Number of mountings CXTl12 5 20 15 10 2 pcs. 10 10 25 to 5 20 15 5 1 pc. 10 10 25 CXTl25 5 15 10 10 2 pcs. 10 15 20 CXTl 32 40 5 15 10 5 1 pc. 10 10 20 (mm) D-F7lW D-J79W D-F9BAL D-F7NT D-F79F Auto switch model D-A7l D-A8l D-A73C D-A80C D-A7lH D-A80H D-F7l D-J79 D-F7lV D-J79C Applicable model D-F7lWV D-A79W D-F7LF Number of mountings 2 pcs. 5 10 15 15 20 20 25 CXTl 32 40 1 pc. 5 5 10 15 15
A1 B1 (13.5) A6 B6 1 2 Nil Robotic cable (Flexible cable) S Standard cable Connector D (14.7) 15 16 Connector A (30.7) L (11) (10) Connector A terminal no. B-1 A-1 B-2 A-2 B-3 A-3 Connector C terminal no. Weight Signal Cable color Product no.
External view and descriptions of auto switch unit Mounting Procedure
Type Auto switch model Applicable magnetic field Electrical entry Indicator light Wiring (Pin no. in use) Load voltage Lead wire length Applicable load D-P3DWASC 2-wire (34) Pre-wired connector 0.3 m Relay, PLC Note 1) D-P3DWASE 2-wire (14) D-P3DWA Grommet 2-wire 0.5 m D-P3DWAL 3 m D-P3DWAZ 5 m AC magnetic field (Single-phase AC welding magnetic field) Solid state auto switch 2-color indicator
Parameter Classification . 15 2.4.2 Notation for Parameters . 16 2.4.3 Setting Parameters. 16 2.5 Monitor Displays. 16 2-1 2 P a n e l D i s p l a y a n d SigmaWin+TM 2.
or solid state), 30 msec or more -RT/SV/XY PNP open collector 2 output + Copy function Max.30 V, 80 mA Residual voltage: 1.5 V or less -18No.PF-OMU0007-D Example for wiring for accumulated pulse output NPN open collector 2 output PNP open collector 2 output -19No.PF-OMU0007-D Flow Setting Default settings When the flow exceeds the set value, the switch will be turned on.
B A A B 1 Chromic acid (25%, 70C) B D D A A B 2 Boric acid Inorganic salt B D A A B A 3 Sulfuric acid (30%, Room temperature) D D A A B A 4 Phosphoric acid (50%, Room temperature) D A A B B A 5 Ammonium hydroxide B A A B B D 6 Sodium hydroxide (30%, Room temperature) Inorganic alkali A D C D A A 7 Calcium hydroxide A A A D C A 8 Magnesium hydroxide A A A B B A 9 Acetylene A A A A A A 10
OUT1 ON : Green OUT1 OFF: Red -28No.PS-OMU0003-D [F 2] Setting of OUT2 Page 34 Same setting as [F 1] OUT1.
81No.PS-OMU0006-D Panel cutout dimensions Mount individually More than 2 pcs.
Most sensitive position 6 DC () Blue D-F9V Mounting screw M2.5 x 4l D-F9B, F9BV 4.3 Slotted set screw Indicator light 2 DC (+) Brown 20 2.7 2.8 4.6 DC () Blue 3.8 3.1 6.2 4 Most sensitive position 6 31 2-Color Display Solid State Switches/Direct Mount Type D-F9NW(V), D-F9PW(V), D-F9BW(V) Auto Switch Specifications Grommet D-F9W, D-F9WV (with indicator light) Auto switch part no.
) LE-CSB-SA 0.3 LE-CSB-SA 2 to 10 HRZFEV-A(CL3)AWG20 2 cores LE-CSB-SB 2 to 10 34.6 AWG20 2 21/0.18 1.35 4.7 0.1 or less Lock cable LE-CSB-RA 2 to 10 (Note 5) (Note 4) RMFES-A(CL3X) AWG20 2 cores LE-CSE-RB 2 to 10 39.0 2 110/0.08 1.37 4.5 0.3 AWG20 or less Note 1. d is as shown below. d Insulation sheath Conductor 2.
Applicable model: D-A73, A73H, A73C, C73, C73C, E73A, Z73 D-R73, R73C, 97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) When using a 2-color indicator type auto switch (D-A79W, A59W and B59W), the auto switch will constantly remain ON if the connections are reversed.
D-F8N, D-F8P 0.15mm2 x 3 wire (Brown, Black, Blue) D-F8B 0.18mm2 x 2 wire (Brown, Blue) Note 1) Refer to page 14 for auto switch common specifications. Note 2) Refer to page 14 for lead wire lengths.
Note 2) W is applicable when mounting D-A9, D-M9, D-M9W and D-M9AL.
Lead wire entry Grommet [OA33(c): DINJ Grommet Grommet Grommet Response time 1.2 mS 1.2m$ 1 2 mS 1.2 mS Solid State Switch Type AUto switch model D-F59. 0-G59 D-F5P I D-GSP D-K39(C). D-J59. D-K59 D-J51 Wire type 3 W,re 3 Wire 2 Wire 2 Wire .. Output NPN PNP Application Relay, PLC Relay. PLC 24VDC Relay, AC A e~y.
+) Brown [Red] Main switch circuit OUT () Blue [Black] 12 2 Color Indication Solid State Switches/Direct Mount Type D-F9NW(V), D-F9PW(V), D-F9BW(V) Auto Switch Specifications Grommet D-F9W, D-F9WV (with indicator light ) D-F9NW In-line D-F9NWV D-F9PW D-F9PWV D-F9BW In-line D-F9BWV Auto switch part no.
Minimum Stroke for Auto Switch Mounting [mm] Auto switch model Number of auto switches 32 40 50 63 80 100 2 (Same surface) 50 D-M9l D-M9lW 1, 2 (Different surfaces) 10 n 10 + 40 (n 2) 2 (Same surface) 40 D-M9lV D-M9lWV 1, 2 (Different surfaces) 10 n 10 + 30 (n 2) 2 (Same surface) 55 50 D-M9lA 1, 2 (Different surfaces) 15 10 n 15 + 40 (n 2) 10 + 40 (n 2) 2 (Same surface) 40 D-M9lAV 1,
optionally selected points 2 2 LZm LZm Operationability Speed control 1 1 LC3F2 LC3F2 0 0 Xm Xm Air cylinder Electric actuator Price Shock-free Machine difference Machine difference D-m D-m Both end position accuracy Both end position accuracy 3 3 3 3 Speed Speed reproducibility reproducibility High speed operation Pushing applications Processby-process setting 2 2 2 2 E-MY E-MY Speed control
Note 2) M5: Suffix -4, M6: Suffix -1 Note 3) M5: Suffix -1, M6: Suffix -2 Adapter D P3200152-12 (M2.5 x 28) Philips screw ZF M2.5 x 12 Philips screw How to order (1) Valve unit (Supply valve: Air operated) (For replacement) Adapter D (2) Individual spacer R1 ZP M2.5 x 12 Philips screw Adapter D individual spacer R1 assembly Assembly no.
B A C Operating Range D B D-Z7/Z8, D-Y7W D-Y5, D-Y7 D-Y6, D-Y7V D-Y7WV D-Y7BAL Bore size (mm) A C 11.5 (10) 18.5 (17) 26.5 (25) 34 (32.5) 34 (32.5) 44 (42.5) D 0.5 (1) 3.5 (2) 0.5 (1) 3 (1.5) 5 (3.5) 5 (3.5) C 13 20 28 36 36 46 D C 5.5 12.5 20.5 28 28 38 Auto switch model Bore size (mm) 6 10 15 20 25 32 9 7 9 9 9 11 6 10 15 20 25 32 5.5 2.5 5.5 3 1 1 2 5 2 4.5 6.5 6.5 4.5 7.5 4.5 7 9 9 15.5