C6: 6 (SMC) N7: 1/4" (SMC) Applicable tubing O.D. C6: 6 (SMC) C8: 8 (SMC) C10: 10 (SMC) N7: 1/4" (SMC) N9: 5/16" (SMC) N11: 3/8" (SMC) (11) (47.7) One-touch fitting [PE: Pilot EXH port] Applicable tubing O.D.
S Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R Lead wire length U 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
Without lead wire Nil 6 10 15 20 25 30 300 600 1 2 3 Blue (2) For 100 VAC For 200 VAC Another VAC 1000 1500 2000 2500 3000 Socket Hook Red (2) Gray (2) 4 Red: +, Black: For DC Note) When ordering a valve in which the length of the wire is more than 600 mm, be sure to indicate the model number of valve without connector and connector assembly. Ex.)
VJ10-20-4A-6 2 pcs. 5A 10 ZS ZP (For DC) 4A 20 VJ10 6 Lead wire length ZCU Nil 30 50 0.6 m 3 m 5 m (For 100 VAC) 1A 36 VJ10 6 AMJ (For 110 VAC) Note) If ordering switch with 5 m lead wire, specify both switch and lead wire with connector part numbers. Ordering example) ZX100-K150Z-ECN1 pc. VJ10-20-4A-6 2 pcs. ZS-10-5A-50 1 pc. 3A 36 VJ10 6 Misc.
30 B 70 70 108 108 Model A 174 174 234 234 ALT-5 ALT-5-IS ALT-9 ALT-9-IS 449 482 1.17-14 Oil Distributor VA, VB/Nylon Tubing Related Products Oil Distributor Series VA, VB How to Order V A 4 6 Applicable tube O.D. 6 6 Oil Distributor Number of distribution ports (VA) (VB) VB6-6 Distribution 4 ports 6 ports 8 ports 4 ports 6 ports 10 ports 16 ports 4 6 8 4 6 10 16 Both sides exhaust One side
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
or less 40 or less 30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
Port block assembly (cassette type) Port block assembly (screw-in type) How to Order Connector Assembly For DC : SY100-30-4AFor 100VAC : SY100-30-1AMounting screws For 200VAC : SY100-30-2AFor other AC : SY100-30-3AWithout lead wires : SY100-30-A (connector, socket x 2pcs. only) Lead wire length 300mm 600mm 1000mm 1500mm 2000mm 2500mm 3000mm 5000mm Nil 6 10 15 20 25 30 50 Fitting assembly
Weight 30 g (ZL3-) JSY3140 5 5-port solenoid valve JSY3000 series Specific Product Precautions Z Multistage ejector ZL 3 6 series Exhaust noise (Reference values) Z ZL3 6 5 Manual override Model ZL3 ZL6 Exhaust noise [dB(A)] 68 Electrical entry Refer to page 26.
Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
Confirm that the connector portion does not move. 14.9 Gray: Ground Black: DC24V 10% ( power supply for input and control ) Blue: 0V ( for input and control ) White: DC24V+10%/-5% ( for solenoid valves/output ) 18 48 34 Straight connector Type Angle connector Type EX500-AP -S EX500-AP -A 6 30 5 50 31.3 28.3 6 Socket Connector Pin Layout 4 3 1 5 30 5 50 2 B. Single power supply system A.
Note2) For thread standard, refer to page 2-6-39.
This will cause a malfunction. 14-11-6 6 Pressure Gauge Guide How to Order G M C 46 10 01 X2 Option Specifications Symbol Pressure gauge F.R.L.
AV Tightening Torque when Piping Connection thread Applicable torque (Nm) M5 x 0.8 1.5 to 2 1/6 rotation 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 AU Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 Rc 3/4 Rc 1 Rc 1 1/4 Rc 1 1/2 Rc 2 AF Model Connection R AN120 AN110 AN200 AN300 AN400 AN500 AN600 AN700 AN800 AN900 Effective area (mm2) AR Courtesy of Steven Engineering, Inc
tubing A B C Model Number of distribution ports Applicable tubing A B C VA4-6 VA6-6 VA10-6 VA16-6 4 6 10 16 36.5 60 88 130 6 VB4-6 VB6-6 VB8-6 4 6 8 74 102 130 96.5 124.5 152.5 62 90 118 82.5 110.5 152.5 48 76 118 6 Note) Insert seal plug (PG1) into the distribution port which is not used.
Construction 3 1 Component Parts Description Material No. q w e r t y u 4 Solenoid coil Body Fixed armature Armature Return spring Poppet Diaphragm assembly Resin Stainless Steel Stainless Steel Stainless Steel NBR NBR, Resin 2 5 6 7 4.3-5 Series VQ20/30 Dimensions/Series VQ20 In-line style/Grommet(G) VQ21A1-mGm-m Dotted line: Bracket mounting style (-F) 4.3-6 Series VQ20/30 For Dry Air,
-6 connector assy, VQ1000/VQ20/VQ30 VALVE $2.55 This product is obsolete.
-6 connector assy, VQ1000/VQ20/VQ30 VALVE $2.55 This product is obsolete.
-6 connector assy, VQ1000/VQ20/VQ30 VALVE $2.55 This product is obsolete.
Troubleshooting P.23 6. Construction P.26 7. Auto switch precautions P.30 1) Applicable auto switches P.30 2) Precautions for use P.32 -1- 3A 3/5 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.