Elbow Universal 2 3 Metric size Inch size 3.2 23 01 1/8" 04 06 08 10 12 03 05 07 09 11 13 4 5/32" 6 3/16" Control 8 1/4" Meter-out Meter-in 0 1 10 5/16" 12 3/8" Use 1/8" tube. 1/2" M5 Port size With One-touch fitting M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 01 02 03 04 U10/32 N01 N02 N03 N04 Needle Valve/Flow Characteristics AS1201FG, AS1211FG AS2201FG-
How to Order G LG1 05 1 Cable length 05 5m Compatible models G R Y Matsushita Electric Industrial Co., LTD Mitsubishi Electric Corporation Yaskawa Electric Corporation Cable compatibility table Model Manufacturer's No.
(Same side) A HS Number of switches 20 25 32 40 50 63 80 100 31.5 26 24 Mounting surface Port surface Port surface Port surface 31.5 28.5 24 32.5 33 25 37 36.5 28 45.5 42 36 45.5 48.5 36 Switch type 56 57.5 46 Minimum stroke (mm) 10 15 75 57 68 46 15
Series CRJ Mini-rotary Actuator Rack & Pinion Style Size: 05, 1. Features. Series Variations. Precautions. Series CRJ Mini-rotary Actuator Rack & Pinion Style. How to Order . Specifications. Construction. Dimensions . Series CRA1 Rotary Actuator Rack & Pinion Style Size: 30, 50, 63, 80, 100 . Series Variations. Series CRA1 Rotary Actuator Rack & Pinion Style Size: 30, 50, 63, 80, 100 .
32.5 15 4 4 4 4 9 30 163 213 52 38 17 4 6 4 5 10.5 37 179 244 65 46.5 24 5 6 4 9 12 37 194 259 75 56.5 24 5 8 4 11.5 14 46 218 300 95 72 30 5 8 4 17 15 51 233 320 114 89 32 5 1.8-9 Series CP95 Dimensions mounting accessories L, F, C and D [mm] Mounting type L STROKE STROKE Mounting type F Rear mounting STROKE Front mounting Mounting type C Mounting type D STROKE Bore 1.8-10 ISO/VDMA
Mr=W (L3 + C) = 10 (.05 + 0.014) =0.64 [N m] W Mr 2 =Mr/Mr max. =0.64/12 =0.053 Mr: Mr max. value is from
Trouble shooting . 46 9.1 Alarm and Warning . 46 9.3 Alarm Display . 46 -2- LECS Series / Driver Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
AXT620-32-1 (M4 x 48, With spring washer) For mounting valve M4: 1.4 Nm 1509 VFA3000/5000 Series Dimensions: VFA3000 Series/Base Mounted 2 position single VFA3140(-P) 02 03 2 position double VFA3240(-P) 02 03 28 33 28 33 1/4, 3/8 [4 (A), 2 (B) port] 1/4, 3/8 [4 (A), 2 (B) port] 13 13 22 22 1/8 (Pilot port: Upward) 81 1/8 (Pilot port: Upward) 46 20 36 36 20 46 4A 2B 4A 2B 26.4 26.4 35 42
Auto switch mounting band D-B54 BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) DNote 1) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform, methylamines, hydrochloric acid or sulfuric acid is splashed over, so it cannot be used. Please contact SMC regarding other chemicals.
AN200 to 900 1 Model 0.5 A B D Dimensions (mm) Model Port size R Weight (g) Recommended flow (m3/min (ANR)) 3 or less 5 or less 8 or less 12 or less 20 or less 30 or less 50 or less 80 or less Effective area (mm2) 35 60 90 160 270 440 590 960 2 0.2 Inlet pressure (MPa) Noise level (dB) (A) 0.1 1 4 AN200-02 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233
(Default) Spare (SW2-2) Rotary axis setting switch (SW1) Description Display 0 Axis No.1 01 1 Axis No.2 02 2 Axis No.3 03 3 Axis No.4 04 4 Axis No.5 05 5 Axis No.6 06 6 Axis No.7 07 Down 7 Axis No.8 08 (Be sure to set to the 8 Axis No.9 09 "Down" position.) 9 Axis No.10 10 A Axis No.11 11 B Axis No.12 12 C Axis No.13 13 D Axis No.14 14 E Axis No.15 15 F Axis No.16 16 -12- 5.
(Station n) (Station 1) VVEX4-1 (Internal pilot) 83.3 A A 62.8 47.5 P R 13.5 38.5 P=46 n x Port 2(A): 1/4, 3/8 L Dimensions L1=46n+31, L2=46n+15 n: Stations Station L dimension 2 3 4 5 6 L1 123 169 215 261 307 L2 107 153 199 245 291 1736 VEX3 Series Specific Product Precautions 1 Be sure to read this before handling the products.
Calle 18 69-05 Apart. Aereo 081045 Santa Fe de Bogot, Colombia TEL: 1-424-9240 FAX: 1-424-9260 14-21-20
Tube Thread NPT Hex Part Number Weight (grams) Bag/Box Quantity D1 D2 D3 L1 L3 P Q 1/4 1/4-18 19.00 KV2UD07-35S 15.2 17 3.5 46 100/200 17.9 18.1 57.5 25.0 30.6 15.2 12.1 51.7 12 Series KV2 Union Double Y KV2UD_ _-_ _ P Applicable Tube A (x4) MA L2 D1 L1 4.2 L3 MB 8 Q Applicable Tube B L3 D2 D3 L2 Min. Flow Dia.
D.8 AR3001 1/4 3/8 53 127.5 35 53 29.5 41 2.3 40 46 6.5 8 53 52.5 36
5m 10 10m 15 15m 20 20m C A B CD E F G () 25 7-1 AA BB CC DD EE HA KA KB KK 9 45.5 5.5 M5x0.8 9.5 69 30.5 16 M6x1 11 54 6.5 M6x1 12 84 32 15 M8x1.25 14 64 8.5 M8x1.25 12 102 41.5 19 M10x1.5 R S T U V W X Y Z 22 63.5 23.5 22 41 16 9 30 34.5 26 77.5 32.5 27 56 19 10 37 42 37.5 95 50.5 35 68 23 23 45 51 I J K L M N O P Q 76.5 40 46 28 11 14.5 28 15 16 91 46.5 58 32 15 16 30.5 16 21.5 110 55
Bore size (mm) 32, 40 50, 63 80, 100 Bore size (mm) 32 40 50 63 80 100 Mounting bracket BT-03 BT-05 BT-06 (1) MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 Foot A set of following stainless steel mounting screws is attached. (A mounting bracket itself is not attached. Please order it separately.)
Bore size (mm) 32, 40 50, 63 80, 100 BT-06 Bore size (mm) 32 40 50 63 80 100 Mounting bracket BT-03 BT-05 (1) Foot MB-L03 MB-L04 MB-L05 MB-L06 MB-L08 MB-L10 A set of following stainless steel mounting screws is attached. (A mounting bracket itself is not attached. Please order it separately.)
See pages 40-46 lor more informalion on Sl\4C's LC6 series drivers. Eolt I trlax. tightening deptn (anm) LXS [,46x1 7.4\75.5) 1 0 ACaution Boll should be a1 least 0.5mm shorler lhan the max. tighleninq deplh lo prevent boltfrom pressing lhe body.