sResponse timeHysteresisPower supply voltageResistancePF2A711Air, Nitrogen5 to 105 l/min5 to 105 l/min10 to 100 l/min1 l/min1 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2A711Air, Nitrogen5 to 105 l/min5 to 105 l/min10 to 100 l/min1 l/min1 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2A721Air, Nitrogen10 to 210 l/min10 to 210 l/min20 to 200 l/min2 l/min2 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2A721Air, Nitrogen10 to 210 l/min10 to 210 l/min20 to 200 l/min2 l/min2 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2A721Air, Nitrogen10 to 210 l/min10 to 210 l/min20 to 200 l/min2 l/min2 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2A751Air, Nitrogen25 to 525 l/min25 to 525 l/min50 to 500 l/min5 l/min5 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)170 mA or less290 g1/2Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2W704Water0.35 to 4.5 l/min0.35 to 4.5 l/min0.5 to 4 l/min0.05 l/min0.05 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less460 g3/8Karman vortex3-digit, 7-segment LEDReal-time flow rateAccumulated flow0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
sResponse timeHysteresisPower supply voltageResistancePF2W720Water1.7 to 17.0 l/min1.7 to 17.0 l/min2 to 16 l/min0.1 l/min0.1 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less520 g3/8, 1/2Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
sResponse timeHysteresisPower supply voltageResistancePF2W720Water1.7 to 17.0 l/min1.7 to 17.0 l/min2 to 16 l/min0.1 l/min0.1 l/pulse0 to 50C?5% F.S. or less?3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less520 g3/8, 1/2Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?
Interface Regulator Specifications Caution SV1000 SV2000 SV3000 SV4000-SV4000 P, A, B 0.1 to 0.7 MPa 0.7 MPa Air Maximum at 50C 38.4 g (43.4 g) 32 g (37 g) 86.5 g 80.3 g 103.8 g 97.6 g 178.2 g 171.8 g Interface regulator Applicable model Regulating port Set pressure range Maximum operating pressure Fluid Ambient and fluid temp.
Note 2) The maximum operating temperature for the solenoid valve is 50C. Note 3) The effective area listed is for a single solenoid 2 position valve mounted on a sub-plate. Note 4) Apply pressure from P port in the base for interface regulator. Pilot valves in this series are improved to provide excellent energy saving results.
Features 5 Air Dryer Variations Series IDF E/F/D Standard inlet air temperature type Rated inlet air temperature: 35, 40C [Max. inlet air temperature: 50C, 60C (F and FS type only)] Refer to SMC website for details.
Unit Specifications Model VF1000 VF3000 VF5000 Fluid Air Series VF1000 2-position single/3-position 2-position double 2-position single/3-position 2-position double 22 to 102 psi (0.15 to 0.7 MPa) Standard Operating pressure range 15 to 102 psi (0.1 to 0.7 MPa) Highpressure type 22 to 145 psi (0.15 to 1.0 MPa) 15 to 145 psi (0.1 to 1.0 MPa) Ambient and fluid temperature 14 to 122F (10 to 50C
regulator VEX12001 02 VEX13002 03 04 04 06 10 VEX150VEX17010 12 VEX19014 20 Model VEX11001 02 Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, 2 steps directional control setting and multiple steps pressure control Operation type Air operated, External pilot solenoid Fluid Air 1.0 MPa 0.05 to 0.9 MPa 0.05 to 0.7 MPa 0.05 to 0.9 MPa 0 to 50C
50 kPa to 0.75 MPa1.0 MPa0 to 50C?5% F.S. or less?1% F.S. or less (Connected with PF2A3 ), ?3%F.S. or less (Connected with PF2A2 )?2% F.S. or less (15 to 35C, based on 25C)?3% F.S. or less (0 to 50C, based on 25C)Analog voltage output (non-linear) output impedance 1 k output for display unit PF2A3Voltage output 1 to 5 V (within the flow rate range)Linearity: ?
50 kPa to 0.75 MPa1.0 MPa0 to 50C?5% F.S. or less?1% F.S. or less (Connected with PF2A3 ), ?3%F.S. or less (Connected with PF2A2 )?2% F.S. or less (15 to 35C, based on 25C)?3% F.S. or less (0 to 50C, based on 25C)Analog voltage output (non-linear) output impedance 1 k output for display unit PF2A3Voltage output 1 to 5 V (within the flow rate range)Linearity: ?
50 kPa to 0.5 MPa1.0 MPa0 to 50C?5% F.S. or less?1% F.S. or less (Connected with PF2A3 ), ?3%F.S. or less (Connected with PF2A2 )?2% F.S. or less (15 to 35C, based on 25C)?3% F.S. or less (0 to 50C, based on 25C)Analog voltage output (non-linear) output impedance 1 k output for display unit PF2A3Voltage output 1 to 5 V (within the flow rate range)Linearity: ?
sResponse timeHysteresisPower supply voltageResistancePF2A711Air, Nitrogen5 to 105 l/min5 to 105 l/min10 to 100 l/min1 l/min1 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2A711Air, Nitrogen5 to 105 l/min5 to 105 l/min10 to 100 l/min1 l/min1 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?
sResponse timeHysteresisPower supply voltageResistancePF2A711Air, Nitrogen5 to 105 l/min5 to 105 l/min10 to 100 l/min1 l/min1 l/pulsel/min, CFM x 10-1l, ft3 x 10-10 to 50C?5% F.S. or less?2% F.S. or less?3% F.S. or less (15 to 35C, based on 25C), ?5% F.S. or less (0 to 50C, based on 25C)160 mA or less290 g3/8Heater type3-digit, 7-segment LED?