Pressure/3000~4000-6 FloatType, Attachment: None, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: None, Option 3: Name Plate, Caution on Bowl
Pressure/3000~4000-6 FloatType, Attachment: None, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: None, Option 3: Name Plate, Caution on Bowl
Pressure/3000~4000-6 FloatType, Attachment: None, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: None, Option 3: Name Plate, Caution on Bowl
Pressure/3000~4000-6 FloatType, Attachment: Residual Pressure Relief 3 Port Valve, Option 1: 0.2MPa + Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: None, Option 3: Name Plate, Caution on Bowl
Pressure/3000~4000-6 FloatType, Attachment: None, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: -, Option 3: -
Pressure/3000~4000-6 FloatType, Attachment: None, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: -, Option 3: -
Pressure/3000~4000-6 FloatType, Attachment: None, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: -, Option 3: -
Pressure/3000~4000-6 FloatType, Attachment: Check Valve + Pressure Switch, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: Flow Direction: Right->Left, Option 3: Name Plate, Caution on Bowl
Pressure/3000~4000-6 FloatType, Attachment: Check Valve + Pressure Switch, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: None, Option 3: Name Plate, Caution on Bowl
Pressure/3000~4000-6 FloatType, Attachment: Check Valve, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: Flow Direction: Right->Left, Option 3: Name Plate, Caution on Bowl
Pressure/3000~4000-6 FloatType, Attachment: Check Valve + 3 Port Residual Pressure Release Valve, Option 1: Lubricator w/Drain Cock + Metal Bowl w/Level Gauge, Option 2: None, Option 3: Name Plate, Caution on Bowl
Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: IL (I/O-Link), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 2 [1/4 (1000,2000,3000)], Accessory: None, Cable Connector: N (w/oCable Connector)
Model: 30 (4000 L/min), Pressure Range: 5 (0.005~0.9MPa), Power Voltage: 0 (24VDC), Input Signal: IL (I/O-Link), Monitor Output: For Input Signal/Communication Model Types 40, CC, DE, PR, RC and IL Only, Thread: N (NPT), Port Size: 4 [1/2 (3000)], Accessory: B (Flat Bracket), Cable Connector: N (w/oCable Connector), Pressure Display Unit: 4 (PSI)
-58.02 [Calculation example] (1) Conversion from the process data to the pressure measurement value (For ISE70 series, unit specification MPa and PD = 2000) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25 [MPa] (2) Conversion from the pressure measurement value to the process data (For ISE70 series, unit specification MPa and Pr = 0.75 [MPa]) (PD) = (Pr b) / a = [0.75 (0.25)]/0.00025 = 4000
580.15 [Calculation example] (1) Conversion from the process data to the pressure measurement value (For ISE70G series, unit specification MPa and PD = 2000) Pr = a (PD) + b = 0.00025 2000 0.25 = 0.25 [MPa] (2) Conversion from the pressure measurement value to the process data (For ISE70G series, unit specification MPa and Pr = 0.75 [MPa]) (PD) = (Pr b) / a = [0.75 (0.25)]/0.00025 = 4000
If it exceeds the guide of 4000 to 5000Hrs (in super-dry air, 300Hrs), the pilot valve may have reached its life expectancy, therefore, please replace it. Failure phenomenon Possible causes Countermeasures (Page 10) The pressure can not be 1 Even though the signal goes up, the pressure does not increase. Supply pressure and/or pilot pressure (for external pilot type) is not high enough.
20 s 10 s 5 s Max. 2 s 1 s Min. 0.5 s 0.2 s 0.1 s 0.05 s 0.02 s 0.01 s 6000 100 125 200 300 400 500 700 1000 1500 2000 30004000 10 600 5000 7000 Current (% for breaker capacity) For HRS090--20-B, HRS090--404h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000
If it is a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min 30s 20s Operating time Max. 10s 5s 2s Min. 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% for breaker capacity) Breakers operating characteristic
2001 to 3000 (25 to 40) 2001 to 5000 (50, 63) 25, 32, 40, 50, 63 100 to 1000 10 to 100 20, 25, 32 10 15 20 25 100 to 300 100 to 500 100 to 600 100 to 800 301 to 500 501 to 750 601 to 1000 801 to 1200 10, 20, 30, 40, 50 75, 100, 125, 150 10, 15 CY1H CXSW 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 20, 25, 32 ML1 25 32 1001 to 1200 1001 to 1500 25, 32, 40 100 to 1000 1001 to 2000 2001 to 4000
Three-phase type IDF TR 5 1700 Capacity Power supply voltage Symbol Applicable air dryer Capacity Symbol Inlet voltage Outlet voltage Type 1700 IDF22E-30, IDF37E-30 IDU22E-30, IDU37E-30 1.7 kVA 5 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 200 VAC (50 Hz) 200, 220 VAC (60 Hz) Threephase 6 380, 400, 415 VAC (50 Hz) 380 to 440 VAC (60 Hz) 4000 IDF55E-30, IDF75E-30 IDU55E-30, IDU75E-30 4 kVA 7000