SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2KL10-30RZ-B"

side parallelism to A side Non-rotating accuracy 0.005 B side traveling parallelism to A side 0.01 C side perpendicularity to A side Radial clearance C B 0.05 M dimension tolerance Radial clearance (m) 0 Note) 0 Note) M Non-rotating table accuracy (deg) Note) In theory, radial clearance and non-rotating table accuracy are zero by the preloaded specification.

B W 7.5 (5) (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V Bore size (mm) A A W B W B A W B 6 12.5 3.5 (6) 16.5 7.5 2.5 16.5 5.5 2.5 10 11.0 2.0 (0.5) 3.5 15.0 2.0 7.5 15.0 0 7.5 16 18.0 2.0 (0.5) 4.0 22.0 2.0 8.0 22.0 0 8.0 20 26.0 4.5 (2) 6.5 30.0 0.5 10.5 30.0 2.5 10.5 Note 1) Negative figures in the table W indicate an auto switch is mounted inward from the edge of the cylinder body.

How to determine the auto switch installation position MHZ2 Step 2) Insert auto switch into the switch installation groove from direction B. "Set up as directed with power connected under no pressure or low pressure." A B MHZJ2 MHQ Step 3) Slide the auto switch in the direction of the arrow until the light illuminates.

Y 0 16 IN313-DN1-B, IN313-PR1, IN313-AB1/AB2 Three major protocols are available: DeviceNetTM (IN313-DN1-B), Profibus-DP (IN313-PR1), Allen Bradley RIO (IN313-AB1, & IN313-AB2) Controls up to 16 (32 in case of IN313-AB2), single solenoid valves. (A combination of single and double solenoid valves as long as the maximum number of solenoids does not exceed 16 (32 for IN313-AB2.)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 V Body size Port size Rc Option Symbol P/A port R port B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) 00 M5 00 M5 01 00 01 02 00 02 03 04 Symbol Mounting Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Base mounted 1 8 1 4

Note Bracket B and the bracket assembly make up one set.

(Example) Body class 3 A side: 10 x 8 B side: 8 x 6 Order as shown below. A SMC LVN30 S 10 08 B Different dia. tubing size (B side) Applicable tubing size (A side) 17-5-132 2 Series LVN High Purity Fluoropolymer Needle Valve Standard Specifications Model LVN20 LVN30 LVN40 Tubing O.D.

Interface regulator SMC 1 P 5 3 R2 R1 PE How to Order Applicable interface regulator model Reduced pressure port Solenoid valve model ARBQ4000-00-A-1 A VQ40 (plug-in type) ARBQ4000-00-B-1 B ARBQ4000-00-P-1 P ARBQ4000-00-A-5 A VQ45 (plug lead type) ARBQ4000-00-B-5 B ARBQ4000-00-P-5 P Circuit Diagrams Reduced pressure port: A Reduced pressure port: B Reduced pressure port: P SMC Pneumatics,

A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

R802. 90A D-R731, R732 D-90 l B u e D-93A I I !

4 2 5 A 10 x 8 3/4" x 5/8" 5 1 5 B 19 x 16 1/2" x 3/8" 5 2 6 A 12 x 10 1" x 7/8" SMC 6 1 6 B 25 x 22 3/4" x 5/8" 6 2 19 x 16 : Basic size : With reducer Note) Please select an isometric fitting with the same size as the fitting at the flow sensor.

Description No. 2 Common IN Individual IN Common IN Individual IN Bonnet Polyacetal Regulator NARM2500-A-N02 NARM2500-B-N02 NARM3000-A-N03 NARM3000-B-N03 9 Regulator 1 Component Parts 10 End plate R 1 No.

For driving air operated valves for fluid control N.C N.O N.C N.C Air operated style fluid control valve Vacuum valve Vacuum pad A, B 1(P) A, B 1(P) A, B 1(P) A, B 3(P) 3(R) 3(R) 3(R) 1(R) Vacuum releasing air Atmospheric pressure or micro pressure The characteristic values shown in the catalog are representative values, not warranting the performance. 4-3-1 Series SY100 Precautions Be sure

Barb cassette creeps into the direction D and the tube will be clamped at the B clamp portion (5) consisting of barb (3) and case.

Operating Pressure Max. operating pressure (MPa) Group Model 20oC 100oC 200oC 260oC 2.4 Max. operating pressure (MPa) A B TLM0201 TLM0425 TLM0302 TLM0604 TLM0403 TLM0806 TLM1075 TLM1209 TLM1008 TLM1613 TLM1210 TLM1916 TLM2522 2.3 1.7 1.1 0.9 0.55 0.45 0.3 0.23 2.2 A 2.0 1.8 C 1.5 0.7 0.35 0.2 B 1.6 1.4 C 1.2 D 1 0.5 0.25 0.15 1.0 0.8 0.6 E 0.7 0.35 0.17 0.11 0.4 0.2 F 0.6 0.3 0.15 0.1 0.0

There are two types of alarm reset: alarm reset manually (a) and an alarm reset externally (b) by an external signal.

3 EA EA y A A P P r q B EB B !4 EB !7 !1 !2 t Component Parts Aluminum alloy NBR Note No. !0 Description Material No. PBT ADC Material Note q Description Black zinc chromated Metallic plated Pilot body Body Piston guide B Valve Metallic plated !1 !2 w e Return spring Cushion Cushion Valve spring Return spring Piston B Head cover r Stainless steel Spool/sleeve Stainless steel ZDC !

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) W 4 A 15.5 W 5.5 A 11.5 12 16 20 25 0.5 4.5 0 4.5 16 4 6 12 3.5 1 20 7.5 2.5 16 5.5 -1 21 9.5 0.5 17 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.

Stroke range Part no.: CLQB40-47D-B 3 mm spacer is installed in standard cylinder CLQB40-50D-B. B dimension is 79.5 mm. Example Note) 40 to 100 bumper spacers with intermediate strokes can be manufactured in 5 mm increments from 55 to 95 mm. D-X Individual -X 817

/N.C. 5 6 24 VDC 12 VDC (B) 2 (A) 4 A SOL.b SOL.a 3 (EB) 5 (EA) 1 (P) Pilot type Nil R Internal pilot External pilot 4 position dual 3 port valve: N.O./N.O. (B) 2 (A) 4 *External pilot specifications is not available for 4 position dual 3 port valves. B SOL.b SOL.a 3 (EB) 5 (EA) 1 (P) 4 position dual 3 port valve: N.C./N.O.