SMC Corporation of America
Elite Part Number Search
Search Results "VEX1100-02-FG"

Size: Body Ported, Operation: Air Operated Style, Port Size: 1/8, Thread: NPT, Voltage: -, Lead Wire: -, Surge Suppressor: -, Option: -

Size: Body Ported, Operation: Air Operated Style, Port Size: 1/4, Thread: NPTF, Voltage: -, Lead Wire: -, Surge Suppressor: -, Option: -

Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Standard, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: Rc, Supply Side, Connection Diameter: 1/8, Control Side Connection Type: Rc, Control Side, Connection Diameter: 1/8, Pressure Gauge:

Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Standard, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: [NPT] NPTF, Supply Side, Connection Diameter: 1/8, Control Side Connection Type: [NPT] NPTF, Control Side, Connection Diameter: 1/8,

Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Standard, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: G, Supply Side, Connection Diameter: 1/4, Control Side Connection Type: G, Control Side, Connection Diameter: 1/4, Pressure Gauge: [Not

Regulator, Pressure Boosting Valve: Regulator, Regulator Type: Standard, Shape: Standard, Operating Environment: Standard, Compatible Fluid: Air, Exhaust Mechanism (Air Bleed): [Included] Yes, Reverse Flow Function (Relief): No, Supply Side Connection Type: [NPT] NPT, Supply Side, Connection Diameter: 1/4, Control Side Connection Type: [NPT] NPT, Control Side, Connection Diameter: 1/4, Pressure

DG DG DG SLD SLD SLD CC-Link-dedicated cable FG CC-Link-dedicated cable 5 FG FG DIP SW.1 DIP SW.2 ON EX180 Series for CC-Link 6 1 Figure 2 PWR(V) PWR L ERR 0 1 2 3 4 5 6 7 8 9 10 1 2 1 Thank you for purchasing an SMC EX180 Series Fieldbus device (Hereinafter referred to as "SI unit").

If a cable with any other specifications is used, normal data transmission cannot be guaranteed. -12No.EX-OMB0014-H (4) The CC-Link-dedicated cables shield wire (SLD) should be connected to the FG terminal of the SI unit. For the EX12#-SMJ1, the "SLD terminal" and "FG terminal" are common. Therefore, connect 3 wires to the "FG Terminal" as shown in Fig. 4.

RESET GND FG Connect to GND of the counter cable. RESET Reset signal is output. Connect to RESET of the counter cable. FG FG terminal. Connect to FG of the counter cable. 6.2 Counter plug wiring The wiring of the counter cable (LATH3-) and Multi-counter (CEU5) is shown below. Refer to the Multi-counter (CEU5) operation manual for further details.

FG Phase A A-phase pulse signal is output. Red Connect to Phase A of the counter cable. GND Sensor input common. Light Grey Connect to GND of the counter cable. RESET Reset signal is output. Yellow Connect to RESET of the counter cable. FG FG terminal.

For the EX140-SMJ1, the "SLD terminal" and "FG terminal" are common. Therefore, connect 3 wires to the "FG Terminal" as shown in Fig. 4. Fig. 4: Wiring to the FG terminal on the SI unit When connecting 3 wires to the FG terminal, crimp 2 wires together into one crimped terminal as shown in Fig. 5. Use another crimped terminal for other wires.

Single power supply Figure 3 Figure 4 : Communication connector FG and FG terminal are connected inside the SI unit.

(A clearance of 40 or more is required.) 60 (96.7) (60) (49.6) 110.8 35.5 132.2 94 96.7 35.5 Motor 100 60 102 60 42 170 163 108.7 67 22.2 Controller 60 34 31.8 48.7 4-9.5 counterbore depth 5.4 5.5 through 19.5 FG terminal M3 Workpiece mounting center line 5 15.5 5 7 4-M5 x 0.8 depth 9 7.1 (Max. 10.1) 17.5 37 (51.8) 87.3 T-slot section for mounting 198 + Stroke 6 8.5 5.3 3 Motor position TA

r FG !1 !2 t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 Switch the mode between manual and auto. Mode swith !3 !4 Stop position, the value set by 8 and alarm information are displayed. 7-segment LED SET Decide the settings or drive operation in Manual mode. Set button Assign the position to drive (1 to 14), and the origin position (15).

Speed Controller with One-touch Fitting Stainless Series Series AS-FG/ASD-FG . Series AS-FG Speed Controller with One-touch Fittin Stainless Series. 5 5 6 7 9 11 11 11 11 12 13 13 13 15 15 16 16 16 17 17 18 19 21 22 22 23 24 25 27 27 27 29 30 31 31 31 32 34 35 35 35 36 36 37 37 37 38 38 39 39 39 41 42 43 43 43 44 45 46 46 Specifications. How to Order . Construction. Dimensions .

Yellow RESET Connect to the FG wire of the counter cable. Green FG Use the I/O cable (LATH2-m) to connect a PLC, etc., to the CN5 parallel I/O connector. The wiring is specific to the type of parallel I/O (NPN or PNP). Please refer to the wiring diagrams below for correct wiring of NPN and PNP type controllers.

r FG !1 !2 t y u i o !0 !1 !2 !3 !4 !5 !6 !7 !8 Switch the mode between manual and auto. Mode swith !3 !4 Stop position, the value set by 8 and alarm information are displayed. 7-segment LED SET Decide the settings or drive operation in Manual mode. Set button Assign the position to drive (1 to 14), and the origin position (15).

Note Ground the FG terminal with a ground resistance of 100 or less. Tighten the FG terminal (M3 round head combination screw) firmly with a tightening torque of 0.3 Nm. Tighten the connector fixing screws (M2.5 slotted head screws) firmly with a tightening torque of 0.2 to 0.3 Nm. A. Dual power supplies B.

AS-FE KE AS-FG 2. The products in this catalog are not designed for the use as stop valve with zero air leakage. AS-FP Unlocked Locked A certain amount of leakage is allowed in the product's specifications. Tightening the needle to reduce leakage to zero may result in equipment damage. 5. Check the degree of rotation of the needle valve.