SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S40H-6000-A733"

AD Accessory (Option) GD Applicable model HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Screw flange (With companion flange) HAWF-141 HAWF-142 HAWF-200 HAWF-200 Auto drain AD402-04 AD600-06 AD600-10 Model Selection (Flow Capacity l/min (ANR)) JIS Symbol Model HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 50C 2000 6000 12000 12000 12000 18000 1000 70C 100C 180C Inlet air temperature

HA Accessory (Option) AT HAW2 HAW7 HAW22 HAW37 HAW55 HAW75 HAW110 Applicable model Screw flange (With companion flange) HAWF-141 HAWF-142 HAWF-200 HAWF-200 ID Auto-drain AD402-04 AD600-06 AD600-10 AMG Model Selection (Flow Capacity l/min (ANR)) AFF HAW2-04 HAW7-06 HAW22-14 HAW37-14 HAW55-20 HAW75-20 HAW110-30 Model 1000 70C 100C 180C 50C 2000 6000 12000 15000 22000 30 Inlet air temperature

Supply pressure MPa Supply pressure MPa Supply pressure MPa 1.0 1.0 1.0 1.0 1.0 1.0 Valve output pressure (MPa) Valve output pressure (MPa) Valve output pressure (MPa) 0.9 0.9 0.9 0.7 0.8 0.9 0.6 0.7 0.8 0.9 0.9 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.6 0.1 0.2 0.3 0.4 0.5 0.5 0.1 0.2 0.3 0.4 2000 4000 6000

PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 11 For Water Digital Flow Switch Series PF2W Refer to www.smcworld.com for details of products compatible with overseas standards.

Max. 150 NL/min 3000 NL/min PF2A703H 5.5 CFM 106.0 CFM 300 NL/min 6000 NL/min PF2A706H 10.5 CFM 212.0 CFM 600 NL/min 12000 NL/min PF2A712H 21.0 CFM 423.5 CFM : Analogue output is based on the rated flow range at normal condition. Displayed flow range is based on standard condition. Therefore, the range of rated flow and the displayed flow are different..

Features 2 Series PFMB Flow Switch Flow Rate Variations Applicable flow range [L/min] Series Minimum Detection Applicable method setting unit fluid 1 2 3 3 2 1 0.5 0 0.5 PFMV 0 0.5 0 1 0 3 Thermal Air N2 type (MEMS) 0.5 0.5 1 1 3 3 Applicable flow range [L/min] Applicable Detection Minimum Series fluid method setting unit 1 2 0.2 0.5 5 10 20 25 50 100 150 200 300 500 600 1000 2000 3000 6000

AMD150 AMD250 AMD350 AMD450 AMD550 AMD650 AMD850 Model Note) 200 500 1000 2000 3500 6000 12000 Rated flow (l /min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

PF3A703H Item Default Settings [P] Set value of OUT 1500 L/min [H] Hysteresis of OUT 150 L/min PF3A706H Item Default Settings [P] Set value of OUT 3000 L/min [H] Hysteresis of OUT 300 L/min PF3A712H Item Default Settings [P] Set value of OUT 6000 L/min [H] Hysteresis of OUT 600 L/min : For hysteresis, please refer to [F 1] Setting of OUT (page 31). 22 No.PF-OMU0002-D [Hysteresis

Note that the numbered scale markings are guidelines for adjusting the position, and not indicators of the dripping amount. 0.1 Pressure drop (MPa) 0.08 P1 = 0.7 MPa P1 = 0.5 MPa P1 = 0.3 MPa P1 = 0.1 MPa 0.06 0.04 0.02 0 0 2000 4000 6000 8000 Flow rate (L/min (ANR)) Caution 1. Check the dripping amount once a day.

For Air 1.6 1.4 Upstream pressure of valve P1 Downstream pressure P2 [MPa] 1.5 MPa 1.6 MPa 1.2 1.3 MPa 1.4 MPa Subsonic 1.0 Critical pressure 1.2 MPa 1.1 MPa 0.8 1.0 MPa 0.9 MPa 0.8 MPa Sonic 0.6 0.7 MPa 0.6 MPa 0.5 MPa 0.4 0.4 MPa 0.3 MPa 0.2 0.2 MPa 0.1 MPa 0 VXB215A D(H) 10 12000 14000 8000 2000 4000 6000 VXB215B E(H) 16000 14000 10 12000 8000 2000 4000 6000 VXB215C F(H) 10 2000 6000 8000

For Air 1.6 1.4 Upstream pressure of valve P1 Downstream pressure P2 [MPa] 1.5 MPa 1.6 MPa 1.2 1.3 MPa 1.4 MPa Subsonic 1.0 Critical pressure 1.2 MPa 1.1 MPa 0.8 1.0 MPa 0.9 MPa 0.8 MPa Sonic 0.6 0.7 MPa 0.6 MPa 0.5 MPa 0.4 0.4 MPa 0.3 MPa 0.2 0.2 MPa 0.1 MPa 0 VXB215A D(H) 10 12000 14000 8000 2000 4000 6000 VXB215B E(H) 16000 14000 10 12000 8000 2000 4000 6000 VXB215C F(H) 10 2000 6000 8000

Setting of OUT1 delay time at ON 0.01 s increment (0 to 60 s) 7 R/W OFF delay time U16 100 Y 0 ~ 6000 Setting of OUT1 delay time at OFF 0.01 s increment (0 to 60 s) Output mode U8 1 Y 0: HYS 1: Wind Setting of OUT2 output mode 1 R/W 1450 0X05AA 0: Normal output 1: Reverse output Setting of OUT2 output normal and reversed output 2 R/W Output type U8 0 Y OUT port pressure (OUT2) 1 R/W HYS

Annual cost reduction effect [Calculation conditions] Electric power cost: 1.55 yen/m3 [Work model] Working hours: 6000 h (250 days/year) Supply pressure: 1.0 MPa Set pressure: 0.2 MPa Comparison between IR3000-A and the current IR3000 Comparison between IR1000-A/IR2000-A and the current IR1000/IR2000 300 300 Annual cost of power consumed by compressor [1000 yen/year] 250 250 When 20 units

6000 0.8 MPa 0.5 MPa 0.8 MPa 0.5 MPa 4000 4000 0.3 MPa 2000 2000 0.3 MPa 0 50 100 150 200 250 300 0 50 100 150 200 250 300 Arm length [mm] Arm length [mm] Bore size: 63, Arm length: 200 mm, Operating pressure: 0.5 MPa With an arm length of 200 mm and an operating pressure of 0.5 MPa, according to the graph, the maximum clamping force is 2000 N.

Annual cost reduction effect [Calculation conditions] Electric power cost: 1.55 yen/m3 [Work model] Working hours: 6000 h (250 days/year) Supply pressure: 1.0 MPa Set pressure: 0.2 MPa Comparison between IR3200-A and the current IR3000 Comparison between IR1200-A/IR2200-A and the current IR1000/IR2000 300 300 Annual cost of power consumed by compressor [1000 yen/year] 250 250 When 20 units

A side B side COM 3 VFR540 5 A side B side COM Ground 3-5-3 4 Series VFR2000/3000/4000/5000/6000 Precautions Be sure to read before handling.

Recommended shim thickness) Arm length L: 8 in 0.08 0.04 0.12 For Asia For North America For Europe For France Special 800 Clamping force (lbf) 0.7 MPa 600 0.5 MPa 0.3 MPa 400 200 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 80 Arm length L: 250 mm 7000 6000 5000 4000 3000 2000 1000 0 Clamping force (N) 0.7MPa 0.5 MPa 0.3 MPa 0 1 2 2.5 3.5 3 4 5 6 7 8 9 Shim thickness (mm) (Ex.

Replace the element every 2 years or when the pressure drop becomes 0.1MPa, whichever comes first, to prevent damage to the element. 0.02 0.02 00 00 2000 4000 6000 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) AF20 Rc 1/4 AF50 Rc 1 0.10 0.10 P1 = 0.7MPa P1 = 0.5MPa P1 = 0.7MPa P1 = 0.5MPa 0.08 0.08 P1 = 0.3MPa Pressure drop MPa Pressure drop MPa P1 = 0.3MPa P1 = 0.1MPa 0.06 0.06

251 to1000st: , 1001st and up: Stroke length tolerance Standard Stroke Table Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Symbol 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000

(When reversed output is selected, the sub display (left) shows [n1L/n2L] and [n1H/n2H].) 16000 L/min 12000 L/min 20 L/min 6000 L/min Additional range 3 Blue DC(-) DC(-) WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.