Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: w/Bracket
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: w/Bracket, Calibration
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: w/Bracket, Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: w/Bracket, Calibration
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: w/Bracket
Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: w/Bracket
M5 x 20 Hexagon socket head cap screw Tightening torque: 3.5 0.5 Nm J D side G1/4 port part Tightening torque: 10 1 Nm K G e w q Note) H r q w e Note) e w q Note) F q w E C A U side B D M5 x 20 Hexagon socket head cap screw Tightening torque: 3.5 0.5 Nm Block Assembly C: 2 port valve manifold block assembly Manifold block assembly for gate valve D: 3 port valve manifold block assembly
Key-lock set data which is set in 5.8.5 Command:LOC Key-lock setting (W) is not the object to store.
How to order L E C C G 2 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions (4) Branch connector i. How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 71 - 8.
LED flashes when the station number or communication speed settings have changed during communication (the L RUN LED will turn on and the SI unit will operate according to the new settings once power is restored). L ERR.
200 LX5 + 200 LX3 + 200 LX5 + 200 LX3 + 200 1 2 3 1 2 3 1 2 1 2 1 2 3 to 90 3 to 90 3 to 63 3 to 90 3 to 66 3 to 44 3 to 90 3 to 40 3 to 45 3 to 35 3 to 35 3 to 30 4 2.5 6 4 8 5 10 6.5 12 8 B (Black), W (White), R (Red), BU (Blue), Y (Yellow), G (Green), C (Transparent), YR (Orange) L* is calculated by the number of coils (N) x O.D. 10Clean Series (Example) 10-TCU0425B-1 TUB-11 Polyurethane
Motor output [W]/Size [mm] 750/80 Motor type AC servo motor200 VAC Encoder Absolute 22-bit encoderResolution4194304 p/rev Horizontal 135 Power consumption [W] *7 Vertical 150 Horizontal 15 Stnadby power consumption when operating [W] *8 Vertical 45 power [W] *9 Max.1100 Type *10 Non-magnetizing lock specifications 24 VDC Rated voltage [V] Power consumption at at20 [W] *11 Holding force [N
Ejector Unit ZQ105 5 EA 1U K1 L G q w e r t y u i o !0 !1 !2 !4 !3 q Nozzle nominal size w Exhaust type 05 07 10 1U 3M With silencer for single unit 0.5 With silencer for manifold 0.7 1.0 e Solenoid valve combination (Refer to Table (1).) r Pilot valve (Refer to Table (1).) t Solenoid valve rated voltage (Refer to Table (1).)
Note 2) Bowl assembly for AFD30 to AFD40-06 includes a bowl guard (steel band material). 14-2-44 Micro Mist Separator Series AFD20/30/40 Dimensions AFD20 Bracket (Option) L D G F K M J E B H OUT IN C OUT F.R.L.
Note 2) Bowl assembly for AFM30 to AFM40-06 includes a bowl guard (steel band material). 14-2-41 Series AFM20/30/40 Dimensions AFM20 Bracket (Option) L G K D F M J E B H OUT IN C Port size OUT o s Drain Min. clearance for maintenance 45 A L AFM30/40/40-06 Bracket (Option) A D G F K M J C B E H OUT IN OUT Port size Drain Min. clearance for maintenance AFM30: 50 AFM40: 75 P AFM20 AFM30, AFM40
Cup W W Vertical lifting Horizontal lifting This type of application should Gripping generally be avoided. This product has 4 pneumatically connected cups per ejector. If one cup fails to operate, all other cups cannot grip the object. Safety measures needs to be taken to prevent falling of workpiece during transfer of the object.
If there is no accumulation of condensate in the bowl q at this time, the float w will be pulled down by its own weight, causing the valve r, which is connected to the lever e, to seal the valve seat t. !0 When there is an accumulation of condensate in the bowl: The float w rises due to its own buoyancy and the seal at the valve seat t is interrupted.
For actuators with external stopper, the rotation end can be set within the ranges shown in the drawing by adjusting the stopper bolt. c l o r e c t k n w u o i s C e CRB2 CRBU2 CRB1 MSU B port A port C e l o s c i w k CRJ Basic type For 90 and 100 For 180 and 190 CRA1 Single flat Single flat CRQ2 MSQ MRQ D+10 0 B port A port B port A port +8 0 00 20t 1 0 t 9 fla la gle e f gl sin sin of