Nm Moment Nm Moment Nm 4 4 4 CX CY1F15 3 3 3 DCY1F10 2 2 2 -X CY1F15 CY1F15 20CY1F10 CY1F10 1 1 1 Data 0.5 0.5 0.5 500 100 300 50 500 100 300 50 500 100 300 50 Piston speed mm/s Piston speed mm/s Piston speed mm/s (4) CY1F/m1 (5) CY1F/m2 (6) CY1F/m3 (7) CY1F/m4 30 30 30 30 20 20 20 20 CY1F25 CY1F25 CY1F25 CY1F25 10 10 10 10 CY1F15 CY1F15 CY1F15 5 5 5 5 Load mass kg Load mass kg Load mass
External Connections . 30 5.1 PWR: Power supply connector . 30 5.2 MOT: Motor connector, ENC: Encoder connector . 30 5.3 SI: Serial I/O Connector . 30 (1) Connecting the teaching box . 30 (2) Connection with a PC . 31 5.4 CC-Link communication connector . 31 6.
Bore size (mm) 10 15 25 No. RB0805-X552 RB1006-X552 2.
Adjustment bolt (A) Adjustment bolt (B) For 90 rotation Single vane (S): 80 to 100 adjustable Double vane (D): 85 to 95 adjustable A B 180 Adjustment range of adjustment bolt (A) Adjustment range of adjustment bolt (B) 10 10 22.5 Size Allowable radial load (N) Allowable thrust load (N) Allowable moment (Nm) 1 10 15 20 0.3 A B Positioning pin hole 3 15 30 40 0.7 7 30 60 50 0.9 Adjustment bolt
For 90 rotation Single vane (S): 80 to 100 adjustable Double vane (D): 85 to 95 adjustable A B 180 Adjustment range of adjustment bolt (A) Adjustment range of adjustment bolt (B) 10 10 22.5 DSize Allowable radial load (N) Allowable thrust load (N) Allowable moment (Nm) 1 10 15 20 0.3 A B Positioning pin hole 3 15 30 40 0.7 Adjustment bolt (A) Adjustment bolt (B) 7 30 60 50 0.9 20 For 180
Up to 300 13 5 18 9 65.3 15.5 10 28 19 5 8 30 13 M8 x 1.25 41 15 24 20 0 0.033 Up to 300 17 6 22 9 70.5 19.5 10 33.5 19 5.5 10 30 13 M10 x 1.25 45 15 30 26 0 0.033 Up to 300 17 6 22 9 76.5 19.5 10 37.5 19 5.5 12 30 13 M10 x 1.25 45 15 34.5 26 0 0.033 0 0.039 Up to 300 22 8 24 10 84.5 21 15 46.5 30 7 14 39 16 M14 x 1.5 50 21.5 42.5 32 Clevis pin and snap ring (cotter pin for 40) are packaged
CV Standard Stroke MVGQ Bore size (mm) Standard stroke CC 10 15, 30, 45, 60 16 15, 30, 45, 60 RB Made to Order Specifications (For details, refer to page 10-21-1.)
SX3000-64-3A In common between +COM and COM.
SX3000-64-3A In common between +COM and COM.
CPRM_SEL_ MON1 14 15 16 17 CPRM_SEL_ MON2 18 19 20 21 Reserved MONITOR1 22 23 24 25 MONITOR2 26 27 28 29 MONITOR3 30 31 8-71 8 MECHATROLINK-III Commands Related Parameters Parameter No.
26.5 MXQ-A827 5 16.5 3 8 3.5 M6 x 1 MXQ-A827-X11 15 26.5 MXQ-A827-X12 25 36.5 MXQ-A1227 5 20 4 12 4 M8 x 1 MXQ-A1227-X11 15 30 MXQ-A1227-X12 25 40 MXQ-A1627 5 24.5 5 14 4 M10 x 1 MXQ-A1627-X11 15 34.5 MXQ-A1627-X12 25 44.5 MXQ-A2027 5 27.5 6 17 5 M12 x 1.25 MXQ-A2027-X11 15 37.5 MXQ-A2027-X12 25 47.5 MXQ-A2527 5 32.5 6 19 6 M14 x 1.5 MXQ-A2527-X11 15 42.5 MXQ-A2527-X12 25 52.5 A B D C M
Refer to the dimensions on page 15 for the mounting dimensions. (35) (25) 5.5 1.25 L Dimension [mm] No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 L 23 35.5 48 60.5 73 85.5 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 No. 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 L 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5
32 32 R 40 48 56 58.5 41 50 60 68 64 76 86 91 18 24 30 35 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5 M5 VCA21 VCA31 1/4 1/4, 3/8 3/8, 1/2 3/4 VCA41 4 Series VCA How to Order Manifolds (VCA20) VV2C A 2 02 02 How to Order Manifold Assemblies (Example) Enter the valve and option models to be mounted under the manifold base part number.
0.5 LECSS-S7 LE-S70.5 25 15 0.5 LECSS-S8 LE-S80.9 35 15 0.7 1.
(W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 15/60 Hz Inrush (1) Apparent power (VA) [Current mA] AC Note) 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Holding (2) Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Note 1) At rated voltage Note 2) Plug-in should be ZNR.
Response time ms (at 0.5MPa) With surge voltage suppressor S, Z type 15 or less 13 or less 20 or less 35 or less Type of actuation Without surge voltage suppressor 2 position single 2 position double 3 position 4 position dual 3 port valve 12 or less 10 or less 15 or less 30 or less Weight Table Valve model Type of actuation Port size A, B Weight g Single Double Closed center Exhaust center
Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 12.4 Controller input signal response Signal timing Check the timing of the signal from the PLC to the controller. time When power is applied,
30 31 30 33 42 42 0D 0A Read Address Quantity to Read Hi Lo Hi Lo 30 30 34 30 30 30 30 31 Response message (Slave to Master) Start Slave Address Function Data LRC End 3A 30 31 30 33 41 34 0D 0A Byte Count Read Data1 Hi Lo 30 32 30 39 34 4D HECR 5-6 MODBUS communication function 5.6 Function codes The table berow function codes to read or write register.
Caution
Allowable load Size Allowable radial load(N) Allowable thrust load(N) Allowable moment (Nm) 1 20 15 0.3 3 40 30 0.7 7 50 60 0.9 20 60 80 2.9 Table rotation range Angle adjustment is possible as shown in the Fig. 2 below using adjustment bolts (A) and (B).