10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
, Choice of 2 piping directions rear and bottom ported , Panel or bracket mounting , Resolution and MPa/kPa switching function , Analog current output, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DX, ISE40/50/60 1/4 (MISC.
, Choice of 2 piping directions rear and bottom ported , Panel or bracket mounting , Resolution and MPa/kPa switching function , Analog current output, SWITCH ASSEMBLY, INSTRUMENTATION, ISE40/50/60 PRESSURE SWITCH, DX, ISE40/50/60 1/4 (MISC.
LXF ELECTRIC SLIDE TABLE Low Profile Electric Slide Table; 5 Phase Stepping Motor; Stroke Length Options: 25, 50, 75, 100mm. LXP ELECTRIC ACTUATOR WITH GUIDES Low Profile Electric Actuator With Guides; 2 Phase / 5 Phase Stepping Motor; Stroke Length Options: 50, 75, 100, 125, 150, 175, 200mm.
ISA2 Note) 5 With LED light (24 VDC, Red) 50 20 to 50 l/min Note) 6 With LED light (24 VDC, Green) IS Note) LED light is available for 5, 6, 7, 8 (with terminal box for 24 VDC).
Solenoid Specifications 3 (R) 1 (P) 1 (R) 3 (P) Order Made P.2.1-15 13 24 SY1 A 13 24 SY1 Series Grommet (G), (H), L plug connector (L), M plug connector (M) Electrical entry Coil rated voltage (V) DC 24, 12, 6, 5, 3 AC 50/60Hz 100, 110, 200, 220 Allowable voltage 10 to +10% Power consumption (W) (1) DC 0.75W (With light: 0.8W) 0.5W (With light: 0.55W) 0.9 (With light: 1.0) 100V 110V [115V
SealKir 25, 30, 35, 40. 45, 50, 75, 100 25 30,35,4A, 45,50.75, tOD 25, 30, 35.40, 45, 50, 75, 100 .Ho{ to make interrediaie slroke rtrmediale stroke berwen 50-l0o (5s,60,65 ...) are obtained throlgh the use ol spaceB (5. 10, 1s,20mm) (Example) CDQBPSo-55 oMr S[4C would install a 20mrn width spacer in rire cDQ2Bp 50 750M. ll lool brackel is required, order 2 pcs/cylindef.
AC DC Auto switch model Lead wire length (m) 0.5 (Nil) Load voltage Indicator light Wiring (Output) Special function Type Electrical entry Pre-wire connector Applicable load 3 (L) 5 (Z) Perpendicular In-line IC circuit 3-wire A96V A96 5 V Reed switch Solid state switch Grommet (NPN equivalent) Yes Yes 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV
When used in a balance control circuit, there are instances in which the check valve cannot release, even though the pilot pressure is 50% of the operating pressure. In these cases, the pilot pressure should be the same as the operating pressure. 5.
Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O.
Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O.
Nil S n Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type 2 pcs. 1 pc. n pcs.
Compact Cylinder with Solenoid Valve/ Guide Rod Type 32, 40, 50, 63 Series CVQM How to Order CVQM 32 30 M9BW 5 M Port thread type 32 40 M5 x 0.8 Bore size 32 40 50 63 Nil 32 mm 40 mm 50 mm 63 mm Rc G NPT 50 63 F N Piping Nil P Standard Axial Cylinder stroke (mm) Refer to the next page for Standard Stroke and Intermediate Stroke.
Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications
type y Stroke [mm] Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 50 50 to to 1200 1200 Nil Without option B With lock Nil Without cable S Standard cable R Robotic cable (Flexible cable) o Actuator cable length [m] !
x 1.5 M18 x 1.5 300 800 1250 3100 0.5 0.5 0.75 1 5 Semi-standard/Thread nominal size 0.5 0.5 0.5 0.75 0.75 0.75 1 1 300 800 800 1250 1250 1250 3100 3100 JC20-8-100 JC25-10-150 JC32-10-100 JC40-12-125 JC40-12-150 JC40-12-175 JC50-16-150 JC63-16-200 M8 x 1 M10 x 1.5 M10 x 1 M12 x 1.25 M12 x 1.5 M12 x 1.75 M16 x 1.5 M16 x 2 20 25 32 32/40 40 32/40 50 50/63 5 How to Order 14-150 JC 40 Thread
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?