Magnet: Built-in, Series: with End Lock, Mounting: Axial Foot, Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 100mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Rear Locking, Release Type: Locking, Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Series: with End Lock, Mounting: Double Clevis, Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: Rc, Stroke: 75mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Front Lock, Release Type: Non-locking Type, Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Series: with End Lock, Mounting: Front Flange, Tube Material: Aluminum Tube, Bore Size: 63mm, Port Thread: Rc, Stroke: 350mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Rear Locking, Release Type: Locking, Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Series: with End Lock, Mounting: Front Flange, Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Rear Locking, Release Type: Non-locking Type, Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Content 0 10 1 11 2 12 3 13 4 14 5 15 6 16 7 17 Unit diagnostic status 1 7 6 5 4 3 2 1 0 Byte 3 Bit No.
No.EX-OMV0023-A PRODUCT NAME SI unit for Ethernet POWERLINK MODEL / Series / Product Number EX260 Series Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Installation and Wiring 10 Installation 10 Wiring 11 LED Indication and Settings 15 Configuration 17 Troubleshooting and Maintenance 21 Specifications 26 Specifications 26 Dimensions
Report fault by diagnostics, show on diagnostic LED, and inhibit turn on. 11 Reverse supply protection External installation error Polarity diode No function and no supply to valves. In addition: The device goes into the Fail-safe state if it detects a fault. In Fail-safe state the output is "Off".
There are differences in the displayed values when using more than Refer to Trouble No.11 one product. The display accuracy Refer to Trouble No.12 does not meet the specifications. Applied voltage does Refer to Trouble No.8 not match with the displayed pressure value. The Display Refer to Trouble No.13 measurement unit cannot be changed. Buttons do not work.
There are differences in the displayed values when using more than Refer to Trouble No.11 one product. The display accuracy Refer to Trouble No.12 does not meet the specifications. Applied voltage does Refer to Trouble No.8 not match with the displayed pressure value. The Display Refer to Trouble No.13 measurement unit cannot be changed. Buttons do not work.
No.TQ0010298-OM003-A PRODUCT NAME Digital pressure switch for energy-saving control ejector MODEL / Series / Product Number ZME-ZSE***-A Table of Contents Safety Instructions 2 Model indication and How to order 9 Summary of Product parts 10 Definition and terminology 11 Mounting and Installation 14 Installation 14 Wiring 15 Wiring 15 Internal circuit and wiring example 16 Easy Setting 17
No.PF-OMS0001CN-A // PFMC7501 PFMC7102 PFMC7202 2 10 11 12 14 15 17 18 [] 22 OU1OUT2 {3 ] 23 [] 25 26 F0 27 F1 OUT1 29 F2 OUT2 37 F3 42 F10 43 F20 47 F22 48 F30 49 F31 50 F80 OFF 51 F81 52 F82 53 F90 54 F98 56 F99 57 58 62 63 65 66 66 69 71 -1No.PF-OMS0001CN-A (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO
Units display (Accumulated flow) Indicates the flow measurement units currently selected. 11 No.PF-OMU0002-D Definition and terminology Term Definition A The total amount of fluid that has passed through the device. If an instantaneous flow of 100 L/min lasts for 5 minutes, the accumulated flow will be 5 x 100 = 500 L.
No.10 There are differences Refer to Trouble in the displayed values when using more than one No.11 pressure switch. The display accuracy Refer to Trouble does not meet the No.12 specifications. Applied voltage does Refer to Trouble not match with the No.8 displayed flow value. The Display Refer to Trouble measurement unit No.13 cannot be changed. Buttons do not work.
No.PF-OMG0010-H PRODUCT NAME Digital Flow Switch (Integrated display type) MODEL / Series / Product Number PF2A7##H Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 11 Definition and terminology 12 Mounting and Installation 14 Installation 14 Piping 15 Wiring 16 Outline of setting 18 List of outputs 19 Function selection mode 20 F_0 Initialize
Rc(NPT)11/4 40 to 42 Nm Hysteresis H_1 Item Default setting / With the temperature sensor in parenthesis (Displayed alternately) Flow [L/min] Rc(NPT)11/2 48 to 50 Nm [F 3] Response time setting 1 second Temperature upper limit exceeded If the tightening torque is exceeded, the product can be broken. If the correct tightening torque is not applied, the fittings may become loose.
Piping port (IN side) 11/4 54 mm Measurement mode Bracket (Option) 11/2 54 mm *: Green: Flashes once. PF3W5 -1 (Analogue 1 to 5 V type: Without temperature sensor) Flashes twice. PF3W5 -2 (Analogue 4 to 20 mA type: Without temperature sensor) Flashes three times. PF3W5 -1T (Analogue 1 to 5 V type: With temperature sensor) Tighten to the specified torque for piping.
Otherwise it can cause failure or malfunction of the system. 11/4 54 mm Temperature upper limit exceeded Flow range, unit specification and mounting of temperature sensor are displayed Set value Sets the ON or OFF point of the switch output. 50 oC 11/2 54 mm The fluid temperature is above 110 oC. Reduce the fluid temperature.
If the minimum setting unit is 1 L/min, the display will change in 1 L/min steps, e.g. 10..11..12 L/min. -14No.LV50***-OMQ0002-G Term Meaning O Operating fluid temperature Range of fluid temperature that can be measured by the product. Operating pressure range The pressure range in which the product can be used.
If the minimum setting unit is 1 L/min, the display will change in 1 L/min steps, e.g. 10..11..12 L/min. M Minimum setting unit -15No.LFE*-OMZ0011 Term Meaning O Operating fluid temperature Range of fluid temperature that can be used by the product. Operating pressure range The pressure range in which the product can be used.
Do not continue idling except for priming the pump. 5 11. Condensation and freezing of the pilot port The location around the switching valve and the air exhaust port can cool down quickly due to expansion of the supply air, and this may cause condensation on the piping and the condensation may freeze during operation in winter.