.+100 Name Range of values Setpoint P2 21999 P1+H299.9 P1+H299.9 750 Set the value for energy saving function and vacuum/release confirmation. The value of P2, P1 represents negative pressure, the value of P3 represents positive pressure. Enter a value that is 10 times the pressure value [kPa]. ex) P2 = -65 [kPa] -> P2 sets 650 Refer to Section 4.1.7.
Cable Type A specification Item Specification Impedance 135 to 165 Capacity 30 pF/m or less Loop resistance 110 /km Wire diameter 0.64 mm or more Core cross-section 0.34 mm2 or more Lower-level bus Item Specification Number of branches for input/output 4 branches (16 points/branch) for input 4 branches (16 points/branch) for output Communication method Protocol: Dedicated for SMC Speed: 750
1.5 M8 x 1.25 M18 x 1.5 12 14 15 11.5 M10 x 1.5 M22 x 1.5 M10 x 1.5 M26 x 1.5 17 With Rod Boot Note) ZZ indicates dimensions for double side rod boot. l h ZZ Note) Bore size (mm) e f 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 750
Double acting, Single rod Fluid Air Proof pressure 145 psi (1.0 MPa) Maximum operating pressure 102 psi (0.7 MPa) Minimum operating pressure 7 psi (0.05 MPa) Without auto switch: 14 to 158F (10 to 70C) (No freezing) With auto switch: 14 to 140F (10 to 60C) (No freezing) Ambient and fluid temperature Lubrication Not required (Non-lube) +1.4 0 mm Stroke length tolerance Piston speed 50 to 750
5.50 1/2 NPT 4.50 .94 .95 2.88 2.75 2.500 1.38 7.13 1.375 1-14 1.63 2.000 1.530 1.000 6.50 3/4 NPT 5.00 1.31 1.32 3.13 3.25 3.000 1.63 8.13 10 MP2 Double detatchable head side clevis style (D) XD + Stroke A UB P + Stroke 2-EE MR MAX KK MM B CD (PIN) TH LR CB E WF LF + Stroke F Bore Size (in) MM KK A B CB CD E EE F LF+ LR MR P+ TH UB WF XD+ 500 (5") 1.000 3/4-16 1.13 1.500 1.280 .750 5.50
OPTIONS AND PERIPHERAL EQUIPMENT Table 11.2 Servo motor leakage current example (lgm) Servo motor power [W] Leakage current [mA] 50 to 750 0.1 Table 11.3 Driver leakage current example (Iga) Driver capacity [W] Leakage current [mA] 100 to 400 0.1 750 0.15 Table 11.4 Earth-leakage current breaker selection example Driver Rated sensitivity current of earthleakage current breaker [mA] LECSS2
) Pr = a (PD) + b = 0.016 750 + 0 = 12.0 [L/min] (2) Conversion from the flow measurement value to the process data (For PF3W7 series, unit L/min, flow range 16 L and Pr = 0.8 [L/min]) (PD) = (Pr b) / a = [8.0 0] / 0.016 = 500 (1) Conversion from the process data to the temperature measurement value (For PF3W7 series, unit oC, common flow range and PD = 50) Pr = a (PD) + b = 0.1 -50 +
) Pr = a (PD) + b = 0.016 750 + 0 = 12.0 [L/min] (2) Conversion from the flow measurement value to the process data (For PF3W7 series, unit L/min, flow range 16 L and Pr = 0.8 [L/min]) (PD) = (Pr b) / a = [8.0 0] / 0.016 = 500 (1) Conversion from the process data to the temperature measurement value (For PF3W7 series, unit oC, common flow range and PD = 50) Pr = a (PD) + b = 0.1 -50 +
Standard stroke (mm) Max. stroke without switch (mm) Max. stroke with switch (mm) Bore size (mm) Symbol Specifications 300 300 6 50, 100, 150, 200 -X116 -X160 -X322 -X1468 Hydro specifications 500 500 10 50, 100, 150, 200, 250, 300 High speed specifications 50, 100, 150, 200, 250, 300 350, 400, 450, 500 Outside of cylinder tube with hard chrome plating 15 1000 750 Interchangeable specification
Connected A B C D E F G H I J IDF190D JIS10KFF 80A(3B) flange 750 1510 1320 375 480 600 700 800 355 427 IDF240D JIS10KFF 100A(4B) flange 770 1550 1640 385 703 730 700 800 355 467 Auto drain is included in the package.
www.stevenengineering.com I 6.9 HANDLE OPERATED VACUUM REGULATOR SERIES T203 HANDLE OPERATED VACUUM REGULATOR SERIES T203 A v a c u u m r e g u l a t o r, i n s t a l l e d a f t e r a v a c u u m pump, which regulates vacuum at any level T E C H N I C A L SPECIFICATIONS Setting vacuum 10~750 Torr (mmHg) Sensitivity 1 Torr (mmHg) Repeatability 3 Torr (mmHg) Max. flow rate 120 Nl/min Weight
500 kbps Thick cable 500 m or less 250 m or less 100 m or less Max. length of Network Thin cable 100m or less 156 m or less 78 m or less 39 m or less Total extended cable length : Max. extended cable length is 6 m Lower-level bus Number of branches for input/output 4 branches for input, 4 branches for output Communication type Communication protocol: dedicated for SMC Communication speed: 750
1,000 L5 [mm] L5 [mm] L5 [mm] 750 1,000 1,000 500 500 500 250 m Mey 00 1 2 3 4 5 00 0.1 0.2 0.3 0.4 0.5 00 0.5 1.0 1.5 2.0 L5 Work load m [kg] Work load m [kg] Work load m [kg] 28 Electric Slide Table/High Rigidity Type Series LESH Model Selection 2 Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Selection Procedure For the compact type LES series, refer to page 5.
700 30 700 80 700 60 700 6 80 800 40 800 100 800 80 800 7 100 900 50 900 200 900 100 900 8 150 1000 75 1000 300 1000 200 1000 9 200 1200 100 1200 400 1200 250 1200 10 250 1400 125 1400 500 1400 300 1400 11 300 1600 150 1600 600 1600 400 1600 12 350 1800 175 1800 700 1800 500 1800 13 400 2000 200 2000 800 2000 540 2000 14 450 2500 225 2500 900 2500 600 2500 15 700 3000 360 3000 1100 3000 750
900st 1.5 800st 700st 1 600st st: Stroke (mm) 400st 500st 0.5 100st 200st 300st 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGGM 100Stroke 4 (Slide bearing type) 3.5 3 Deflection Y (mm) 1300st 2.5 1200st 1100st 2 1000st 1.5 900st 800st 1 600st 700st st: Stroke (mm) 500st 0.5 400st 100st 200st 300st 0 0 100 50 150 200 250 300 350 400 450 500 550 600 650 700 750
If vibration is applied, malfunction or setting errors may result. 750
4846 8320 75 1117 1499 2101 3299 5661 9530 100 1332 1774 2471 3844 6476 10740 Unit: g CHKDL/Foot type Bore size (mm) Standard stroke (mm) 5 10 15 20 25 30 35 40 45 50 75 100 20 25 32 40 50 63 80 100 1505 2195 3310 5475 9150 14930 560 690 1060 1610 2515 4310 7410 12375 465 570 880 1375 2200 3845 6555 11355 490 600 925 1435 2280 3960 6725 11610 580 720 1100 1670 2595 4425 7580 12630 605 750
PF2W504T--1 PF2W520T--1 PF2W540T--1 PF2W504T--2 PF2W520T--2 PF2W540T--2 Pin description 4 4 0.5 0.5 1 DC(+) 16 16 2 2 2 NC/Analog output 40 40 5 5 3 DC() 4 OUT 318 B Series PF2A/PF2W For Air/Water Digital Flow Switch Description Integrated Display Type PF2A710, 750, 711, 721, 751 PF2W704(T), 720(T), 740(T), 711 Remote Type/Monitor Unit PF2A300, 301, 310, 311 PF2W300, 301, 330, 331 Position
point 32) Station type Remote device station Communication speed 156 Kbps 625 Kbps 2.5 Mbps 5 Mbps 10 Mbps Cable length between stations 20 cm and over Maximum extended cable length 1200 m 900 m 400 m 160 m 100 m Lower level bus Number of branches for input/output 4 branches for input, 4 branches for output Communication type Communication protocol: dedicated for SMC Communication speed: 750
Lower-level bus Number of branches for input/output 4 branches for input, 4 branches for output Communication type Communication protocol: dedicated for SMC Communication speed: 750 kbps Current for input branch Max .1 A per branch Current for output branch Max. 1.5 A per branch Branch cable length Within 20 m (See diagram below for details.) : Maximum value in total of current consumption