ZXP 7 A 21 20 X1 Vacuum Gripper 1 Suction Cup Part Numbers and Weight 2) Cup mounting flange shape 1) Body size 4) Cup series 5) Cup diameter 6) Cup form 7) Cup material 8) Attachment *3 3 ) Compatible robot manufacturer Symbol Cup series Symbol Cup Symbol Robot manufacturer Symbol Size Symbol Shape Symbol Attachment Symbol Cup form Symbol Material diameter 7 75 A 21 FANUC:CRX-10iA,10iA/
ZXP 7 A 01 20 X1 Vacuum Gripper 1 Suction Cup Part Numbers and Weight 2) Cup mounting flange shape 1) Body size 4) Cup series 5) Cup diameter 6) Cup form 7) Cup material 8) Attachment *3 3 ) Compatible robot manufacturer Symbol Flange Shape Symbol Robot manufacturer Symbol Size Symbol Cup Series Symbol Cup diameter Symbol Attachment Symbol Cup form Symbol Material 7 75 A 01 UR: 3(e), 5(e
Lifting force = Theoretical lifting force / t Theoretical lifting force (Theoretical lifting force = P x S x 0.1) Cup diameter (8 to 32) [N] Cup diameter [mm] 8 10 13 16 20 25 32 S: Cup area [cm2] 0.50 0.79 1.33 2.01 3.14 4.91 8.04 -85 4.2 6.6 11 17 26 41 68 -80 4.0 6.2 10 16 25 39 64 -75 3.7 5.8 10 15 23 36 60 -70 3.5 5.5 9.3 14 22 34 56 Vacuum -65 3.2 5.1 8.6 13 20 31 52 pressure -60 3.0
INLET AIR OUTLET PORT SIZE PORT SIZE A B G Q E D WITH LAMP SWITCH DRAFT AIR OUTLET THERMOMETER EVAPORATION BALL VALVE BLOCK TRMINAL AUTO DRAIN F C VENTILATION VENTILATION DRAIN TUBE (O.D.10, LENGTH:1m) J K L P H N M ELECTRICAL ENTRY 413 (WIRE 9 ` 11) [OPPOSITION] measure mm Model Port size A B C D E F G H J K L M N P Q R IDF55E 800 (868) IDF75E 900 (968) 36 50 526 (250) 5195 13 500 75
5.7 8.4 11.0 m 60Hz 4.3 6.1 9.8 12.4 3/min (ANR)1 MPa 0.7 35 40 32 10 550 MPa 0.151.0 24085% (4) V AC200(50Hz) / AC200,220(60Hz) (2) A 4.3 / 4.7 3.3 / 3.5 4.3 / 4.7 3.3 / 3.5 6.0/6.6 7.2/8.0 (2) W 810 / 940 850 / 1070 810 / 940 850 / 1070 1450/1890 2000/2500 (3) A 10 15 R407C (HFC) g 42010 47010 73010 83010 55010 72010 R1 R11/2 R2 mm 10 1 2 kg 54 62 100 116 kW 22 37 55 75
) AC200/220V10% 50Hz/60Hz ( 4) AC230V (50Hz) 4.3 6.9 10.7 AC200V (2) A (50/60Hz) 4.2/4.8 6.7/7.3 8.2/9.3 AC230V (50Hz) 960 1570 2300 AC200V (2) (50/60Hz) 1100/1450 1570/2050 2000/2850 AC230V (50Hz) 10 20 AC200V (3) A (50/60Hz) 10 15 R407C (HFC) AC230V (50Hz) 45010 76010 55010 74510 g AC200V (50/60Hz) 47010 83010 55010 74510 R1 R11/2 R2 mm 10 1 2 kg 90 130 160 166 kW 22 37 55 75
Note 2: Air flow capacity converted by the compressor intake condition [32C, atmospheric pressure, and 75% relative humidity]. Note 3: Do not use this product with continuous voltage fluctuations. Note 4: These values are reference values under rated conditions and are not guaranteed. Do not use these values for the thermal set values, etc.
140 230 -40 -60 pressure dew point oC *Note2 Inlet air flow rate L/min(ANR) Outlet air flow rate L/min(ANR) 75 110 170 240 300 50 100 150 Standard Performance conditions 18 25 54 68 100 25 40 80 Purge air flow rate L/min(ANR) *Note3 Inlet air pressure MPa 0.7 25 25 Inlet air temperature oC Inlet air saturation temperature oC 25 Dew point indicator purge air flow rate Ambient temperature
140 230 Outlet air atmospheric -40 -60 *Note2 pressure dew point oC Inlet air flow rate L/min(ANR) Outlet air flow rate L/min(ANR) 75 110 170 240 300 50 100 150 Standard Performance conditions Purge air flow rate L/min(ANR) 18 25 54 68 100 25 40 80 *Note3 Inlet air pressure MPa 0.7 25 25 Inlet air temperature oC Inlet air saturation temperature oC 25 Dew point indicator purge air flow rate
The relative humidity of the ambient environment should be 75 RH% or less. If the ambient humidity is higher, condensation prevention may not occur. If the ambient temperature exceeds the product specifications, the outside diameter will become swollen due to the absorption of moisture.
pe pressure gauge (Semi-standard: Z) Round ty pe pressure gauge (With color zone) Standard specifications Round type pressure gauge P1 P2 A B C D E F G J K J J J AWM20-D 1/8, 1/4 1/8 40 100.6 71.8 21 M281 45 21 5 37.5 57.5 37.5 58.5 37.5 58.5 AWM30-D 1/4, 3/8 1/8 53 115.4 86.5 26.5 30 M381.5 50 26.5 3.5 37.5 63 37.5 64 37.5 64 AWM40-D 1/4, 3/8, 1/2 1/8 70 147.1 91.5 35.5 38.4 M421.5 75
pe pressure gauge (Semi-standard: Z) Round ty pe pressure gauge (With color zone) Standard specifications Round type pressure gauge P1 P2 A B C D E F G J K J J J AWD20-D 1/8, 1/4 1/8 40 100.6 71.8 21 M281 45 21 5 37.5 57.5 37.5 58.5 37.5 58.5 AWD30-D 1/4, 3/8 1/8 53 115.4 86.5 26.5 30 M381.5 50 26.5 3.5 37.5 63 37.5 64 37.5 64 AWD40-D 1/4, 3/8, 1/2 1/8 70 147.1 91.5 35.5 38.4 M421.5 75
No.PS-OMU0002CN-D // ZSE20A(F) ISE20A 2 8 10 11 15 15 17 19 [] 22 23 3 24 26 28 28 28 F0 30 F1 OUT1 31 F2 OUT2 34 F3 36 F4 37 F5 FUNC 39 F6 41 F10 42 F11 48 F80 49 F81 50 F82 52 F90 53 F96 55 F97 56 F98 58 F99 60 61 65 65 66 75 75 78 -1No.PS-OMU0002CN-D 1 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO
Specifications 75 Dimensions 77 -1No.PS-OMX1005 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
.=1.1000.01=0.011[MPa]) R.D. 1.000[MPa]5R.D.1.000[MPa]50.05[MPa] 0.800[MPa]5R.D.0.800[MPa]50.04[MPa] ON/OFF () (34 ) ON OFF 34 75 75 ON OFF Hysteresis / () () 25[]ON-OFF () -11No.PS-OMU0005CN-C NPN () () ()()( ) () ON ON 0 (1k1MA/D 5V A/D 5(V)1(M)/(1(k)+1(M)) 4.995(V)0.005V ) 34 ON-OFF ON ( )(P1L~P1H) ON (34 ) () "digit" () 0 -12No.PS-OMU0005CN-C () SI ON/OFF ON-OFF
Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, 1.07781 lb
Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .77161 lb
Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .62194 lb
Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, D7, ISE70/75 1/4 EURO VERSION, .62194 lb