25 MB MA HC HE KB KA LA LB LC PA PB PD PC ME MD MIS12-10 MC HD HA, HB JB JA N Model 48 38 28 39 29 19 MIS12-30 MIS12-20 13 10 7 6 4 3.5 17.5 11.6 2.3 M2.6 x 0.45 19 4 M4 x 0.7 6 11 5 2.5H9 0 +0.025 18 6 MIS20-30 MIS20-20 MIS20-10 7 40.5 30.5 20.5 52 42 32 8.5 17.5 4H9 0 +0.030 5 5 2.8 M3 x 0.5 26 6 M6 x 1 9 25 12 8 10 15 14 26 10 Series MIW/MIS Finger options Tapped on upper and lower faces
L dimension L dimension No. 6 7 8 2 3 4 5 1 0 7 185.5 0 98 2 3 4 5 6 7 1 0 0 8 198 1 110.5 6 7 8 4 5 2 3 1 1 9 210.5 123 2 M12 input block (n) 6 7 8 3 4 5 2 2 10 223 135.5 3 L dimensions 6 7 8 9 5 4 3 11 235.5 4 148 9 10 8 7 6 4 12 248 5 160.5 Connector type For M (m + n = 2 to 8) 10 8 9 7 5 173 6 10 11 9 6 11 10 7 12 8 Connector type For T (n = 1 to 8) 1686 Decentralized Serial Wiring (GW
6 t !3 !4 !2 r w e !0 o !9 !8 i !5 u !7 q !
Lists the history (Maximum 6 cases) of alarms that occurred in the past.
OFF ON ON ON ON ON -20No.EX-OMN0034-B Station setting switch: Set the station number of SI unit Station number setting Address Station number x10 x1 0 0 Error (Default setting) 0 1 1 0 2 2 : : : 6 3 63 6 4 64 6 5 Error : : 9 9 : If a station number is set to 00 or over 65, the "LERR" LED will light up. The settable range depends on the number of occupied stations.
Action D S Rod end threads Double acting Single acting (spring extended) Rod end female threads (4 without threads) Rod end male threads Nil M Table 2 Auto switch specifications Table 1 Standard strokes Action Bore size (mm) 4 6 8, 10 4 6 8, 10 Standard stroke (mm) 4, 6, 8, 10 4, 6, 8, 10, 15 4, 6, 8, 10, 15, 20 4, 6 4, 6, 8 4, 6, 8, 10 Load voltage Lead wire length (m) Indicator light Wiring
Q = D __ 4 6 _ 1000 Q = (D d) __ 4 6 _ 1000 Formula (1) .
3.5 6 x M2 x 0.4 thread depth 4 (A, B, C common view) 3 0 0.02 3 Open: 22, Closed 14 0 0.02 Open: 16, Closed: 10 2 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) 15: MHR2-15-A210 2 x M3 x 0.5 thread depth 6 (Thread for mounting attachment) Hexagon socket head cap screw M3 x 12 (3 included) Mass: 130 g Mass: 210 g +0.022 0 depth 6 3 x 3 (A, B, C common view) 6 x M3 x 0.5 thread
HRSH 090 6 Signal for the completion of preparation A signal is output when the circulating fluid temperature reaches the set temperature, when using contact input/output and serial communication. !0 !1 !2 !3 !4 !5 !6 HRSH HRSH No.
Model 6 6 6 ZH05DA ZH07DA 1/4" 1/4" 1/4" ZH05DA ZH07DA One-touch One-touch SUP. EXH. 6 6 8 ZH10DA 1/4" 1/4" 5/16" ZH10DA 8 10 10 ZH13DA ZH15DA 5/16" 3/8" 3/8" ZH13DA ZH15DA 10 12 12 ZH18DA ZH20DA 3/8" 1/2" 1/2" ZH18DA ZH20DA One-touch Oval release button is only available with 6. VAC. One-touch and screw-in connection SUP. VAC. EXH. Model SUP. VAC. EXH.
5 5 20 20 F7FFE -3276732766 0 1 0 0 4 Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 MSB AD LSB -31No.EX-OMN0037CN-A -32No.EX-OMN0037CN-A EX600-AM B M12 (5 )4 2 2 M12 (4 ) No. 1 LED 2 () 3 () 4 5 6 () -33No.EX-OMN0037CN-A 1 24 V() 24 V() 2 + 3 0 V() 0 V() 4 0 V() 5 FE FE 1M12 (4 ) 1 1 24 V NC
Extension Cable 6. Part Identification 22 6-1. Monosashi-kun with brake 6-2. Controller 7. Installation & Wiring 23 7-1. Installation 7-1-1 Installation of Cylinder 7-1-2 Installation of Controller 7-2. Wiring 7-2-1 The connection of Power Supply 7-2-2 The connection of Extension Cable 7-3.
Instance common service Service code Description 0Eh Get_Attribute_Single 10h Set_Attribute_Single -27No.EX-OME0015-F 6. Discrete Output Point Object (Class ID: 09h) 6-1. Class attribute ID Access rule Description Value 6-2. Class common service Service code Description 6-3.
N.C. type is recommended. 15 6.
6 @3 @4 e !7 w i t q A A @7 #3 @9 #0 #1#2 !8 !9 #4 @8 @6 !4 !5 Description Material Note Component Parts Description Material Note Component Parts No.
6 !7 !8 q w e r t y u i o !0 !1 !2 !3 !4 !
6, !8. 4 Piston rod Stainless steel 1 5 Piston Aluminum alloy 1 6 Cushion ring Rolled steel 2 Trivalent zinc chromated * Seal kits consist of items !3 to !6, !8 and can be ordered by using the seal kit number corresponding to each bore size. * The seal kit includes a grease pack (10 g for 32 to 50, 20 g for 63 and 80, 30 g for 100).
IDF60/70/80/90 Series 6.2 Reset the Thermal relay and High Pressure Switch 6-3 IDX-OM-X011 Chapter 6 Troubleshooting 6.2 Reset the Thermal relay and High Pressure Switch IDF190D/240D Series 6-4 IDX-OM-X011 Chapter 7 Documents Chapter 7 Documents 7.1 Specifications Models Item IDF190D IDF240D Standard condition (ANR) Note 1) 50Hz 32 43 60Hz 38 50 Air flow capacity m3/ min Compressor inlet