12 33 . 13 1LECGPR1 . 13 2DIN LECGPR1D . 13 34 . 14 1 . 14 2 . 14 4 . 15 41 ADDRESS,B RATE . 15 42 CN2SW . 16 43 LEC . 17 44 SIEMENS PLC S7 . 19 5 . 21 51 CN4: . 21 52 CN3: . 21 53 CN1:CONT . 21 54 CN2:PC/TB . 22 1 - 6CN . 23 61 . 23 62 . 23 63 . 24 . 25 7CN3: . 26 8CN1:IF CONT . 27 81 . 27 82 . 29 9CN2:TB/PC . 30 91 . 30 10LED . 31 101 LED . 31 102 IF LED . 31 11 . 32 111

Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Common Pilot EXH, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 3/8, Thread: G, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in, Insert Plug w/Lead Wire, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/8, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: External Pilot, Junction Cover: One-piece Junction Cover, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: One-piece Junction Cover, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Plug-in w/Terminal Block, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPT, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Non Plug-in Individual Lead Wire Entry, Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Base Mounted Plug-in for Serial Transmission, Pilot Type: -, Junction Cover: -, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: -, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: Base Mounted Plug-in for Serial Transmission, Pilot Type: -, Junction Cover: -, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 1/4, Thread: NPTF, Control Unit: -, Voltage of Air Release Valve: -, Q: -

Base Mounted Wiring: 01 (Plug-in, Insert Plug w/Lead Wire), Pilot Type: Internal Pilot or None, Junction Cover: Separate Junction Cover or None, Stations: 11 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 20/30, Port A,B: Top)], Port Size: 02 (1/4)