Set Pressure: 0 (0.005MPa~0.2MPa), Port Size: M5 (M5X0.8), Gauge Port Direction: R (Right)
Rated Pressure Range: -14.50 to 14.50 psi, Piping: M5 x 0.8, Female Thread, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -
Rated Pressure Range: 0.00 to -14.69 psi, Piping: M5 x 0.8, Female Thread, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -
Size: M5, Reverse Flow: Regulator, Standard, Thread: M Thread, Rc(PT), Port Size: M5, Accessory: None, Option 1: None, Option 2: Flow Direction: Right->Left
Piping: M5 x 0.8, Female Thread, Output Specification: NPN Open Collector 2 Outputs+Analog Voltage/Auto-shift Switching, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
S S S S F0 function setting F1 function setting F99 function setting [Measurement mode] Measurement mode is the condition where the flow is detected and displayed, and the switch function is operating. This is the basic mode; other modes should be selected for set-point changes and other function settings. Do not use the product for flammable fluid. Fire or explosion can result.
Air flow direction: Port P Port A , Port R Block Component Parts Operation principle
x 0.8 Thread depth 7.5 Auto switch mounting groove on workpiece release side 4 x M5 x 0.8 Thread depth 7.5 4 x M5 x 0.8 Thread depth 7.5 Rc1/8 4 x 29 Auto switch insert area 15 15 15 17 (Workpiece adsorption port) 6.4 6.4 58 6.4 74.2 A (Refer to the figure below.) 6.8 66 58 58 Auto switch mounting groove on workpiece adsorption side Rc1/8 (Workpiece release port) Bumper (9.8) (26.5) (25.1
While the part number “AS1201F-M5-06A” is indeed viable, “AS1201F-M5-06SA” is not. The “S” is for sealant on the tapered male pipe threads. As the port size of the AS1201F is M5, which is a parallel thread (metric coarse thread), there is no sealant because it uses a gasket seal.
Stations: 5 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 6 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 2 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 1 Station, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 4 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 3 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 12 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]
Stations: 10 Stations, Pressure Sensor/Vacuum Pressure Switch Mountable: S (Sensor/Switch Mountable Base), Common Supply, PV Port Size: M5 (M5x0.8), Common Release Pressure, PD Port Size: M5 [M5 x 0.8 (PV≠PD)]