SMC Corporation of America
Elite Part Number Search
Search Results "JSXFAF-06F-B-A"

dimensions XAH7 depth XL 4-YY depth YL XB XAH7 a b X0.02 c d e XAH7 XC XL X Section XX detail Bore size (mm) a b c d e 40 6.5 4 11 5.5 10.5 WB Z WA Section XX 8.5 50 4.5 13.5 7.5 13.5 11 7 18.5 63 10 17.8 Bottom view L 4-OA through 4-OB counter bore depth OL Section XX WA Z Section XX IA 4-NN through IC 4-MM depth ML R X0.02 HA T-slot for hexagon bolt X0.02 DA DB mIB ID X U VB VA H T PW

Metal bowl with level gauge fitting B B B B p AW3001 220.5 213.5 219.5 240.5 AW4001 272 265 271 292 IN-OUT reversal mounting "'" DimenSions except B are same as the standard type.

Insulation oil A H Polyacetal Note 1) Note 1) Non-leak (10 6 Pam 3/s) Brake oil Water (up to 60C) B P A H Stainless steel Note 1) If using for other fluids, please contact SMC.

A B C E Applicable clip Clip for P7 Clip for P10 Conforms to JIS B 2401 dimensional standard for O-rings for industrial applications.

(A-B)/4 A OFF B+(A-B)/4 B -23No.PS-OMH0005CN-D CH1CH4 5R.D. 2 FSt FSt FSt (5R.D.)

hole Applicable tubing O.D. 6, I.D. 4 Applicable tubing O.D. 6, I.D. 4 Model Number of distribution ports Applicable tubing A B C Number of distribution ports Applicable tubing A B C Model VA4-6 VA6-6 VA10-6 VA16-6 4 6 10 16 36.5 60 88 130 82.5 110.5 152.5 96.5 124.5 152.5 74 102 130 62 90 118 6 VB4-6 VB6-6 VB8-6 4 6 8 48 76 118 6 Note) Insert seal plug (PG1) into the distribution port which

Number of distribution ports 6 6 Oil distributor (VA) (VB) VB6-6 Distribution 4 6 8 4 6 10 16 4 port 6 port 8 port 4 port 6 port 10 port 16 port A B Both sides exhaust One side exhaust VA4-6 Dimensions VA-6 VB-6 4-6.5 hole Applicable tubing O.D. 6, I.D. 4 Applicable tubing O.D. 6, I.D. 4 Model Number of distribution ports Applicable tubing A B C Number of distribution ports Applicable tubing

When used without a guide for a light load. When space is very limited. Series REAS Size: 10, 15, 20, 25, 32, 40 Smooth operation is possible through the use of a special slide bearing. To ensure a permanent path. When used for general transporting. A load can be carried directly by the integrated guide type.

For example, the bore size to move a workpiece with a weight of 37 kg requires a bore size of 43 or more.

AS-FE 1/8 0.07 1/4 0.16 KE 3/8 0.2 1/2 0.4 AS-FG When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. AS-FP AS-FM 4.

1 Direct Operated Solenoid Valve Metal Seal Series VS4 10 Model Flow characteristics Max. (1) operating cycle (cpm) (3) VK Response (2) time (ms) Weight (kg) Model Port size Rc (Nominal size) Number of positions JIS Symbol P A/B A/B EA/EB VZ C [dm 3/(sbar)] C [dm 3/(sbar)] b b Cv Cv AC DC AC DC AC DC VS4110-01 (6A) 3.2 3.2 0.42 0.37 0.86 0.80 1 8 2 (Single) 1,200 180 13 or less 45 or less

Actuating chamber A Actuating chamber A Actuating chamber B Actuating chamber B Discharge Discharge port port Pump chamber B Pump chamber B Pump chamber A Pump chamber A Suction port Suction port Diaphragm Fig. 1 Fig. 2 Fluid flow Air flow 13 11. Sensor mounting (leakage sensor) Series PAF can have a sensor for detecting diaphragm breakage.

The air pressure that flows in acts on diaphragm C and while opposing the force generated by diaphragm B it also acts on diaphragm A opposing the compression force of the setting spring and becomes the set pressure.

(N.O.)3 3 B 1.VFR200 2.VFR210 P8 0.9Nm -10No.VFR2000-OMM0001 ) ARBF2000 P 1.0MPa 1) 0.05to0.83MPa 2) -5to60oC ()3) M5X0.8 (kg) 0.16 PA 5.5 (mm2) P1=0.7MPa,P2=0.5MPa S PB 5.1 DIN DIN DIN DIN / / / / AEA 12 (mm2) DIN 180 P2=0.5MPa S BEB 11 )0.9MPa ) )50oC )2 ) P A B -11 No.VFR2000-OMM0001 01C 01T COM A (A B B AB ) COM AB+ BVFR2100 A COM VFR2200 A COM B 3 400 5 A COM

Series KM Rotary One-touch Fittings Manifold Construction KM11 KM12 Port A: One-touch fitting Port B: One-touch fitting Port A: One-touch fitting Port B: NPT or Rc (PT) female thread KM14 KM13 Port A: One-touch fitting Port B: One-touch fitting Port A: One-touch fitting Port B: One-touch fitting, R(PT) male thread KM16 KM15 Port A: One-touch fitting Port B: One-touch fitting stud Port A:

Pin description A B Output specification 1 DC(+) Output for display unit only 42 62 2 NC/Analog output 3 DC() Output for display unit + Analog output 52 72 4 OUT Flow direction 22 Series PF2W Dimensions: Remote Type Sensor Unit for Water PF2W511-(N)B 148 32 80 70 58 46 45 36 2-Port size 45 2 4-5.5 (44.2) A (mm) A B Output specification Output for display unit only 63 77 Output for display

Clamp Cylinder with Lock with Magnetic Field Resistant Auto Switch Rod Mounting 40, 50, 63 Series CLK2G/CLK2P CLK2G How to Order CLK2P Built-in standard magnet type with magnetic field resistant auto switch CLK2G 50 A Y 100 P4DWSC B Built-in strong magnet type with magnetic field resistant auto switch A Y CLK2P 50 B 100 P79WSE Number of auto switches Bore size Clevis width Nil 2 pcs. 1 pc

Fig. a Fig. b Double Single Double Double Double Single Double Double 1 No. 0 2 4 6 Side A No. 5 Side A 0 2 3 Input block SI unit Tie-rod (2 pcs.) accessory 3 4 Station Station 1 2 3 4 1 2 3 4 7 2 No. 1 3 5 7 Side B No. 1 4 6 Side B Bus cable and termination resistors The cables, connectors, and termination resistors used in CANopen networks shall meet the requirements defined in ISO 11898

MGPS50 50 11 12 A 13 B 14 1 2 3 4 5 50 80 7 8 9 A 10 B 15 16 6 17 NBR 18 NBR 19 A NBR 20 B NBR / (mm) 50 MGP50-PS 19 18 17 80 MG80-PS 20 17 20 GR-S-010(10g 18 18. 18-1.