 750 1000 250 500 750 250 500 750 VEX332 -02, 03, 04 Body ported Base mounted 03 (3 8) 160(8.9) VEX350 -04, 06, 10 06 (3
PFA711, 721, 751 PFA711, 721, 751 NPN open collector 2 outputs 27 1/8 1/4 3/8 1/2 01 02 03 04 PFA710, 750 NPN open collector 1 output + Analog output (1 to 5V) 28 PFA711, 721 PFA751 PFA710, 750 PFA711, 721, 751 PFA711, 721, 751 PNP open collector 2 outputs 67 PNP open collector 1 output + Analog output (1 to 5V) 68 Specifications PFA710 PFA750 PFA711 PFA721 PFA751 Model Measured fluid
Refer to pages starting with 181 for mounting. 3-8H10 depth 10 30 A B Stroke Model LG1H202PC-500-F LG1H202PC-600-F LG1H202PC-700-F LG1H202PC-800-F LG1H202PC-900-F LG1H202PC-1000-F 350 450 550 650 750 850 370 470 570 670 770 870 500 600 700 800 900 1000 95 B 100 95 8-6.2 110 95 20 95 A Positioning Time Guide Positioning time Positioning time (sec.)
Page 750 Serial Transmission S Kit . Page 753 Options . Page 755 Construction . Page 758 Replacement Parts . Page 760 Specific Product Precautions .
to 620 8 to 310 30 to 750 20 to 550 10 to 300 Parallel Stroke range 701 to 800 20 to 550 12 to 330 6 to 180 24 to 750 16 to 500 8 to 250 30 to 750 20 to 550 10 to 300 801 to 900 24 to 610 16 to 410 8 to 200 30 to 750 20 to 550 10 to 300 901 to 1000 24 to 500 16 to 340 8 to 170 30 to 750 20 to 520 10 to 250 1001 to 1100 30 to 660 20 to 440 10 to 220 1101 to 1200 30 to 570 20 to 380 10 to
CM2 Air Cylinder: Standard Type Double Acting, Single Rod Specifications 20 25 32 40 Bore size (mm) Type Pneumatic Action Double acting, Single rod Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.05 MPa CJ1 Ambient and fluid temperature Not required (Non-lube) Lubrication CJP Stroke length tolerance Clevis integrated Rubber bumper: 50 to 750
auto switch model, refer to Best Pneumatics Stroke Hundredths of an inch (i.e. 06 = 0.06") Standard stroke Inches Specifications Specifications 075 (3/4") 200 (2") 106 (1 1/16") 150 (1 1/2") Bore size (in) Fluid Air Maximum operating pressure 250 PSI/1.7 MPa Minimum operating pressure 8 PSI/0.06 MPa Ambient and fluid temperature 40 to 140F / 5 to 60 C Piston speed 2 to 30 in/sec (50 to 750