IZTP43(-L) and IZTN43 (2pcs.), IZTP41(-L) and IZTB40 (2pcs.) Separate connection Example of connecting IZTC41(-L), IZTP43(-L) andIZTN43 Example of connecting IZTC41(-L), IZTP43(-L) and IZTN43 (4pcs.) Example of connecting IZTC41(-L), IZTP43(-L) and IZTN43 (2pcs.) , IZTP41(-L) and IZTB40 (2pcs.) 1-2.
1 u u x100 x10 x1 IP address setting switches Switch to set the 4th byte of the IP address by X1, X10 and X100. !7 i !2 i MS, NS Communication status LED Displays the status of the EtherNet/IPTM communication t o ENC z Encoder connector (16 pins) Axis 1: Connect the actuator cable. !0 MOT z Motor power connector (6 pins) !8 @1 !
Address setting switch (x10): Sets the 10 digit of the DeviceNet node address. Address setting switch (x1): Sets the 1 digit of the DeviceNet node address. Data Rate switch: Sets DeviceNet communication speed.
18 to 176 3.5 to 35.5 7 to 71 18 to 176 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Instantaneous Setting/display flow range 1.0 to 38.0 8 to 186 1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 Flow CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Setting/display flow range 0 to 9 ft3 x10
and X100. 7 x10 x1 8 MS, NS Communication status LED Display the status of the EtherNet/IP communication. 9 ENC1 Encoder connector (16 pins) Axis 1: Connect the actuator cable. 10 MOT1 Motor power connector (6 pins) 11 ENC2 Encoder connector (16 pins) Axis 2: Connect the actuator cable. 12 MOT2 Motor power connector (6 pins) 13 CI 1 2 Motor control power supply Motor control power supply
For actuators with a stroke more than 1000mm, set parameter PE02 (Feed function selection) to 0001 and the "Feed length multiplication (STM) (Multiplier)" value to x10. 3 59 - Configure target position (mm).
psig (0.014 to 0.7 MPa) SL5806 1 to 60 psig (0.007 to 0.4 MPa) Operating Parameters Delivery pressure Gas Source pressure Proof pressure (Inlet) Burst pressure Ambient and operating temperature Cv Select compatible materials of construction for the gas Vacuum to 300 psig (2.1 MPa) 2000 psig (13.8 MPa) 4000 psig (27.6 MPa) 40 to 160C (40 to 71C) (No freezing) 1) 0.4 2 x 10-11 Pam3/sec 2 x10
For actuators with a stroke more than 1000mm, set parameter PA05 (Feed function selection) to 0001 and the "Feed length multiplication (STM) (Multiplier)" value to x10. Set the feed length multiplication (STM) (Multiplier) of target position in parameter No. PA05 (Feed function selection). Parameter No.
For actuators with a stroke more than 1000mm, set parameter PA05 (Feed function selection) to 0001 and the "Feed length multiplication (STM) (Multiplier)" value to x10. Set the feed length multiplication (STM) (Multiplier) of target position in parameter No. PA05 (Feed function selection). Parameter No.
Display Description Details 1 P1, P2 EtherNet/IP communication connector Connect Ethernet cable. 2 MS, NS Communication status LED Display the status of the EtherNet/IP communication. x100 IP address setting switches Switches to set the EtherNet/IP communication IP address (0 to 255) by X1, X10 and X100. 3 x10 x1 OFF Power supply OFF 4 PWR Power supply LED (green) Green LED is ON Power supply
RD SD LRUN PW B RATE 131 8 115 80 x1 x10 STATION NO.
PW 0 0 0 1 1 1 9 9 9 PW LRUN 2 2 2 8 8 8 3 3 3 7 7 7 4 4 4 6 6 6 SD RD LERR. 5 5 5 L RUN SD RD x10 x1 24V 0V +24V 24G DA DB FG DG L ERR.
Status LEDs on unit for each output Use with Series (N)VFR, (N)VFS, (N)VZS, ISO valves. 14 N 16 0 IN313-AB1-X10 Allen-Bradley Remote I/O (RIO) compatible Controls up to 16 single solenoid valves. (A combination of single and double solenoid valves as long as the maximum number of solenoid does not exceed 16.)
ECAT ID EtherCAT ID 1999(1) EtherCAT ID: 0999 (Factory default 002) Setting EtherCAT ID x100 x10 x1 0 0 0 Value that setting by EtherCAT master device 0 0 1 1 0 0 2 2 (Factory default) 0 0 6 4 64 9 9 9 999 Caution Turn OFF the power supply while setting the switch.
OFF ON ON ON ON ON -20No.EX-OMN0034-B Station setting switch: Set the station number of SI unit Station number setting Address Station number x10 x1 0 0 Error (Default setting) 0 1 1 0 2 2 : : : 6 3 63 6 4 64 6 5 Error : : 9 9 : If a station number is set to 00 or over 65, the "LERR" LED will light up. The settable range depends on the number of occupied stations.
C37, Stainless Steel Body Type Port size Size Orifice diameter (mm) Model Maximum operating pressure differential psi (MPa) Flow-rate characteristics Weight AV (x10-6m2) Conversion Cv Pressurized port 1 131 (0.9) 1.0 0.04 0.96 C37: 65 Stainless steel: 2.1oz (60g) 1 VDW12 M5 58 (0.4) 1.6 0.07 1.70 102 (0.7) 1.6 0.07 1.70 C37: 115 Stainless steel: 3.5oz (100g) 2 VDW22 58 (0.4) 2.3 0.18 M5,
Address setting switch (x10): Sets the 10 digit of the PROFIBUS DP node address. Address setting switch (x1): Sets the 1 digit of the PROFIBUS DP node address. Settings 2 switch (8): Sets the 3rd digit of the PROFIBUS DP node address.
Those that exceed the standard stroke will have the long stroke dimensions. (2) Exclusive body (-X10)Add stroke. Stroke lengths that exceed standard are long stroke dimensions. 9 10 12 15 M5 X 0.8 M6 X 1.0 M8 X 1.25 10.5 12 14 17.5 M10 X 1.25 Basic (A, B, F and L are different between standard stroke and long stroke.)
key) Power supply connector (M12, 5 pins, plug, reverse key) BUS BUS 59.8 59.8 59.8 PWR PWR PWR Ground terminal 63 Ground terminal Ground terminal 63 63 EX250-SCA1A (CANopen) EX250-SEN1 (EtherNet/IP) EX250-SCN1 (ControlNet) Position indicator LED Position indicator LED Position indicator LED SI UNIT PWR CAN PWR(V) PWR NS SOL MS PWR(V) PWR SELECT ADDRESS 64.4 64.4 64.4 0 1 0 1 75.1 77.6 X10
-X10 . Auto Switch Guide Reed Switches/Solid State Switches For Rotary Actuators (Air Grippers) . Precautions. Before Operation .