As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
As the circulating fluid temperature is within the set range of "AS.06", "AS.06" alarm monitoring starts. Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts.
Step Request data Response data Operation details 1 01 06 0412 000A 01 06 0412 000A Sets Step Data No. 1 Positioning time to 0.1 sec. 01 10 0410 0002 2 01 10 0410 0002 Sets Step Data No. 1 Target position to 10 mm. 04 0 2710 (4) Return to Origin Change the Card Motor controller (controller ID1) operation mode to serial operation, and send a Return to Origin instruction.
43 53 43 ZC(D)UKD32 ZC(D)UKR32 ZP 29 34 38 18.5 19.5 60.5 65.5 69.5 50 51 Note) ZPU-X11: Flat type only.
(Example, KQ2H 06-02-X12) Specification Dimension How to Order Stainless steel One-touch fittings 2 For use in highiy corrosive atmospheres where brass is not acceptable. Specification Dimension Same as KQ2 series. Same as KQ2 series.
Passage Porting specifications Symbol 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common 1 Non Plug-in Type: Stacking Type Manifold Base Wiring for every valve VV5ZS2 C4 06 51 1 Thread type Series VZS2000 Manifold Standard Nil NPT Rc N T F Non plug-in type Stacking type manifold base NPTF G Option Port size Rc 1 8 01 Embedded type One-touch fitting Applicable tubing O.D.: 4 Stations C4 02 2
43 43 22 27 27 32 41 14 14 14 15 17 17 21 21 16 16 18.5 15 17 17 21 21 16 16 18.5 11 11 11 11 11 16 16 18.5 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 M14 x 1.5 M14 x 1.5 M16 x 1.5 6 7 7 11 11 15 15 17 14 18 18 22 26 31 31 36 Note) In installing an air cylinder, if a hole must be made to accommodate the rod portion, make sure to machine a hole that is larger than
How to Order Integrated Display Type H PF2A7 Flow rate range Unit specification High flow rate type Wiring specification 150 to 3000l/min 300 to 6000l/min 600 to 12000l/min 03 06 12 Nil M With unit switching function Fixed SI unit Note) Port specification Nil N 3m lead wire with connector Without lead wire Nil N F Rc NPT G Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l,
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Black White Load (41.5) OUT2 2 ZSP + 12 to 24 VDC 3 Load ISA2 Blue PF2A7--67(-M) IS 4 42 ZSM PF2 2-3.4 IF 43 Flow direction Data PF2A711/721/751 64 23 116 1.6 88 Connector pin numbers 4 3 FLOW SWITCH U P 34 54 44 SET OUT1 OUT2 DOWN 2 1 FOR AIR Pin no
How to Order Integrated Display Type PF2A7 H M Flow rate range Unit specification High flow rate type 03 06 12 150 to 3000 l/min 300 to 6000 l/min 600 to 12000 l/min Lead wire (Refer to page 35.)
How to Order Integrated Display Type H PF2A7 Flow rate range Unit specification High flow rate type Wiring specification 150 to 3000l/min 300 to 6000l/min 600 to 12000l/min 03 06 12 Nil M With unit switching function Fixed SI unit Note) Port specification Nil N 3m lead wire with connector Without lead wire Nil N F Rc NPT G Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l,
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB DBT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 -X BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
CDV3, CDVS CE2, CNA CDL1 CDS1 MDB, MDBB BT -04 BT -04 BT -06 BT -08 BT -08 BT -12 BT -12 BT -16 BT -18A BT -20 BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 [Mounting screws set made of stainless steel] The following set of mounting screws made of stainless steel is also available. Use it in accordance with the operating environment.
Specified layout Note 2) (Available up to 32 solenoids) 20 20 stations Symbol A, B port P , E port A, B port size (Metric) Symbol A, B port P , E port A, B port size (Inch) Applicable series Applicable series C3 C4 C6 C4 C6 C8 C6 C8 C10 M N1 N3 N7 N3 N7 N9 N7 N9 N11 M 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting
74 59 155 143 128 3/4, 1 74 46 06 10 06 10 90 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 107 06 10 94 M6 x 1 Depth 7.5 39 50 0 77 74 59 175 128 3/4, 1 46 06 10 111 14-3-9 10 Series AV2000/3000/4000/5000 Connecting Spacer for Modular Style F.R.L.
39 44 88 39 78 63 48.5 43 50 95 43 85 80 56 51 57 104 59 51 93.5 100 63.5 58.5 65 114 70 58.5 104 102
U U side (2 to 10 stations) D D side (2 to 10 stations) B Both sides (2 to 20 stations) 16 16 stations 02 2 stations Specified layout Note 2) (Available up to 32 solenoids) 20 20 stations A, B port size (Metric) A, B port size (Inch) Symbol A, B port P, E port Applicable series C3 3.2 One-touch fitting 8 One-touch fitting SV1000 C4 4 One-touch fitting C6 6 One-touch fitting C4 4 One-touch