Please contact SMC for further details. 2 Based on the JIS B 8419:2010 dynamic performance test (Coil temperature: 20C, pressure: 0.5 MPa, at the rated voltage) 3 Impact resistance: No malfunction occurred when it was tested in the axial direction and at a right angle to both the main valve and the armature in both an energized and de-energized state, once for each condition.
NO OFF n-2 n-1 Real-time flow rate Flow rate conversion Normal condition: 0C, 101.3 kPa, dry air Standard condition: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these conditions.
response frequency Green LED (stable detection) Red LED (unstable detection) Red LED (lights up when ON) Indicator light Ambient temperature 10 to 55C 25 to 70C Environmental resistance Ambient humidity 45 to 85% RH Power line: 240Vp, pulse width of 0.5s Noise resistance Temperature characteristics Voltage characteristics Detecting distance fluctuation Within +15/10% of detecting distance at 20C
TISA01BU-20X4 Made to Order eThe value of the min. bending radius is at a temperature of 20C and O.D. variable rate 10% max.
Flow rate conversion PF2 NO OFF n-2 n-1 High flow rate Basic state: 0C, 101.3 kPa Standard state: 20C, 101.3 kPa, 65%RH (ANR) Switchable between these states.
/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 460 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.25 0.3 0.25 0.25 0.2 Free flow 0.2 0.3 0.2 0.3 0.4 Note) Flow rate values are at a pressure of 0.5 MPa and a temperature of 20C
type Meter-in type Inch size 3/16" 5/16" 3/8" Indication symbol 1/4" Flow rate (L/min (ANR)) 100 180 230 260 390 460 660 790 920 1580 1710 Controlled flow Free flow Sonic conductance dm3/(sbar) 4.4 4.8 0.28 0.50 0.64 0.72 1.1 1.3 1.8 2.2 2.6 Symbol Critical pressure ratio 0.2 0.25 0.3 0.25 0.25 Controlled flow Free flow 0.4 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at 0.5 MPa and 20C
When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXD21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.)
The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.
(Coil temperature: 20C, at rated voltage, without surge suppressor) Note 2) When operating the locking type manually, apply torque of 0.2 Nm or less. Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition.
The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.
The value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Furthermore, abnormal temperature rises caused by adiabatic compression may result in the burst of the tube.
10 6 (m 2 ) VX32 AC (Full wave rectification) 50/60 10 8.5 60 1 3 5 0.08 1.5 1.0 0.6 220 1.9 VX311 -00 DC 8.5 60 11 60 9.5 50 1 3 5 0.16 0.5 0.3 220 3.8 VX312 -00 50 55 22 60 47 18 AC 0.6 370 VX3225-00 2.2 0.19 4.6 VX33 1.0 530 VX3325-00 AC (Full wave rectification) 50/60 14 11.5 60 1 3 5 0.24 DC 11.5 60 0.3 0.2 5.8 220 1.0 VX313 -00 Note) They are values in an ambient temperatue of 20C
Metric sizes 6 8 10 12 ASS Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 ASR (free) flow Effective area mm2 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
ASD330F CM2 VZ500 TU0604 1 m AN11001 25 Cylinder size 32 Values at 0.5 MPa and 20C.
Note) l/min (ANR) is for reference conditions of 20C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp.
Connector structure ZSE/ISE40, 80 Series Available Mounting Options Series IP40 IP65 20 20A 20B(-L) 20C With waterproof cover (20B, 20C) Lead wire Mounting Available Mounting Options Series Bracket A Bracket B Bracket C Panel mount 20 20A 20B(-L) 20C The bracket configuration allows for mounting in four orientations.
(Variation: 10%) Note 2) The value at ambient temperature of 68F (20C) and when the rated voltage is applied. The value depends on the ambient environment. This is for reference. Note 1) Power consumption, Apparent power: The value at ambient temperature of 68F (20C) and when the rated voltage is applied.
When the ambient temperature is 20C 5C and rated voltage is applied. Changing coils from AC to DC and vice versa is impossible, because of different core shapes. VXP21 0, 22 0, 23 0 are possible to exchange coil from AC to DC, but impossible from DC to AC. (Hum sound may generate because of no shading coil for DC.