SMC Corporation of America
Elite Part Number Search
Search Results "SV1000-50-2A-N1"

connector LO 110 VAC 50/60Hz 5000mm 50 3 With lead wire M [115 VAC 50/60Hz] M plug connector Without lead wire MN 220 VAC 50/60Hz 4 Without connector MO [230 VAC 50/60Hz] Without connector cable WO M8 connector For type "W", DC voltage is only available.

/2000/3000/4000 Series SV1000/2000/3000/4000 Series SV1000/2000/3000/4000 Product is CE compliant with standard part number.

resolution is 1048576 [Pulse/rev] P Travel amount per 1 command pulse [m] n1/n2 Pulley ratio *1 Ex.)

N.O. 13.5 SYA 12 NC 26.2 65.2 58.2 3R 58.2 27 50 50.1 65.2 SYJA 1P 26.2 NO 12 VZA 1/4 1(P), 3(R) port 1/8 (Pitch) P = 27.5 12(PA) port 28 M5 x 0.8 (Breathing hole) VFA 7.5 L2 L1 VFRA (Station n) (Station 1) 1/8 12(PA) port VPA4 12 SYJA 73.5 54 VZA 37.5 11 2A 2A VTA 1/4 2(A) port (Pitch) P = 27.5 28 VGA 2 stations 83.5 68.5 111 96 138.5 123.5 166 151 193.5 178.5 221 206 248.5 233.5 276 261

SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.

block assembly (Standard): SX3000-51-2A The following columns shall be filled in by SMC.

60 50 100V AC Hz 110V AC Hz 200V AC Hz 220V AC Hz Closed center Exhaust center Pressure center 60 50 60 M5 X 0.8: 1.8(0.1) 50 60 (1) AC Push-turnlocking slotted style With light and surge voltage suppressor SYJ5000 Rc(PT)1/8: 4.5(0.25) SYJ7000 Rc(PT)1/8, 1/4: 12.6(0.7) Note 1) All AC voltage models have built-in surge voltage suppressor. 1.2-2 Series SYJ3000/5000/7000 Manifold Variations

resolution is 1048576 [Pulse/rev] P Travel amount per 1 command pulse [m] n1/n2 Pulley ratio *1 Ex.)

/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Body Option Pilot type 0 1 Standard Direct manual override R Internal pilot External pilot Nil Option How to Order Pilot Valve Assembly Option SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC

/60 Hz L plug 25 2500 mm LN Without lead wire 2 200 VAC 50/60 Hz connector 30 3000 mm LO Without connector 110 VAC 50/60 Hz 50 5000 mm 3 M With lead wire [115 VAC 50/60 Hz] M plug MN Without lead wire 220 VAC 50/60 Hz connector 4 MO Without connector [230 VAC 50/60 Hz] W0 Without connector cable M8 connector For type W, DC voltage is only available.

1 N1 1 N1 11221122112211222 N2 2 N2 2 N2 2 N2 MHZ2-10D MHZ2-16D MHZ2-20D MHZ2-25D 1 N1 MHZ2-10D MHZ2-16D MHZ2-20D MHZ2-25D Specifications and dimensions other than the above are the same as the basic type (including narrow type).

1.19 7/16-20 7/16-20 73.7 mm 53.0 mm 19.0 mm 30.2 mm UNF-2A UNF-2A B Hex 2 Hex 1 PS610503-6-6 3.11 2.18 .88 1.31 9/16-18 9/16-18 78.9 mm 55.2 mm 22.2 mm 33.3 mm UNF-2A UNF-2A Port 2 PS810503-8-8 3.34 2.38 1.12 1.50 3/4-16 3/4-16 84.9 mm 60.3 mm 28.6 mm 36.5 mm UNF-2A UNF-2A Port 1 PS810503-10-10 3.50 2.48 1.12 1.50 7/8-14 7/8-14 88.9 mm 62.9 mm 28.6 mm 36.5 mm UNF-2A UNF-2A PS1210503-12-

Nil Applicable blanking plate assembly SYJ300-10-2A 02 2 stations Pilot valve is on the A port side.

GA pin CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com KK UNF 2A KK UNF 2A FF UNF 2A D across flats NN mounting nut (included) D across flats LB + ZC per 1" of stroke MB LB + ZC per 1" of stroke NN mounting nut (included) NN UNF 2A (in) MB1 Bore size (in) MM KK

Therefore, also check the allowable load for the selected conditions. 6.1 10 16 20 25 32 40 MX 0.8 6.1 1.1 0.8 6.1 10.8 3.7 10.8 4.9 3.7 10.8 40 50 40 50 40 50 17.6 MTS 11 17.6 16 11 17.6 MY1H 27.5 23 27.5 26 23 27.5 30 30 30 39.2 MY 39 39.2 50 39 39.2 20 50 39 50 50 50 50 20 20 CY The above values are the maximum allowable values for moment and load.

Therefore, also check the allowable load for the selected conditions. 10 16 20 25 32 40 0.8 1.1 0.8 6.1 6.1 6.1 3.7 4.9 3.7 10.8 10.8 10.8 11 16 11 17.6 17.6 17.6 MY1H 23 26 23 27.5 27.5 27.5 39 50 39 39.2 39.2 39.2 50 50 39 50 50 50 The above values are the maximum allowable values for moment and load.

Type 41 (5 Port/Base mounted) How to Order Applicable blanking plate assembly SYJ7000-21-1A SS5YJ741 05 01 01 1/8 A, B port size Thread type Stations P port 1/4 + + 02 2 stations Applicable individual EXH spacer assembly SYJ7000-17-2A Nil F N T Rc G NPT NPTF : B : R P R 20 20 stations A A, B port R port 1/4 B Applicable individual SUP spacer assembly SYJ7000-16-2A Note) For more than 8 stations

1 VVFS5000-2A-1 VVFS5000-2A-2 End plate (U side) assembly !

ZPT ZPR XT661 XT661 735 Non-contact Gripper XT661 Series How to Order Specifications Cyclone type 2A 4A 6A 8A 10A XT661 2A R Outer body diameter (mm) 20 40 60 80 100 Piping port size M5 x 0.8 Rc 1/8 Fluid Air* Outer body diameter: Operating pressure 0.01 to 0.5 MPa 2A 20 mm 4A 40 mm 6A 60 mm 8A 80 mm 10A 100 mm Proof pressure 0.75 MPa Ambient and operating temperature 5 to 60C (no freezing