Note 2) Refer to the specifications of display unit for the flow rate value per pulse. 340 Clean Air Module LLB Series Dimensions LLB3-1-PRVSF V2 49.5 HAA HAW Mounting hole for 4 x M4 AT 45 37 35 IDF IDU 1.5 4 20.5 278.5 50 IDF FS A Valve open and locked position Rc 1/4 (NPT 1/4) Rc 1/4 (NPT 1/4) IDFA 90 (Lever operating direction) Max. 91 IDFB A Hand valve Valve closed position 5.5 39 IDH

INP 1 INP ON 0.50 2 INP ON a bINP ON < / [mm/sec] [mm/sec] 1 4 30% 1 4 40% 5 20 35% 5 20 60% LEY*16** 21 50 60% 85% LEY*16*A* 21 50 80% 95% 1 4 20% 1 4 40% 5 20 35% 5 20 60% LEY*25** 21 35 50% 65% LEY*25*A* 21 35 80% 95% 1 4 20% 5 20 35% LEY*32** 21 30 60% 85% -41- LEY*16** LEY*25** LEY*32** LEY*16*A* LEY*25*A* A B C A B C A B C A B C A B C [kg] 1 1.5

Material Part list/LVM11 Body 1 PEEK Diaphragm assembly 2 EPDM/FKM/Kalrez t Spacer 3 PBT Armature assembly 4 Stainless steel/POM r Coil assembly 5 u y Sleeve 6 Iron Return spring 7 Stainless steel w e Board assembly 8 q !1 Casing 9 PBT Plug 10 NBR O-ring 11 NBR LVM11R LVM12R !2 !2 !0 !0 !1 !1 y y t t u u i i o o !3 !3 r r w w e e q q LVM112 !2 !0 Description No.

Width across flats 13 Operating port Rc 1/8 (NPT 1/8, G 1/8) 8 x M5 x 0.8 thread depth 13 Note) A Operating direction 6H9 + 0.030 0 depth 5.5 (Insert) 7 (Hexagon socket head taper thread plug) 48 98 72 41 10 8 25 40 40 40 Y Y Operating port Rc 1/8 (NPT 1/8, G 1/8) 41 160 B Operating direction 6H9 + 0.030 0 depth 5.5 (Hexagon socket head taper thread plug) 10.5 Operating direction B A 9.5

2 Carbon steel 9 Steel ball 1 Magnetic material 10 Magnet A F D9 type (2) 11 Auto switch 1 NBR 12 Piston gasket 2 NBR 13 Piston seal 1 NBR 14 Rod seal 1 NBR 15 Gasket 3 Free-Mounting Cylinder with Air Cushion Series CU Dimensions 2-cushion needle 2-port 2-P through Q R E GB GA 4-NN MM D CB CA C K J JA E H A' A 2-P through KA B 4-T counterbore Width across flats L S + Stroke Z + Stroke (mm

1 !3 @2 q $4 #3 #1 #0 @1 $2 !7 @5 #8 #6 #4 @6 @7 @8 @4 Auto switch $1 #5 #9 #8 #2 @3 !9 $0 $2 !1 !8 !6 #7 !0 @9 A @0 !5 A !

Material Part list/LVM11 Body 1 PEEK Diaphragm assembly 2 EPDM/FKM/Kalrez t Spacer 3 PBT Armature assembly 4 Stainless steel/POM r Coil assembly 5 u y Sleeve 6 Iron Return spring 7 Stainless steel w e Board assembly 8 q !1 Casing 9 PBT Plug 10 NBR O-ring 11 NBR LVM11R LVM12R !2 !2 !0 !0 !1 !1 y y t t u u i i o o !3 !3 r r w w e e q q LVM112 !2 !0 Description No.

(0.68 kg) 3) Option (Part number: AP PL 210) 4) 1.5 lbs (0.68 kg) 3) N/A 1) High temperature available.

Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as follows. 4.

1 2 4 3 2 1 110 VAC 50/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Symbol A: Non-locking push type A (projecting) N.C. 0.5 MPa N.O. 1 MPa N.C. 1 MPa 4 1 6A 8A 10A 10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz 7 Valve size 1 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC

Contents q Cover L (1 pc.) w Cover R (1 pc.) e Top covers (2 pcs.) r Hexagon head bolts (4 pcs.) t Flat washers (4 pcs.) y Cover mounting bolts (8 pcs.)

Description Number Note 1 Body 1 Anodized 2 Cover 2 Black 3 Piston Assy 1 4 Shaft 1 5 Bearing retainer 1 Black No.

Operation in a vacuum condition Piping (Manifold) For the common exhaust type, pressurization or evacuation of the 3(R) port can cause a malfunction. For operation in a vacuum condition, use VT/O307V. Note that if the valve is used in an environment where the product is exposed to a large amount of dust, install a filter to the 3(R) port.

Cable wire color Terminal 1 Brown DC+ q 2 Not used N.C. w 3 Blue DC e 4 White IN: 1 to 5 V r Power supply / Output connector (8P) Power supply / Output connector (accessory) i u y t r e w q Pin no. Pin no. Terminal 7 Green CH4_OUT1 8 Yellow N.C.

Note 6) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it may result in a breakdown. Use a pipe tape for sealing. Recommened tightening torque for pressure regulator: R 1/8 = 7 to 9 N.m, R 1/4 = 12 to 14 N.m Note 7) Piping adapter, O-ring, Hexagon socket bolt, Hexagon socket bolt assembly. These are shipped together with products.

Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows. Design / Selection 1.