Actuation: Normally Closed, Coil Specification: T [w/Power Saving Circuit, (Continuous Duty Type)], Number of Solenoids: S [1pc. (Single Solenoid)], Voltage: 24 VDC, Common Specification: Negative Common, Connector Entry: MN [Individual Wiring, w/o Lead Wire (w/Connector, Socket)], 2A/2B Fitting Port Size: ΓΈ1/8" One-touch Fitting, Straight Fitting, Inch Size
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.05 to 5 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.01 to 1 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 0.05 to 5 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/8, Output Specification: Out 1: IO-Link or NPN/PNP, Lead Wire: -, Unit Specification: -, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -