Series: 3 (VQ30), Stations: 10 Stations, Option: D (DIN Rail Mounting), Thread: 00F (G3/8)
Series: AF, Body Size: 60, Thread: Rc, Port Size: 1, Mounting: None, Flow Direction: Left to Right, Pressure Unit: Unit on Product Label: MPa, °C
Series: AF, Body Size: 50, Thread: Rc, Port Size: 1, Mounting: None, Flow Direction: Left to Right, Pressure Unit: Unit on Product Label: MPa, °C
Body Size: 60, Back Flow: w/o Backflow Function, Thread: Rc, Port Size: 1, Mounting: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 50, Back Flow: w/o Backflow Function, Thread: Rc, Port Size: 1, Mounting: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 60, Back Flow: w/o Backflow Function, Thread: Rc, Port Size: 1, Mounting: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Pressure Units: Unit on Product Label: MPa,°C, Pressure gauge in SI units: MPa
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
) Ambient temperature 104F (40C) 10 10 8 8 Ambient temperature 113F (45C) Ambient temperature 113F (45C) 6 6 4 4 2 2 0 0 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] Circulating fluid temperature F [C] Circulating fluid temperature F [C] HRS150-W -20/40(50 Hz) HRS150-W -20/40(60 Hz) 20 20 Facility water temperature 90F (32C)
Specification for Option L 10 1 Safety instructions . 10 1 10 2 Specification . 10 1 10 3 Installation of heavy duty auto drain . 10 2 10 4 Maintenance . 10 2 Chapter 11 Specification for Option M 11 1 Safety instructions . 11 1 11 2 Specifications . 11 2 11 3 Installation of motor type auto drain . 11 3 11 4 Electric circuit . 11 3 Chapter 12 Specification for Option R 12 1 Safety instructions
Cooling Capacity HRS100-A-20/40(50 Hz) HRS100-A-20/40(60 Hz) 14 14 12 12 Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 40C Ambient temperature 32C Ambient temperature 40C 8 8 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature
(Maximum 10 stations) Example) IITV00-05-07 02 03 2 stations 3 stations Indicate part numbers in order starting from the first station on the D side. 10 10 stations Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. Note) A DIN rail with the length specified by the number of stations is attached to the manifold.
Enable Generates an error. 1 -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Set the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.
L/min 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 12 to 24 VDC 10% 24 VDC 10% Temperature characteristics (25C reference) 3% F .S. (15 to 35C) 5% F .S. (0 to 50C) 2% F .S.
PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521 30 250 Analogue output (Fluid temperature) A B C D Voltage output 0.6 V 1 V 5 V 5.4 V Current output 2.4 mA 4 mA 20 mA 21.6 mA Be sure to connect to a flow sensor with a temperature sensor. -70No.PF-OMN0012-H Dimensions Front protective cover + Panel mount adapter -71No.PF-OMN0012-H Cut-out dimensions for panel mounting : The
190 13 13 16 16 19 55 66 72 92 98 63 76 76 90 90 7.5 4 4 5 5 63 76 76 90 90 10 10 10 10 10 AMF150 AMF250 1/2 3/8, 1/2 AMF350 3/4 AMF150SAME, #1 AMF250SAME, #2 AMF350SAME, #3 4.6-31 Odor Removal Filter Series AMF Dimensions: AMF450 to AMF850 HAl AT IDl AMG AFF AMl M Dimensions with mounting bracket Model Port size (Nominal size B) A H B C D E F G I 221 J 25 K 10 L 14 N 90 O 55 P 110 Q 50
ZS-26-E (4 pcs. per set) Connector 3 Multi-channel Controller Series PSE200 Specifications Model PSE200 NPN open collector PSE201 PNP open collector Output specification 12 to 24VDC 10%, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage 55mA or less (Current consumption for sensor is not included.)
The right side of the common port provides plug. 4.1-75 VVXA31/32 Dimensions Stations 2 3 4 5 6 7 8 9 10 Model L L1 L2 L1 L2 96 84 126 108 132 120 172 154 168 156 218 200 204 192 264 246 240 228 310 292 276 264 356 338 312 300 402 384 348 336 448 430 384 372 494 476 VVXA31 VVXA32 Symbol Model M 45.5 50.5 N 69 76 K 6 9 G 24 25 H 30 40 J 36 46 F 33 34 C 9 10 D 22 24 E 59 66 B 20 22 A 40 44
Symbol Symbol Applicable tubing size (mm) 4 x 3 3 x 2 6 x 4 4 x 3 3 x 2 6 x 4 4 x 3 3 x 2 10 x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 4 x 3 3 x 2 10 x 8 8 x 6 12 x 10 10 x 8 12 x 10 10 x 8 8 x 6 6 x 4 3 x 2 12 x 10 19 x 16 12 x 10 19 x 16 12 x 10 10 x 8 6 x 4 19 x 16 19 x 16 25 x 22 19 x 16 25 x 22 19 x 16 12 x 10 25 x 22 Applicable tubing size (inch) 1/8" x 0.086" 1/4" x 5/32" 3/16" x 1/8" 1/8
equipment to 20 A or less when selecting 0 to 10 V.
Note 2) As for D-P4DWtype, band mounting style, the switch mounting bracket and the auto switch have to be ordered separately. For details, refer to page 11. Note 3) For 2-color display, mount the switch in the middle of the green indication. 10 Auto Switch Mounting Bracket / Part No.