Val 1000 -52No.EX-OMN0029CN-D (2) No.
Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-M9, D-M9V (With indicator light) 2-wire load current is reduced (2.5 to 40 mA) Lead-free UL certified (style2844) lead cable is used. D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B
of switch Indicator light 2 OUT() Blue [Black] 20 2.7 2.8 4.6 3.8 3.1 6.2 4 Most sensitive position 6 10 Solid State Switches: Direct Mounting Type D-F9NW(V), D-F9PW(V), D-F9BW(V) Specifications Grommet D-F9W, D-F9WV (with indicator light ) D-F9NW In-line D-F9NWV Perpendicular D-F9PW D-F9PWV D-F9BW In-line D-F9BWV Auto switch part no.
57.2 45.2 9 18.1 Q2 Q2 Round type P D 4 to 12 2 x N Q1 2 x O 3 x Applicable tubing *1: D is maximum diameter.
(mm) 2 Effective area (mm2) Weight (g) D L Q Model D KJT02-00 6 10 4.9 8.8 0.9 1.7 Q Q 3.2 5.2 Q M Q L D D M M L L Male branch tee: KJY T H A Applicable tubing O.D.
AF-OMX0054-B PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AFD20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFD30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFD40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.
B A A B 1 Chromic acid (25%, 70C) B D D A A B 2 Boric acid Inorganic salt B D A A B A 3 Sulphuric acid (30%, Room temperature) D D A A B A 4 Phosphoric acid (50%, Room temperature) D A A B B A 5 Ammonium hydroxide B A A B B D 6 Sodium hydroxide (30%, Room temperature) Inorganic alkali A D C D A A 7 Calcium hydroxide A D A A C A 8 Magnesium hydroxide A B A A B A 9 Acetylene A A A A A A 10
(Same surface) Hs 22 B A D-A93 24.5 10.5 16.5 50 50 50 D-M9B D-M9BW D-B54 50 50 75 Auto Switch Mounting Position and Its Height Unit: mm 8.5 Auto switch set value and its height 63 7.5 30.5 47 11.5 34.5 47 2 25 50.5 Auto switch Symbol 40 11 23.5 34.5 15 27.5 34.5 5.5 18 38 50 7.5 30.5 40 11.5 34.5 40 2 25 43.5 A B Hs A B Hs A B Hs D-B54 D-A93 Hs B A 33 D-M9B D-M9BW D-B54 12 Note 1) The
NPT AD47N-8(Z)-A Appearance and part No. -17- D Note 1) D Note 1) Option symbol 2 Semi-standard symbol 6 Semi-standard: 2 Semi-standard: Piping port thread ty pe (4) Part No. Piping port thread ty pe (4) Part No. Rc Rc AD48-2-A AD48-D G G NPT AD48N-2(Z)-A NPT AD48N(-Z)-D Appearance and part No.
Moreover, in applications where impact occurs from a stopper, etc., the mounting bolts should be inserted to a depth of 2 d or more (1.5 d or more for MGPS). Series MGP Series MGPS (d = Thread O.D.) (d = Thread O.D.) Piping 1.5 d or more 2 d or more Caution Depending on the operating conditions, piping port positions can be changed by using a plug. 1.
R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult P/A Customer Service for larger sizes.
R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult SMC Customer Service for larger sizes.
50 63 D-F7WV D-F9WV D-F7BAVL D-F7V D-J79C D-M9V Number of auto switches D-A7, A7H D-A73C D-A80, A80H D-A80C 11 10 12 12 D-A79W D-A9, A9V 13 14 14 16 CL 1 pc. 2 pcs. 20 20 20 20 20 20 20 20 9.5 9.5 9.5 11.5 D-F7, F7V D-J79, J79C D-F7W, F7WV D-J79W D-F7BAL, F7BAVL D-F7NTL, F79F CL1 D-F7W D-J79W D-F7BAL D-F79F D-F9BAL 6 6 6 6.5 MLGC Number of auto switches D-A9 D-M9 D-A79W CNG D-M9, M9V 3.5
Note) D1: Max. diameter 45 Male Elbow: KRK D A M Effective area (mm 2) Weight (g) H (width across flats) Applicable tubing O.D.
M O D E N o r m a l Function
A B C D A B C D Bore size (mm) Port aperture A 12 (1) (1) (1) CUJ 16 (2) (2) (2) CU B D 20 (2) (2) (2) View from piston rod end 25 CQS (2) (2) (2) 32 C (2) CQM 40 (2) CQ2 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (2) RQ Operating Range Auto Switch Mounting
Type Model Features Electrical entry (Fetching direction) D-A73 D-A80 D-A73H, A76H D-A80H D-F7NV, F7PV, F7BV D-F7NWV, F7BWV D-F7BAVL D-F79, F7P, J79 D-F79W, F7PW, J79W D-F7BAL D-F7NTL Without indicator light Without indicator light Diagnostic indication (2-color indication) Water resistance (2-color indication) Diagnostic indication (2-color indication) Water resistance (2-color indication