TYPE Class Instance Attribute Size Description Output 100 100 3 1 INT Position set-point Input 150 150 3 2 INT 2 bytes measured position, 2 bytes diagnostics Figure 16-1 Explicit Messaging 41 - IN20267 Installation and Handling 17. Air supply 17.1. Use clean air.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size Flat head screwdriver 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100
3/16" 1/4" 1/8", 5/32" 3/8" 1/2" 5/32" 3/16" 1/4" 5/16" 3/8" Inch size 3/16", 1/4" 1/4" 5/16" ASF Flow rate (l/min (ANR)) 1050 100 130 290 660 1390 420 920 230 460 Controlled flow (Free flow) Effective area (mm 2) 16 1.5 2 4.5 10 21 6.5 14 3.5 7 Note) Flow rate values are measured at 0.5 MPa and 20C.
3 position cylinder series RZQ provides intermediate stop mechanism. 2 intermediate strokes are possible with only a small extension in total length. First stage stroke can be specified without changing the overall length. High accuracy is achiev, Cylinder, 3-Position, 3-POSITION CYLINDER, 1.41 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, SLIDE TABLE, ACTUATOR, MXS/MXJ GUIDED CYLINDER, IE, 25MM MXS DBL-ACT AUTO-SW, 7.61477 lb, ModelStandard stroke (mm)Additional mass of adjuster optionAdditional mass of functional option 102030405075100125150Rubber stopperShock absorberWith bufferWith end lockAxial piping type S: Stroke
Series CS2 air cylinder is a double acting, non-lube air cylinder. Aluminum die-cast is used for both the rod and head covers, which means a maximum weight reduction of approximately 50% *. This series is available in bore sizes 125mm, 140mm and 160mm with maximum strokes up to 1600mm *. Air cushions are standard on both ends. Other options include auto switches, rod boots, and Rc, NPT or
3 position cylinder series RZQ provides intermediate stop mechanism. 2 intermediate strokes are possible with only a small extension in total length. First stage stroke can be specified without changing the overall length. High accuracy is achieved by an intermediate stop method of pressing metallic components against each other. A tube rod with a large bore which is 70% the piston diameter
Table 4-1 Quality standard for fresh water (tap water) Item Standard value pH25oC 6.5 to 8.2 Electric conductivity (25oC) (s/cm) 100 to 800 Chloride ion (mgCl-/L) 200 or less 2-/L) 200 or less Sulphate ion (mgSO4 Acid consumption (pH4.8) (mgCaCO3/L) 100 or less Total hardness (mgCaCO3/L) 200 or less Calcium hardness (mgCaCO3/L) 150 or less Quality item Ion silica (mgSiO2/L) 50 or less Iron
F Fluid temperature Range of fluid temperature that can be measured by the product. Stands for "full span" or "full scale", and indicates varied analogue output range at rated value. For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S.
26 115/1/60 1/2 215 R134a 8.7 23.6 20.5 70.5 IDF8D-S 16.5 35 115/1/60 3/4 215 R134a 8.7 23.6 20.5 70.5 IDF11C-S 25 53 115/1/60 3/4 215 R22 10.2 24.4 22.4 103.6 IDF15C-S 40 85 115/1/60 1 215 R22 11.0 24.4 24.4 110.2 IDF22C1-S 58 130 220/3/60 1 215 R22 11.6 29.5 26.8 133 IDF37C1-S 96 215 220/3/60 1 1/2 215 R22 12.6 36.6 28.7 160 Flow readings at 100OF inlet temperature; 100OF ambient and 100
V 12 V 5 V, 12 V Grommet No Relay, PLC 100 V or less Yes 100 V, 200 V No 200 V or less 2-wire 24 V PLC Terminal conduit 12 V Relay, PLC Yes 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indication) Solid state auto switches marked with are produced upon receipt of order.
DIN terminal Terminal 1 2 + + Pilot Valve Assembly Specifications Grommet (G), Grommet terminal (E), Conduit terminal (T), DIN terminal (D) How to Change Passage State Electrical entry Enclosure Lead wire color Dusttight 100 VAC: Blue, 200 VAC: Red, 24 VDC: Red/Black 100, 200, 110, 220, 240 DC AC (50/60 Hz) Coil rated voltage (V) 24, 12 Allowable voltage fluctuation 15 to +10% of rated
Output pressure (kPa) 40 0 0 Out 60 0.5 0.5 80 1.0 1 0 2 4 6 8 10 0 25 50 75 100 0 25 50 75 100 Input signal (%F.S.) Count Input signal (%F.S.)
To booster lube From booster lube To booster lube From booster lube A B 63 63 80 85 90 100 C Port size Rc INA-11-402 INA-11-403 INA-11-404 INA-11-405 INA-11-406 INA-11-407 Model 1 4 3 8 15 15 15 20 22 22 141 164.5 170 180 230 251 , , 1 4 3 8 1 2 B C D E F Port size Rc Part no. A 3 4 , 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 1 1 3 4 ALBA90-10 ALBA90-20 14-13-19
(choked flow) Subsonic flow : Flow greater than the critical pressure ratio Standard condition : Air in a temperature state of 20C, absolute pressure 0.1 MPa (= 100 kPa = 1 bar), relative humidity 65%. It is stipulated by adding the abbreviation (ANR) after the unit depicting air volume.
How to Order ZFB 100 04 IN/OUT applicable tubing O.D.
Mounting style Number of auto switches F: Flange on the rod side B: Basic style Rotation Linear motion 0 1 2 OS SS 2S O2 S2 Nil 0 1 2 SO 2O Auto switch Nil Without auto switch (built-in magnet) Size/Standard stroke (mm) For the applicable autoswitch model, refer to the table below. 32 40 5, 10, 15, 20, 25, 30, 40, 50, 75, 100 Nil X Standard Made to Order Refer to pages 352 and 353 for
Non-rotating Double Power Cylinder 20, 25, 32, 40, 50, 63, 80 Series MGZ How to Order 40 M9BW 100 Z MGZ Made to Order For details, refer to page 429. Mounting style Nil L F G Basic style Transaxial foot style Rod flange style Head flange style Number of auto switches 2 pcs. 1 pc. n pcs.
V Relay, PLC 2-wire A90V IC circuit 100 V or less 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.
2 Fine Lock Cylinder with Guide Series MLGC 20, 25, 32, 40 How to Order MLGC B R E S 32 100 H7BW L Number of auto switches Guide cylinder (Compact style with fine lock) 2 pcs. 1 pc. n pcs.