Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V Approx.
Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
This produces an air cushion cylinder which retains the merits of a compact design. Operating principle A + A' A' qWhen the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A. wAfter piston seal H has passed the air passage A, exhaust is discharged only from A'.
Bore size (mm) Auto switch mounting surface 20, 25 63, 80, 100 32, 40, 50 Port side Port side Port side C A C A C A B B B Auto switch mounting surface Auto switch mounting surface Auto switch mounting surface Auto switch model A, B, C sides Port side Port, A, B, C sides Port, A, B, C sides 1. BQ-2 2. BQ2-012 Two kinds of auto switch mounting brackets are used as a set.
For the angle adjusting type, angle adjusting screws are mounted to the left cover. k e of y e gr g Angle adjusting screw o n o Angle adjusting screw ra v e n io 1 8 at 0 ot R n io ct re di g n ti us n A dj io n a gl ct e re e gl a di dj n g u in A st st in u g dj 0 di 0 a re 8 8 e ct gl 1 1 io n R n A e R e o v v o t o o a t o a o ti o r ti r g g n o n y y r a e e r n k a k g f o e n f
For the angle adjusting type, angle adjusting screws are mounted to the left cover. k e of y e gr g Angle adjusting screw o n o Angle adjusting screw ra v e n io 1 8 at 0 ot R n io ct re di g n ti us n A dj io n a gl ct e re e gl a di dj n g u in A st st in u g dj 0 di 0 a re 8 8 e ct gl 1 1 io n R n A e R e o v v o t o o a t o a o ti o r ti r g g n o n y y r a e e r n k a k g f o e n f
Hs A B A B 32 to 100 D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V Approx.
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
10.5 [5m ] L E C P *B* (a) (b) 2 A B-1 L 1 A A-1 (b) 6 A B-1 B B-2 1 1.5m 5 A A-1 B A-2 3 3 3m B B-2 COM-A/COM B-3 4 B A-2 COM-B/A-3 5 5m (c) COM-A/COM B-3 Shield COM-B/ A-3 Vcc B-4 12 GND A-4 13 Vcc B-4 A B-5 7 GND A-4 A A-5 6 A B-5 B B-6 9 A A-5 S B A-6 8 (d) B B-6 3 B A-6 (a) + B-1 4 A-1 5 + B-3 1 2 A-3 (a) (8) (14.2) B1 A1 (b) 2 1 (17.7) (14) (18) (10.2) 6
L R O D T H R E A D X A O P T I O N Thread Form Code M .
R1 ND MM ND MM R1 MM E1 ND NX1 A U1 R2 H Z E1 NX U1 L1 A A NX A1 (Min.) A1 U1 L1 Applicable bore size 20 25, 32 40 MM L1 NX NDH10 R1 E1 A1 U1 A A H MM NDH10 NX1 U1 R2 Y Z Part no.
This produces an air cushion cylinder which retains the merits of a compact design. Working principle A + A' A' A A' A' R H R H Piston seal When the piston is retracting, exhaust is discharged from both A and A' until piston seal H passes the air passage A. After piston seal H has passed the air passage A, exhaust is discharged only from A'.
Part no.: RQB32-47 A special tube is manufactured for a 47mm stroke.
L R O D T H R E A D X A O P T I O N Thread Form Code M .
Consider the possibility of a reduction in the circuit air pressure caused by a power failure. Operate the product within a range such that the ! Caution There is a danger of workpieces dropping if there is a decrease of thrust due to a drop in circuit pressure caused by piston will not collide and be damaged at the stroke end. a power outage, etc.
Actuator drive When an actuator, such as a cylinder, is to be driven using a valve, take appropriate measures to prevent potential danger caused by actuator operation. 2. Effect of back pressure when using a manifold Use caution when valves are used on a manifold, as actuator malfunction due to back-pressure may occur.
Hv Auto Switch Proper Mounting Position Solid state auto switch Bore size (mm) 2-color indication solid state auto switch Reed auto switch B C A B Hv A B C A B Hv A B Hv A B C D-A9 D-A9V D-M9 D-M9V D-F8 D-M9W A B Hv D-M9WV A 36 25 16 36 25 15 32 21 20 32 21 17.5 18 7 25 32 21 20 32 21 17.5 8 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
A 2.0 (50.8) 2 x 10-32 UNF depth 0.35 (8.9) (Mounting hole) 1.5 (38.1) 45 A A Bottom view Connections inch A (mm) FV4 MV4 TW6 FV8 MV8 TW8 FV12 MV12 TW12 2.00 (50.8) 1.375 (34.9) 2.425 (61.6) 1.79 (45.4) 3.50 (88.9) 3.25 (82.6) Elgiloy is a registered trademark of Elgiloy Specialty Metals.
Port size 01 C4 C6 Rc 1/8 4 cassette 6 cassette Solenoid on opposite A port Nil 1(P) port: Rc 1/8 3(R) port: Rc 1/8 Solenoid on same side as A port 2(A) port: Rc 1/8 S Valve stations Type S42 (Solenoid on same side as port A) 01 1 station 1(P) port: Rc 1/8 3(R) port: Rc 1/8 20 20 stations 2(A) port: Rc 1/8 4-13-7 8 Series VKF300 Dimensions: Manifold Body ported Common SUP, Common EXH/Top