Body Type: O (Manifold), Valve Option: E (Continuous Duty), Voltage: 3 (110VAC, 50/60 Hz), Electrical Entry: C (Conduit)
Body Type: Manifold, Valve Option: Standard, Voltage: 110VAC, 50/60 Hz, Electrical Entry: Conduit, Light & Surge Suppressor: -, Port Size: -, Thread: -, CE/UKCA Compliant: -
Body Type: Manifold, Valve Option: Continuous Duty, Voltage: 110VAC, 50/60 Hz, Electrical Entry: Conduit, Light & Surge Suppressor: -, Port Size: -, Thread: -, CE/UKCA Compliant: -
Function 1: Single, Sealant: Metal Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: Yes, Manual Override: Locking Knob Style
Function 1: Single, Sealant: Rubber Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: Yes, Manual Override: Locking Knob Style
Function 1: Single, Sealant: Rubber Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: Yes, Manual Override: Locking Lever Style, Enclosure: -, Sub-plate: -, Thread: -
Function 1: Closed Center, Sealant: Rubber Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: Yes, Manual Override: Locking Lever Style, Enclosure: -, Sub-plate: -, Thread: -
Function 1: Exhaust Center, Sealant: Rubber Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: Yes, Manual Override: Locking Lever Style, Enclosure: -, Sub-plate: -, Thread: -
Function 1: Double, Sealant: Rubber Seal, Function 2: Standard (1W DC, AC), Coil Voltage: 110VAC 50/60Hz, Light & Surge Suppressor: Yes, Manual Override: Locking Lever Style, Enclosure: -, Sub-plate: -, Thread: -
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Also, take measures to prevent ingress of water and foreign matter from the breathing port of the diaphragm. 5-5-10 1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.
M3 M3x0.5 M5 M5x0.8 01 18 02 14 03 38 04 12 Courtesy of Steven Engineering, Inc. !
type: White color L type: Black color (Mounting hole) B C D E F G H Model A 3 8 Rc3 8 Rc3 8 Rc3 8 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL-03-04-04 Rc 133 52.45 42 19 3.5 19 20.95 20.95 133 52.45 42 19 3.5 19 151.1 60.95 47.7 19 3.5 24 26.75 151.1 60.95 47.7 19 3.5 24 26.75 I J K L M N O Model 3 8 Rc3 8 Rc3 8 Rc1 2 Rc1 2 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL
-X538 34.4 75.2 118.7 262.7 AW40-04G-A Y400T-A E400-04-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 AW40-04G-A Y400T-A E400-04-A 17 VP500/700-X536, X538, X555 Specific Product Precautions Be sure to read this before handling.
Blanking plug KQ2PDimensions 23 04 06 A L D Model Applicable fittings size d It is inserted into an unused cylinder port and SUP/EXH ports.
AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 Silencer BC Sintered Body Type Series AN Specifications/Model Ideal for the exhaust of a compact valve or pilot air.
Example) AF30-03B-2R-X430 X430 X440 Low temperature High temperature Symbol 30 40 50 60 20 Body size Description 30 40 50 60 Body size Description Symbol Nil N Note 1) Rc NPT G F Note 2) Thread type Nil N Note 1) Rc NPT G + F Note 2) Thread type 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 + 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Port size Port size + + Without mounting option With bracket Nil B Note
Symbol A R P 4 Metric sizes 03 04 06 3 4 6 Valve type N.C. 0 N.C.