If Switch is ON Turn the switch to OFF. (2) Connect 85 to 240 VAC to the terminal block. (3) Connect the earth ground (resistance value 100 ohms or less) to the power terminal block (FG). 2) Valve output (1) Make sure the power supply voltage and valve rated voltage match. (2) Connect the valve to the output terminal block in order from SV1. Fig. 3 Valve output wiring 5.
If Switch is ON Turn the switch to OFF. (2) Connect 12,24 to 48VDC to the terminal block. (3) Connect the earth ground (resistance of 100 ohms or less) to the power terminal block (FG). 2) Valve output (1) Make sure the power supply voltage and valve rated voltage match. (2) Connect the valve to the output terminal block in order from SV1. Fig. 3 Valve output wiring 5.
T2 T1 ExpansionValve ExpansionValve PressureSensor PressureSensor PressureSensor Not connected at option Z/Z1 Option T1 Option T Flow Sensor t t EV1 EV2 PTSensor PS1 PS2 PS3 PT FL WH WH BK BK DOUT2(temp) DOUT( flow) PM DC(+) DC(-) M M OUT OUT OUT + + + 3 3 3 2 2 2 1 1 1 3 2 3 2 1 1 4 2 1 2 3 1 4 Model /A /B A E E B 3 2 1 1 BK BR BR BR BR BR BR BL BL BL BL BL BL BL BL BL RS232C DIO RS485 FG
15 FG Power supply connector (IEC60320,C14) E PE HEA100 1 2 Specifications Continued 2.4 Connector Specifications Power supply voltage 1 AC100V 1-2 Signal connector Note: Always use shielded cable connected to this connector.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.
7 + + + + + + 8 I/O (NPN/PNP) 9 10 FG () 12 - 3.3. 1LECA6 2DIN LECA6D 13 - 3.4. 1 DIN 2 LECA6 DINLECA6D DIN 2M4 DIN DIN A DIN ADIN 2 M4 M4 14 - D (100 ) 2mm 2 D 3 40 30mm 50mm ()60mm 0mm (LE)10mm 25 LEH () 30mm 60mm 30mm 50mm DIN ) 15 - 4.
+ + + + 8 I/O (NPN/PNP) 9 10 FG () 12 - 3.3. 1 LECP6 2 DIN LECP6D 13 - 3.4. 1 DIN 2 LECP6DINLECP6DDIN 2M4 DIN DIN A DIN ADIN 2 M4 M4 14 - D (100 ) 2mm 2 D 3 40 30mm 50mm ()60mm () 0mm (LE)10mm LEH 25 30mm 60mm 30mm 50mm DIN ) 15 - 4.
FG Terminal Grounding terminal Caution (1) 0V line of the gateway unit and the motor controller (LEC) have to be common. (2) When conformity to UL is required, the electric actuator and controller should be used with a UL1310 Class 2 power supply. 6.2 Power line Power lines are prepared by customer.
CN2TB/PC () 19 - .CN4 6.1 1 EMG+ EMG 2 EMGEMG 3 24V 5 4 3 2 () 4 0V 5 FG FG (LEC)(0V) ULUL1310Class2 6.2 2) AWG20(0.5mm (24V0V) 60 2) EMG AWG20(0.5mm (EMG+,EMG-) 60 8mm 20 - D(100) D 6.3 (CN2SW)ON(EMG+,EMG-) (LEC)EMG (CN2SW) RY CN4 CN2 EMG+ EMG24V 0V (CN2SW)ON EMG+,EMG-(LEC) OFF (LEC)(EMG+,EMG-) 21 - (LEC) ( LEC6) DC24V 0V Ry EMG+ Ry EMG(1) BK RLS EMG Ry C 24V 24V
FG Terminal Grounding terminal Caution (1) 0V line of the gateway unit and the motor controller (LEC) have to be common. (2) When conformity to UL is required, the electric actuator and controller should be used with a UL1310 Class 2 power supply. 6.2 Power line Power lines are prepared by customer.
FG LEC UL , UL1310 Class2 62 AWG20 (24V0V) 60 EMG AWG20 EMG+,EMG60 8mm 23 - D (100 ) D 63 CN2SW(EMG+,EMG-) LECEMG CN2SW RY CN4 CN2 EMG+ EMG24V 0V CN2SW EMG+,EMG-(LEC) (LEC)EMG+,EMG-OPEN 24 - (LEC) LEC6 (DC24V 0V ) Ry EMG+ Ry EMG(1 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (2 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V (3 ) BK RLS EMG Ry C 24V 24V M 24V 0V 0V LECOFF
FG Terminal Grounding terminal Caution (1) 0V line of the gateway unit and the motor controller (LEC) have to be common. (2) When conformity to UL is required, the electric actuator and controller should be used with a UL1310 Class 2 power supply. 6.2 Power line Power lines are prepared by customer.
Fault of the SI unit or input block -25No.EX-OMP0025-A Specifications Specifications General specification Item Specifications Ambient temperature 5 to 45 oC Ambient humidity 35 to 85%RH (no condensation) Storage temperature -20 to +60 oC Withstand voltage 500 VAC, 1 minute, Between whole external and FG Insulation resistance 500 VDC, 10 M or more, Between whole external and FG Operating
If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the product is connected to the commercially available switching power supply, switching noise will be superimposed and the product specifications will not be satisfied.
Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met.
FG Connect the grounding cable. 24V Connect the power supply cable 24 VDC for solenoid valve. 0V Connect the power supply cable 0 VDC for solenoid valve. N.C. Blank terminal -11No.EX-OMC0002-C Wiring for communication cable There are two methods of CompoBus/S slave connection, T branch type and Multi drop type.
B RATE Terminal board Terminal Connected to MS+ BS+ of communication power line BDH BDH of communication line BDL BDL of communication line BSBSof communication power line FG Ground line 24V 24V of solenoid valve power line 0V 0V of solenoid valve power line M3 terminal screw in use. EX##-OMF0012 8 EX##-OMF0012-A No.EX-OMF0012-B -9- 5-3. Address setting (1) ADDRESS NO.
If a commercially available switching power supply is used, be sure to ground the frame ground (FG) terminal. If the switching power supply is connected for use, switching noise will be superimposed and it will not be able to meet the product specifications.