200 300 500 25 50 100 200 300 500 Outlet air flow rate L/min(ANR) 6 12 25 50 60 86 3 6 11 22 29 50 Purge air flow rate L/min(ANR) *Note3 Inlet air pressure MPa 0.7 Inlet air temperature oC 25 Inlet air saturation temperature oC 25 Ambient temperature oC 25 Dew point indicator purge air flow rate 1 L/min (ANR) {In the case of inlet air pressure 0.7MPa} *Note4 Regulator construction (about

NPN) C76 IC 5 V Grommet C73 B54 C73C A33A A34A A44A B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW H7BA H7NF 100 V Reed switch Solid state switch Relay, PLC 100 V, 200 V Yes Yes Connector 12 V 2-wire 24 V PLC Terminal conduit 100 V, 200 V Relay, PLC Grommet DIN terminal Diagnostic indication (2-color) 3-wire (NPN) 3-wire (PNP) IC 5 V, 12 V Grommet 12 V 2-wire Connector 3-wire (NPN) 2-wire

200 300 400 500 600 700 800 900 1000 0 0 100 200 300 400 500 600 700 800 900 1000 Flow rate l/min(ANR) Flow rate l/min(ANR) ARX21-01 ARX21-02 0.35 0.35 0.30 0.30 Downstream pressure MPa Downstream pressure MPa 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 Flow rate l/min(ANR) Flow rate l/min(ANR) Pressure

Metric sizes 6 8 10 12 Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 (free) flow Effective area mm 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.

2.2 3.7 5.5 7.5 5.5 3.7 2.2 1.5 0.75 (for screw style) (kW) Single phase, AC100/100 to 110 Single phase, AC100/100 to 110 Single phase, AC200/200 to 220 Power source (V) 50/60Hz 165 195 310 360 330 370 165 195 175 210 210 250 200 230 320 385 335 380 210 240 200 230 170 200 175 210 165 195 165 195 165 195 165 195 165 195 50Hz 60Hz 50Hz 60Hz AC 100V AC 200V Power consumption (W) Note2) 50

Barb elbow Barb fitting Barb one-touch Reducer Port size M3 x 0.5 M5 x 0.8 Tubing size 3.2 4 Port size M3 x 0.5 M5 x 0.8 Fitting size 3.2 4 Piping for compact actuator Scale :100% Scale :100% Scale :100% Piping for compact pressure sensor 4 x 7 Scale :100% Sectional area 113.04mm2 4 75% Reduction 2 x 7 Sectional area 2 28.26mm2 Easy size reduction Reduction of the tubing size from standard

120 140 0 10 20 30 40 50 60 70 80 90 100 Flow rate l/min (ANR) Flow rate l/min (ANR) SRP1-01 SRP1101-01 Conditions/Upstream pressure: 0.5MPa Conditions/Upstream pressure: 0.7MPa 0.25 0.50 0.20 0.40 Downstream pressure MPa Downstream pressure MPa 0.15 0.30 0.10 0.20 0.05 0.10 0.00 0.00 0 20 40 60 80 100 120 140 160 180 200 0 20 40 60 80 100 120 140 Flow rate l/min (ANR) Flow rate l/min (ANR

Option Part no. 1 Bracket A ZS24A With 2 pcs. of mounting screws 1 Bracket D ZS24D With 2 pcs. of mounting screws 1 Panel mount ZS24E 1 ZS24F Panel mount + Front protection cover 1 For General Fluids High Precision Digital Pressure Switch Series ZSE50F/ISE50 Specifications ZSE50F (Compound pressure) 100 to 100kPa 100 to 100kPa 500kPa 0.1 0.001 0.001 0.02 1 0.1 ISE50 (Positive pressure)

Leave a space of 100 mm or more for maintenance on the valve guide side (opposite side from the knob). 3. When the product is installed between a solenoid valve and an actuator, select a backflow function type. Caution 1. Be sure to install a safety device to prevent damage or malfunction of the outlet side components when the output pressure exceeds the set pressure value. 2.

Rated voltage CE-compliant For DC 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC B: Locking slotted type CE-compliant For AC (50/60Hz) 1 2 3 4 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] Electrical entry 24, 12, 6, 5, 3 VDC / 100, 110, 200, 220 VAC Grommet L plug connector M plug connector G: Lead wire length 300 mm L: With lead wire (Lead wire length 300 mm) M: With lead wire (Lead wire

IS400-1 (1S-1) IS400-2 (1S-2) Model Port size B J A C D E F G H I , 1 4 1 2 1 1 AL800-12 to 14-1 AL900-20-1 431 (481) 437 (487) 3 x M5 x 0.8 x depth 6 3 x M5 x 0.8 x depth 6 230 230 ( ): With float switch 117 117 60 60 100 100 2 59 63 166 162 73 73 1046

Leave a space of 100 mm or more for maintenance on the valve guide side (opposite side from the knob). 3. When the product is installed between a solenoid valve and an actuator, select a backflow function type. Caution 1. Be sure to install a safety device to prevent damage or malfunction of the outlet side components when the output pressure exceeds the set pressure value. 2.

Standard equipment 1/2B 3/8B 1B (3) Accessory 11/2B Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) Based on discharge rate and discharge temperature (70C) of screw type compressors. Note 3) The accessories should be mounted by user.

Resistance to ground should be 100 ohms or less. Troubleshooting 1 2 Cable color: Signal name Pin No.

Ratio of discharge amount to fresh water (%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity (mPa s) mPas Silicone oil Lubricant Vegetable oil Water 60 to 80 1 6080 340 950 1500 3150 9800 Viscosity (mPa s) cp 0 100 1000 10 150 | 2650 45 | 2 3000 4500 Tomato juice Honey Medical barium Wooster source Cutting oil 4500 45 2000 to 3000 8 - 8.

Ratio of discharge amount to fresh water(%) 100 90 80 70 60 50 40 30 20 10 0 1000 100 10 1 Viscosity(mPa s) mPas Silicone oil Lubricant Vegetable oil Water 1 60 to 80 340 950 1500 3150 980 0 Viscosity (mPa s) 0 100 1000 10 Medical barium Cutting oil Tomato juice Honey Woosterource 4500 45 150 2000 to 3000 2650 8 - 8.

Between external terminals and body Insulation resistance 500 VDC, 2 M or more Between external terminals and body Operating environment No corrosive gas and no dust Standard CE marking EX120-SCM#: 100 g or less EX121-SCM#: 120 g or less (Contain the accessories) EX122-SCM#: 110 g or less Weight Accessory Power supply connector 1 pc.

Air and liquid leakage Check if air liquid are leaking from the piping. 11 Noisy. Product failure Replace the product. -22No.PS-OMO0002-A Error indication function This function is to display error location and content when a problem or an error occurs. Error Display Error Type Troubleshooting Method The set data has been changed under some influences.

Subordinate position 12bit b11b0 corresponds to 100%FS of pressure. The pressure setting is assumed that data 1332h of 120%FS is a limit value. The accuracy guarantee is to 100%FS. It might response to PLC a very high numerical value such as Fh in around outlet pressure 0. It is because of recognition that pressure is a minus side due to the erro, and this is not a failure.

Solenoid Specifications 100, 200 VAC, 50/60 Hz; 24 VDC Coil rated voltage How to Calculate the Flow Rate 15 to +10% of rated voltage Allowable voltage fluctuation For obtaining the flow rate, refer to page 31-10.