They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1) , and other safety regulations. *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems. IEC 60204-1: Safety of machinery -Electrical equipment of machines .

Green 1 URL http://www.smcworld.com Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 6 9 5. Apply a thickness gauge again and check that the Green turns on.

Metric size 4, 6 6, 8, 10 10, 12 Inch size 1/8, 1/16, 1/4 1/4, 3/8 3/8, 1/2 Orifice diameter 4.4 8 10 Flow characteristics Av x 10-6m2 12 33.6 52.8 VC Cv 0.5 1.4 2.2 Withstand pressure (MPa) 1 VDW Operating pressure (MPa) 0 to 0.5 Fluid temperature (C) 5 to 90 VQ Ambient temperature (C) 0 to 60 VX2 Weight (kg) 0.055 0.115 0.185 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San

Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1

Note 4) Assembly of a bracket and set nuts Standard Specifications AWM20 AWD20 AWM30 AWD30 AWM40 AWD40 Model Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Set pressure range 0.05 to 0.85 MPa Pressure gauge port size Note 1) 1/8 1/4 Ambient and fluid temperature Note 2) 5 to 60C (with no freezing) AWM20 to AWM40 0.3 m (95% filtered

Thread R(PT) Port B min. port size Weight (g) D2 L1 L2 L3 P A Q1 Q2 M1 M2 1 8 1 4 3 8 6 4 KM14-04-06-01S-3 13 14 17 18 13 10.4 38.2 16 9.9 17 68 71.5 73.5 19 26 39 4.5 KM14-04-06-02S-3 12.8 10.4 KM14-04-06-03S-3 64 65.5 67.5 1 8 1 4 3 8 8 4 KM14-04-08-01S-3 31 69.5 70.5 71 73.5 76.5 77.5 17 19 15.5 10.4 38.2 16 11.1 18.5 39 6 KM14-04-08-02S-3 15.2 10.4 KM14-04-08-03S-3 1 8 1 4 3 8 8 6 KM14

The M12 SPEEDCON connector connection method is explained below. (1)Align mark B on the metal bracket of the cable connector (plug/socket) with mark A. 7 10 8 SF Displays the system status. 1 9 BF Displays the communication status. (2)Align with mark C on the unit and insert the connector vertically. If they are not aligned, the connector cannot be connected correctly. Content No.

Metal piping attachment Indicator LED (OUT1) Indicator LED (OUT2) Lock ring Function selection mode PFM7 button (SET) Nominal thread size Required torque S Connector Piping port (OUT side) Rc (NPT)1/8 7 to 9 Nm Rc (NPT)1/4 12 to 14 Nm Thank you for purchasing an SMC PFM7 Series Digital Flow Switch.

They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1), and other safety regulations. *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems. IEC 60204-1: Safety of machinery -Electrical equipment of machines .

LEC-OM09402 PRODUCT NAME AC Servo Motor Driver (Parameter Configuration using Setup software (MR Configurator2TM)) MODEL / Series / Product Number LECS Series CONTENTS CONTENTS . 1 Introduction . 5 1.

Description Material y Stainless steel 1301-002 1301-1202 1301-2502 1301-902 6 Pilot valve Stainless steel/NBR 1301207#1 1301207#1 u 7 Element Bronze 1301-5B 1301-5B !

assembly Seal 6 Stainless steel, NBR 7 Stainless steel 8 Stainless steel 9 Stainless steel 10 SPC Option 11 Stainless steel 12 AL 13 NBR 14 15 CR 16 DIN terminal Cable 6 to 12 Hexagon width across flats 22 DIN terminal Conduit terminal 2 x Rc , , 4 1 8 3 2 1 (For only VXH2230-04, Rc ) 2 x M5 x 0.8 x 8 2 1 For Rc 1/4, 3/8 334

1*ua,+.i+u' 9 4 World Wide QS\E Support... North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc. (Cleveland) 2305 East Aurora Rd., Unit A-3 Twinsburg, OH 44087 Tel: (330) 963-2727 FAX: (330) 963-2730 SMC Pneumatics Inc.

ALF400 to 600 1 1 2 2 1 Metal case with a level gauge X208 ALF400 to 900 2 1 4 3 1 1 1 2 4 1 Line pressure (MPa) 2 1 Note 1) Tank pressure is removed when line pressure is stopped.

Metric size Inch size Stations Symbol 1 2 3 4 5 6 7 8 9 M Elbow Straight Elbow OUT side Mounting position Elbow Straight Elbow OUT side Mounting position IN side Straight 6 IN side Straight 1/4 1 station Fitting type Fitting type 2 stations 8 6 8 6 4 6 4 1/4 1/4 1/4 Symbol Symbol 5/16 5/16 5/32 5/32 3 stations 07 08 09 10 19 20 21 22 26 27 28 29 33 34 35 36 57 58 59 60 69 70 71 72 76

Series ACG How to Order ACG 30 A 03 G1 Option Symbol Description Applicable model Body size Nil 1 2 3 6 8 C J N R ACG20 to 40 Port size Symbol (8) 0.02 to 0.2 MPa setting ACG20 to 40 20 30 40 1/8 Metal bowl ACG20 to 40 3/8 Lubricator with drain cock ACG20 to 40 1/2 Nylon bowl ACG30, 40 Metal bowl with level gauge ACG20 With bowl guard Model combination ACG20 to 40 (9) Filter case with drain

Option (1) 6 7 8 9 24 Nil 1 2 3 4 5 Valve type None With flow rate adjustment With bypass High back pressure with flow rate adjustment High back pressure with bypass 0 1 2 N.C. N.O. Double acting Note) Refer to variations in the table below for valve type and option (1) combinations. Options (1) can not be combined each other.