If operating with a small induction load such as a relay, wire as shown in the figure below. (In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1.
AR425 to 935 ARX q Body size 1 2 3 Symbol Description AMR w Set pressure range 0 0.005 to 0.2 MPa V V 0.01 to 0.2 MPa V 1 0.01 to 0.4 MPa V V V 2 0.01 to 0.8 MPa V V V + ARM ARP IR-A IR-A e Exhaust direction 0 Bottom exhaust V V V 1 Front exhaust V 2 Rear exhaust V + IR IRV r Pipe thread type Nil Rc V V V N NPT V V V F G V V V + VEX 01 1/8 V 02 1/4 V V 03 3/8 V 04 1/2 V + SRH
AR425 to 935 ARX q Body size 1 2 3 Symbol Description AMR w Set pressure range 0 0.02 to 0.2 MPa V V V 1 0.02 to 0.4 MPa V V V 2 0.02 to 0.8 MPa V V V + ARM ARP e Exhaust direction 0 Bottom exhaust V V V 1 Front exhaust V 2 Rear exhaust V + IR-A IR-A IR r Pipe thread type Nil Rc V V V N NPT V V V F G V V V + IRV VEX 01 1/8 V 02 1/4 V V 03 3/8 V 04 1/2 V + SRH t Port size SRP a
If operating with a small induction load such as a relay, wire as shown in the figure below. (In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1.
consists of a left support and a right support.
110 V [115 V] 200 V 220 V [230 V] 4(A) (B)2 2(B) (A)4 Apparent power (VA) AC 5(R1) (R2)3 1 (P) (R1)5 1 (P) 3(R2) Diode (DIN terminal, Varistor when non-polar types) LED (Neon light when AC with DIN terminal) 3 position exhaust center 3 position exhaust center Surge voltage suppressor Indicator light 4(A) (B)2 2(B) (A)4 Common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
G T L S M kit (Flat ribbon cable with terminal block) kit (Terminal box) kit (Lead wire) kit (Serial transmission unit) kit (Multi-connector kit) Number of pins: 20 (VQ2000 only) 2-4-113 Valve Specifications Sonic conductance Type of actuation Voltage Electrical entry Manual override C [dm3/(sbar)] 4/2 5/3 (A/B R1/R2) 12 V 24 V DC 100 V 110 V AC 200 V 220 V AC 50/60 Hz 50/60 Hz Push type
Install a micro mist separator or super mist separator on the outlet side (end terminal) of the membrane air dryer (unit). Grease is applied inside a regulator used in the unit (V type).
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.
, D-A93(V), D-A96(V) (mm) Lead wire entries outside A A Model Mounting Switch operating range A B A B A B 54 MXY6 34 59 5 MXY8 MX 39 67 MXY12 MTS 47 MY Solid State Switch D-M9B(V), D-M9N(V), D-M9P(V) Lead wire entries inside (mm) B B CY Model Mounting Switch operating range A B A B A B 50 MXY6 2 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main
500 600 V(mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 Vertical Transfer 12 50 B B B 20 A 10 A A 40 H W(kg) W(kg) H 8 W(kg) 15 30 6 10 20 4 5 2 10 0 0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100
When a surge generating a load such as a relay or solenoid is directly driven, use a type of switch with a built-in surge absorbing element. 4. Since the type of fluid varies depending on the product, be sure to verify the specifications. The switches do not have an explosion proof rating. To prevent a possible fire hazard, do not use with flammable gases or fluids. 5.
12 V Reed auto switch Solid state auto switch 12 V IC circuit Diagnostic indication (2-color indicator) 5 V, 12 V Relay, PLC Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equiv.)
(example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5V, the detected voltage by the A/D converter becomes 5(V) x 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V). Output impedance The operation principle of the switch output. Normal output and reverse output can be selected.
NBR FKM C S A Note 2) T N V Symbol Number of arranged elements Note 1) Not used with fiber elements.
NBR FKM C S A Note 2) T N V Symbol Number of arranged elements Note 1) Not used with fiber elements.
Analogue output A B Voltage output 1 V 5 V Current output 4 mA 20 mA Rated flow range Model Min.
A96V A96 5 V Grommet Yes 12 V A93 A93V 24 V 100 V Relay, PLC 2-wire 3-wire (NPN) M9N M9NV IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) M9B M9BV 2-wire 12 V F9NW F9NWV Relay, PLC 3-wire (NPN) Diagnostic indication IC circuit 5 V, 12 V 24 V Grommet Yes 3-wire (PNP) F9PW F9PWV (2-color display) F9BW F9BWV Improved water resistance (2-color display) 2-wire 12 V F9BA Though it is possible