SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-42-03-N7"

KQ2 KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 3/8

(42) AS32l1FG-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS32l1FG-03-06(S)A 6 10.4 21.8 32.1 36.4 50 48.4 44.5 42.9 1/4 19 16.6 13.3 29 (30) AS32l1FG-03-08(S)A 8 13.2 22.7 33 14.2 AS32l1FG-03-10(S)A 10 15.9 26.7 37 28 15.6 30 (31) AS32l1FG-03-12(S)A 12 18.5 29.7 40 26.8 17 32 (33) AS42l1FG-04-10(S)A 10 1/2 24 (23.8) 10.4 21.8 32.1 28.7 42.3 40.7 37.1 35.5 3/8 19 16.6 15.9 18.8 27.4 40.3 (

04 03 04 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: 3/8 04: 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type Individual EXH spacer 179 (plug-in type) 133 (plug lead type) VVQ5000-R-1T (Plug-in type) VVQ5000-R-5T (Plug lead type) 03 04 03 04 32 16 By mounting individual

Temperature sensor Remote type 3-color display Digital flow monitor CAT.ES100-80C Series PF3W IP65 Digital Flow Switch for Water 40% 40% smaller than existing product Reducing piping space PF3W704-03 66.4 70 Shortened PF2W704-03 (Existing product) 30 50 Straight piping length PF3W704 42 PF2W704 Existing product requires a straight piping length at least 8 times the piping diameter.

RUSSIA SMC Pneumatik LLC. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2004 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing IW printing IW 120DN Printed in Japan D-DN This catalog is printed on recycled paper with

04 03 04 VVQ5000-P-1(Plug-in type) VVQ5000-P-5(Plug lead type) 179 (Plug-in type) 133 (Plug lead type) 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: Rc 3/8 04: Rc 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug llead type Individual EXH spacer 03 04 03 04 VVQ5000-R-1(Plug-in

-20 IS1000M-30 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 IS1000M-60 IS1000M-60 Y21001 (02) Y310-(01) 02 Y310-(01) 02 Y410-(02) 03 Y510-(02) 03 Y61003 (04) 06 (10) Y610(03) 04 (03) 04 Y610Note 5) Note 6) VHS40-06 02 03 04 E600VHS2001 02 02 03 02 03 VHS30VHS30VHS40VHS50Note 6) E30002 03 04 E30002 03 04 E40002 03 04 06 E500-06 E20001 02 03 Note 6) 06 10 06 10 E60006 10 E600E100-M5 02 03 04

YA-03 Joint . YU-03 T1 B 2-D through 2-O counterbore (mm) Bore size (mm) B D E J M O Part No. 12 7 25 9 34 11.5 depth 7.5 YB-03 32, 40 12 9 32 11 42 14.5 depth 8.5 YB-05 50, 63 Joint Weight (g) Bore size (mm) T1 RS T2 V W Part No.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com YA 03 YA-03 YA-05 10 12 6.5 6.5 42 50 6 8 16 20 6.8 9 18 20 Applicable air cylinder bore Bore size (mm) 32, 40 50, 63 W V U Weight (g) Part No. 03 05 32, 40 50, 63 Mounting bracket YA-03 YA-05 55 100 56 67 18 22 6 8

16 59 108 139 63 25 to 800 M8 x 1 9 M27 x 2 46 33 12 198 36 77 32 58 36 66 19 30 38 31 13 1/2 69 50 18 74 115 153 80 25 to 800 10.5 M33 x 2 57 32 15 223.5 M10 x 1.25 45 96 41 75 45 74 13 41 35 42 17 1/2 77 60 17 80 133 168 100 25 to 1000 14.5 M42 x 2 58 42 15 257.5 M14 x 1.5 56 115 52 90 56 86 16 50 41 38 19 3/4 79 72 22 97 146 187 Transaxial foot: CHSDLA PJ + Stroke Y J MM S + Stroke H

For driver of 200W to 400W, regenerative resistor is not used. 02:LEC-MR-RB-032 03:LEC-MR-RB-12 Selection of regenerative option 00: Regenerative option is not used For servo amplifier of 100W, regenerative resistor is not used. For servo amplifier of 200 to 400W, built-in regenerative resistor is used. 02: MR-RB032 03: MR-RB12 4 6 4.

PFM7-C4/C6/C8/N7--X693 PFM7S-C4/C6/C8/N7--X693 PFM7-01/02--X693 PFM7S-01/02--X693 -73No.PF-OMJ0006-J PFM7-C4/C6/C8/N7--X694 PFM7S-C4/C6/C8/N7--X694 PFM7-01/02--X694 PFM7S-01/02--X694 -74No.PF-OMJ0006-J For a mixture of Argon (Ar) and carbon dioxide (CO2) The mixture ratio can be selected from Ar : CO2 = 92 : 8, 90 : 10, 80 : 20, 70 : 30 or 60 : 40.

-06A 01-A E200-02-A 03-A 02 E300-03-A 04 E500-06-A Piping adapter Note 3) 01-A IS10E-2002-A 03-A 02-A IS10E-3003-A 04-A Pressure switch with piping adapter Note 3) Y54-03-A 04-A Y24-01-A 02-A Y34-01-A 02-A Cross spacer Note 3) Note 1) in part numbers for a round pressure gauge indicates a type of connection thread.

Applicable for the ZP series adapter How to Order ZP2 03 U N Pad unit Pad diameter Pad material Symbol Pad diameter Blast type Symbol Material NBR Silicone rubber Urethane rubber FKM Conductive NBR Conductive silicone rubber 03 B04 05 06 B06 07 B08 N S U F GN GS 3 4 5 6 6 7 8 Blast type: Work pieces can be removed easily.

AXT620-32-1 (M4 x 48, With spring washer) For mounting valve M4: 1.4 Nm 1509 VFA3000/5000 Series Dimensions: VFA3000 Series/Base Mounted 2 position single VFA3140(-P) 02 03 2 position double VFA3240(-P) 02 03 28 33 28 33 1/4, 3/8 [4 (A), 2 (B) port] 1/4, 3/8 [4 (A), 2 (B) port] 13 13 22 22 1/8 (Pilot port: Upward) 81 1/8 (Pilot port: Upward) 46 20 36 36 20 46 4A 2B 4A 2B 26.4 26.4 35 42

03 CB CT CH TZ Applicable bore (mm) Applicable pin O.D.

U D U D Kit/Electrical entry/Cable length F L Cylinder port kit (D-sub connector) kit (Lead wire cable) 03 04 B CM Rc 3/8 Rc 1/2 Bottom ported Rc 1/2 Mixed Note) Note)In case of mixed specification, indicate on the manifold specification sheet. .

Name plate [-N7] VVQ1000-N7-Station (1 to Max. stations) When ordering assemblies incorporated with a manifold, suffix -N to the manifold no. It is a transparent resin plate for placing a label that indicates solenoid valve function, etc. Insert it into the groove on the side of the end plate and bend it as shown in the figure.

-03 04 AS420-03 AN30-03 12 x 1 m D AS420-04 AN40-04 SGP15A x 1 m 1723 3 Port 3 Position Valve Body Ported VEX3 Series How to Order Air operated Pilot solenoid VEX3 B 12 0 01 1 Air operated VEX3 D B 5 1 12 2 01 Pilot solenoid Operation type Option 1 External pilot solenoid 2 Internal pilot solenoid Nil None Thread type Nil Rc F G N NPT T NPTF Body size Port size B Bracket (VEX312 only) Body

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 2009 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing NT printing NT 6000SZ Printed in Japan.