SMC Corporation of America
Elite Part Number Search
Search Results "CLSL200TN-2000-D"

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Residual voltage 1 V or less (with load current of 80 mA) Response time 2.5 ms (Response time selections with anti-chattering function: 20 ms, 160 ms, 640 ms, 1000 ms, 2000 ms) ZSP Short circuit protection With short circuit protection 0.5%F.S.

(Valve in the initial stage) Vibration resistance: No malfunction from test with 45 to 2000 Hz one sweep, to axis and right angle direction of main valve, each one time when pilot signal ON and OFF .

Standard Stroke Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) D16 100, 200, 300, 400, 500, 600, 700, 800, 900 1000, 1200, 1400, 1600, 1800, 2000 3000 -X 25, 40 5000 Strokes are manufacturable in 1 mm increments, up to the maximum stroke. When exceeding a 2000 mm stroke, specify -XB11 at the end of the model number.

However, when exceeding 2000 mm stoke, add "-XB11" to the end of the model number. Refer to "Made to Order" on page 40. 80 to 1500 mm/s Refer to "External Shock Absorber Selection" on pages 10 and 11. When the RB series is used, operate at a piston speed that will not exceed the absorption capacity of the air cushion and stroke adjustment unit.

stroke (mm) Maximum available stroke (mm) 300 50, 100, 150, 200 6 500 50, 100, 150, 200, 250, 300 10 15 20 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 1000 1500 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 3000 32 3000 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000

Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted

Manifold Regulator ARM1000/2000 Series ARJ Standard Specifications Fluid Proof pressure Maximum operating pressure Air 1.2 MPa 0.8 MPa Standard: 0.05 to 0.7 MPa 0.2 MPa setting 0.05 to 0.2 MPa 5 to 60C (No freezing) Air 0.02 MPa Relieving type AR425 to 935 4 connection methods ARX Regulating pressure range AMR Ambient and fluid temperature Fluid Cracking pressure (Valve) Construction ARM

" # $ % $& ' ($ % $& ) Input unit GW unit SI unit VQC1000 2000 4000 SI unit Input unit SV1000/2000/3000/4000 How to Order GW Unit GW Unit DN1 EX500 G Communication protocol DN1 PR1A MJ1 EN1 DeviceNet PROFIBUS DP CC-Link EtherNet/IP 1680

Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted

Specialty Regulator s NARM Ser ies Regulator for Manifold NARM1000, 2000 Standard Specifications 4 Ways of Connection Fluid Air Proof pressure psig (MPa) 175 (1.2) Max. operating pressure psig (MPa) 120 (0.8) Set pressure range psig (MPa) 7~100 (0.05 to 0.7) 23~140F (5 to 60C) (No freezing) Ambient and fluid temperature Fluid Air Cracking pressure (Valve) psig (MPa) 3 (0.02) Construction

Note 2) Applicable up to 2000 mL/min by using a solenoid valve with a large Cv value (Cv value of 0.5 or more). Note 3) With low operating cycles, even a valve with a small Cv value can be operated. 584

IR1000/2000/3000 Series How to Order IR 2 0 0 02 0 Precision regulator Thread type Body size Nil N Note 2) Rc NPT Suffix 1 1 2 3 IR1000 series IR2000 series IR3000 series Nil G F For high temp. environments (5 to 100C) For low temp. environments (30 to 60C) T Note 4) Semi-standard Type of setting L Note 5), 6) 0 1 Note 1) Basic type (Knob) Air operated type Suffix 2 Set pressure range

Gauge port 2) (Inlete, Outletr) Porting Configuration Pressure gauge Code r psig/bar unit MPa unit r e No pressure gauge 0 6 10 20 40 60 Q w q w q 600 psig/bar 3) 4.1 MPa 7 MPa 14 MPa 28 MPa 41 MPa 70 MPa qIN wOUT eGauge port (Inlet) rGauge port (Outlet) Connections (Inletq, Outletw) 1000 psig/bar 3) Ports Code 2000 psig/bar 3) Connections 4P V 4PN e 4P 4PN 4000 psig/bar 3) 4 4B NPT 1/4 inch

4000 6000 0 0 0 200 400 600 800 1000 1000 2000 Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) VH600 Effective area S = 194 mm2 Supply pressure MPa Supply pressure MPa 0.7 Valve output pressure (MPa) 0.7 0.6 0.6 0.5 0.5 0.4 0.4 0.2 0.3 0.3 0.2 0.1 0.1 0 5 10 15 Flow rate (m3/min (ANR)) 5-8-8

Specications Clamping Force W-R1-S2Type Type 1 Type 3 Mass of transferred object 1000 kg or less 3000 kg or less 5000 Possible amount of positional correction 50 mm or less 4000 Clamping force 4430 N 4070 N Clamping force [N] Operating time 1.0 s or more 0.8 s or more 3000 Cylinder operation stroke 83.5 mm 140 mm Bore size 100 mm 2000 Cylinder proof pressure 1 MPa Max. operating pressure

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.

EX260 compact serial interface unit is applicable to the SY3000/5000, SV1000/2000/3000, VQC1000/2000/4000 and S0700 series valves. The EX260 module is an output only SI unit that can be connected to any manifold designed for the EX250 series. Available protocols are PROFIBUS DP, DeviceNet and EtherCAT., SI UNIT, VALVE, EX300 SERIAL INTERFACE UNIT, 22, EX300, .44092 lb

Serial interface unit EX500 is capable of controlling up to 64 solenoids, and is compatible with SV1000/2000/3000/4000, VQC1000/2000/4000 valves. The EX500 makes it possible to connect up to 4 valve manifolds with up to 16 solenoids each.