Pad Shape: [Other Shape] Flat Type, Pad Type: Standard, Mounting Method: Recessed, Material: Rubber Group, Rubber Group Material: Urethane Rubber, Environment: Standard, Vacuum Outlet Port: Barbed Couplers, Pad diameter(ø): 13, Vacuum entry port thread diameter: ø4 urethane tube, Mounting connection screw: M5 × 0.8 (male thread)

Valve Mounting Direction: S (Solenoid on Same Side as A Port), Piping: 42 (Base Mounted), Stations: 13 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)

Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: 42 (Base Mounted), Stations: 13 Stations, A Port Size: M5 (Base Mounted M5X0.8)

Valve Mounting Direction: Solenoid on Side Opposite to A Port, Piping: 42 (Base Mounted), Stations: 13 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)

Valve Mounting Direction: Solenoid on the Side Opposite to A Port, Piping: 42R (Base Mounted), Stations: 13 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)

Valve Mounting Direction: S (Solenoid on Same Side as A Port), Piping: 42R (Base Mounted), Stations: 13 Stations, A Port Size: M5 (Base Mounted M5X0.8), P R Port Thread: T (NPTF)

Size: 20 (Exhaust: Circumference, Noise Reduction: 13/18 dB,Effective Area 1/5 mm²), Port Size: M5

ISE20B-L incorporates IO-Link 16-bit process data includes 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure valve.   The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange.  ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

ZSE20B(F)-L incorporates IO-Link 16-bit process data includes 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure value.  The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange.  ZSE20B(F)-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

ZSE20B(F)-L incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit and 13 bits for the measured value.  The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange. 

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket mounting options

ZSE20B(F)-L-S incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure value. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange.

ZSE20B(F)-L-S incorporates IO-Link version 1.1 and COM2 speed. 16-bit process data include 2 output bits for set points, a diagnosis bit, and 13 bits for the measured pressure value. The 3-screen, 3-color display shows the instantaneous reading in red or green, and the setting label and its numerical value in orange.

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: Standard, Attachment: Standard, Semi-Standard 1: 13 ( 1 + 3), Semi-Standard 2: N (Non-Relieving Exhaust Mechanism)

Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 13 ( 1 + 3), Semi-Standard 2: N (Non-Relieving Exhaust Mechanism)