(Tolerance 30%) 5.3-11 Reed Switch/Band Mounting D-A33/D-A34/D-A44 Applicable Actuator Series Terminal conduit: D-A3 DIN terminal: D-A4 Series Bore size (mm) CDA1, CDBA1, CDV3, CDVS, CDLA, 40, 50, 63, 80, 100 CE2, CNA CDL1 40, 50, 63, 80, 100, 125, 140, 160 CDS1 125, 140, 160, 180, 200 RHC 20, 25, 32, 40 Specifications PLC: Programmable Logic Controller D-A3 (With indicator light) Terminal

(mm) Auto switch model Bore size 50 63 80 100 125 32 40 D-A3/A44 D-G39/K39 BMB2-040 BMB1-050 BMB1-063 BMB1-080 BMB1-100 BMB2-032 BS1-125 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5F D-F5BAL D-F5NTL BT-03 BT-03 BT-05 BT-05 BT-06 BT-06 BT-08 D-P5DWL D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W D-Y7WV D-Y7BAL BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080 BAP2T-080 BMB4-032 BMB4-050 BMB4-050

(5.7) 15 16 11 30.7 114 [820m] A B-1 2 A A-1 1 L B B-2 6 B A-2 5 8 8m COM-A/COM B-3 3 COM-B/ A-3 4 A 10m B 15m Shield Vcc B-4 12 C 20m GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 4 B-1 5 A-1 1 B-3 2 A-3 2 1 (5.5) 14 18 (6.3) B1 A1 5 6 17.7 14.2 A6 B6 B1 A1 10.2 2 1 B3 A3 (5.7) 15 16 11 30.7 45 - 115 I/O No.

NPN Type PNP Type I/O signal power I/O signal power CN5 CN5 24VDC 24VDC A1 COM A1 COM A2 COM A2 COM A3 IN0 A3 IN0 A4 IN1 A4 IN1 A5 IN2 A5 IN2 A6 IN3 A6 IN3 A7 IN4 A7 IN4 A8 MODE A8 MODE A9 SETUP A9 SETUP A10 HOLD A10 HOLD A11 DRIVE A11 DRIVE A12 RESET A12 RESET A13 SVON A13 SVON B1 OUT0 Load B1 OUT0 Load B2 OUT1 B2 OUT1 Load Load B3 OUT2 B3 OUT2 Load Load B4 OUT3 B4 OUT3 Load Load B5 OUT4

Auto Switch Specifications Terminal conduit: D-A3 DIN terminal: D-A4 PLC: Abbreviation of Programmable Logic Controller D-A3 (With indicator light) Terminal conduit RE A B D-A33 D-A34 Auto switch model Applicable load PLC Relay, PLC REC Load voltage 24 VDC 100 VAC 24 VDC 200 VAC (2) Load current range 5 to 50 mA 5 to 25 mA 5 to 50 mA 5 to 12.5 mA CX Contact protection circuit None Built-in

Auto Switch Specifications Terminal conduit: D-A3 DIN terminal: D-A4 PLC: Abbreviation of Programmable Logic Controller D-A3 (With indicator light) Terminal conduit CJ1 D-A33 D-A34 Auto switch model Applicable load PLC Relay, PLC CJP Load voltage 24 VDC 100 VAC 24 VDC 200 VAC (2) Load current range 5 to 50 mA 5 to 25 mA 5 to 50 mA 5 to 12.5 mA CJ2 Contact protection circuit None Built-in

Auto Switch Specifications Terminal conduit: D-A3 DIN terminal: D-A4 PLC: Abbreviation of Programmable Logic Controller D-A3 (With indicator light) Terminal conduit CL D-A33 D-A34 Auto switch model Applicable load PLC Relay, PLC CL1 Load voltage 24 VDC 100 VAC 24 VDC 200 VAC (2) Load current range 5 to 50 mA 5 to 25 mA 5 to 50 mA 5 to 12.5 mA MLGC Contact protection circuit None Built-in

W W Mey Mep We We L3 A3 L2 A2 Note) Static moment : Moment by gravity Kinetic moment : Moment by stopper collision Max.allowable load:W max.

NPN type -PNP type Input signal power Input signal power CN5 CN5 supply supply 24 VDC 24 VDC A1 COM A1 COM A2 IN0 A2 IN0 A3 IN1 A3 IN1 A4 IN2 A4 IN2 The power supply can be either polarity. The power supply can be either polarity.

A2 Bracket B (Option unit part no.: ZS-38-A2) 42.5 (A) A3 Bracket C (Option unit part no.: ZS-38-A3) Bracket configuration allows mounting in four orientations. 30 1.6 25 20 20 45 30 5.2 5.5 5.2 9.1 13.6 A B 41.4 16.4 Bracket B B 7.5 7.2 53 28 Bracket C 20 When using the bracket B or C, install it by taking the dimensions of the piping part into consideration. 38 2-Color Display High-Precision

My = 1 x 9.8 (10 + 30)/1000 = 0.39 A3 = 30 May = 1 x 1 x 18 = 18 Mymax = 18 K = 1 = 1 2 = 0.39/18 = 0.022 Examine Mr. Mr = 1 x 9.8 (30 + 10.5)/1000 = 0.39 A6 = 10.5 Mar = 36 Mrmax = 36 K = 1 = 1 '2 = 0.39/36 = 0.011 Find the static moment M (Nm).

A3 The power A4 A4 The power supply can be either polarity. supply can be either polarity.

100 10 ) JIS B 8392-1 11.1.21.6.2:2003 () -5No.PS-OML0002CN-G * / / ,FG (35N ) () () * () 6 33 () () 10 m DC(-)() () * -6No.PS-OML0002CN-G ( ) () CE 050(5), * ON , 1015 10 /1 2146 LCD * -7No.PS-OML0002CN-G 01 N ISE30A 3 ISE30A -0.11 MPa Y ZSE30A 0-101 kPa ZSE30AF -100100 kPa K T 2 01 R1/8(M5) N01 NPT1/8 (M5) A1 A C4H 4mm5/32 inch C6H 6mm A2 B NH7 1/4 inch N7H A3

Speed with no load (mm/s) 33 or m ore 100 or m ore 200 or m ore Speed with no load (mm/s) 33 or m ore 100 or m ore 200 or m ore L[]ZB[]3L[][][]A3 L[]ZB[]3M[][][]A3 L[]ZB[]3H[][][]A3 L[]ZB[]5L[][][]A5 L[]ZB[]5M[][][]A5 L[]ZB[]5H[][][]A5 Rated thrust (N) 196 or m ore 117 or m ore 72 or m ore Rated thrust (N) 80 or m ore 43 or m ore 24 or m ore electric cylinder LZ series and the directional

Function micro COM Input Common 6 1 S-1 1 S-11 +24V IN0001 General-purpose input 1 B3 7 2 S-1 2 S-12 GND IN0002 General-purpose input 2 A3 32 3 S-1 3 S-13 Valve ON/OFF(Finger opening side) IN0003 General-purpose input 3 B4 8 4 S-1 4 S-14 Valve ON/OFF(Finger closing side) IN0004 General-purpose input 4 A4 33 5 S-1 5 S-15 Auto switch (Finger opening direction) IN0005 General-purpose input 5

B B-6 8 B A-6 3 (14.2) (2) 2 1 5.5 (18) (14) A1 B1 1 6 5 17.7 (3) 2 1 A6 B6 6.3 16 15 30.7 L (11) 59 - 15.3 [5m ] LE-CP--B(1) 2 A B-1 2 L A A-1 1 B B-2 6 B A-2 5 COM-A/COM B-3 3 COM-B/ A-3 4 3 Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 9 B A-6 8 3 (4) + B-1 4 A-1 5 + B-3 1 A-3 2 8 (14.2) 1 2 (2) B1 A1 17.7 1 (14) A6 B6 5 6 10.2 (3) 1 2 A1 B1 (18) 5.7 A3

1 (18) A6 B6 (6.3) 15 16 (11) (30.7) -58- 14.3 ()[5m ] (1) (2) LE CP B A B-1 2 A A-1 1 (L) B (B-2) 6 B (A-2) 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 (3) 5 5m Shield Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 B (B-6) 9 B (A-6) 8 3 (4) S 4 (+) B-1 5 (-) A-1 1 (+) B-3 2 (-) A-3 (8) (1) (2) (B1) A1 (14.2) 2 1 (17.7) (14) (18) 6 (10.2) A6 B6 5 (3) B1 A1 2 1 (B3) (A3

) 2 1 (18) B6 A6 ( 6.3) 16 15 (11) (30.7) 66 - 15.3 [5m ] (1) (2 ) ---A B-1 2 L A A-1 1 B (B-2) 6 B (A-2) 5 1 1.5m COM-A/COM B-3 3 3 3m COM-B/ A-3 4 (3) 5 5m Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 B (B-6) 9 B (A-6) 8 3 (4) S 4 (+) B-1 5 (-) A-1 1 (+) B-3 2 A-3 (8) (1) (2 ) (B 1) (14.2) A1 2 1 (17.7) (14) (18) 6 (10.2) A6 B6 5 (3 ) 2 1 B1 A1 (B3 ) (A3

T2 L6 L4 A1 H1 L5 A3 T1 A2 Applicable tubing diameter d A1 A2 A3 D1 D2 H H1 L1 L2 L3 L4 L5 L6 M T T1 T2 Model number 6mm 1/4 1/4 8mm (5/16) 10mm 3/8 12mm 1/2 ASP330F-U01-06-X352 ASP330F-U01-07-X352 ASP430F-U02-07-X352 ASP430F-U02-08-X352 ASP530F-U03-10-X352 ASP530F-U03-11-X352 ASP630F-U04-12-X352 ASP630F-U04-13-X352 45.7 9.4 45.5 G 1/8 51.1 16.1 14 29.3 14 13.7 38.4 22.9 26.9 11.6 14.2 1/